Partial Shading Condition drastically reduces the maximum power output of Photovoltaic array. Partial shading occurs due to several factors such as; flying birds, trees and passing clouds, etc. Many ways can be mitigated partial shading problems in PV array. One among the way is reconfiguration techniques, namely reconfigure the location of PV modules in PV array based on irradiance levels in order to distribute shading effects and increasing maximum power. This paper proposed an optimal SuDoKu reconfiguration pattern for 9 × 9 Total-Cross- Tied PV array to improve maximum power under partial shading conditions. In this approach, the physical location of PV modules in TCT array are rearranged based on optimal SuDoKu style without altering the electrical connections, so that the shading effects can distribute over the array. Further, the performance of proposed pattern investigated with existing SuDoKu pattern under different shading conditions by comparing the Global Maximum Power Point, Mismatch Losses, Fill-Factor and Efficiency using Matlab-Simulink. Based on the results of this paper, it concluded that the proposed optimal SuDoKu reconfiguration arrangement is reducing the line losses and disperse the shading effects over the array as compared to SuDoKu arrangement.
Shade phenomena affect the PV module's power output, introduce multiple peak points in PV characteristics, and shorten the expected life cycle of the module. In order to prevent this issue, PV modules should reconfigure, namely, altering the electrical connections between PV modules based on the irradiance without changing their physical locations. As a result, the shading effects can distribute over the array and increase power output. This paper proposed a novel reconfiguration technique based on the simulated annealing algorithm to distribute shading impacts on 9 9 total-cross-tied (TCT) PV array. In this work, the proposed algorithm produces a reconfigured connection matrix for 9 9 TCT array that can minimize the current differences in each row and improve the power output. Various shading conditions have been taken to investigate the proposed technique by obtained global maximum power point (GMPP), current at GMPP, power loss, fill-factor, and efficiency. Further, the performance of the proposed technique is validated with other existing reconfiguration methods under partial shadings. In comparison with existing methods, the result shows that the proposed simulated annealing enhanced the power generation of the TCT array under all shading patterns.
This work proposed a skyscraper (SS) PV array reconfiguration arrangement for $4\times 4$ TCT array to distribute partial shading conditions (PSCs) and improve the performance using Matlab-Simulink. In this method, the physical location of PV modules in the TCT array is rearranged according to the skyscraper style without modifying electrical connections. In order to investigate the performance of the proposed method, various other existing PV array interconnection schemes have been compared in different shading conditions. Further, the global maximum power point, fill-factor, and efficiency parameters are obtained to assess the performance of each array. The outcome of the paper shows that, relative to other PV arrays under shading conditions, the proposed skyscraper method increases the maximum power.
14 October 2021 in Technology and Economics of Smart Grids and Sustainable Energy