Chronic kidney disease (CKD) is associated with an increased risk for cardiovascular events, hospitalizations, end stage renal disease and mortality. Main risk factors for CKD are diabetes, hypertension, and older age. Although CKD prevalence is about 10%, awareness for CKD is generally low in patients and physicians, hindering early diagnosis and treatment. We analyzed baseline data of 3305 participants with CKD Stages 1–4 from German cohorts and registries collected in 2010. Prevalence of CKD unawareness and prevalence ratios (PR) (each with 95%-confidence intervals) were estimated in categories of age, sex, CKD stages, BMI, hypertension, diabetes and other relevant comorbidities. We used a log-binomial regression model to estimate the PR for CKD unawareness for females compared to males adjusting for CKD stage and CKD risk factors. CKD unawareness was high, reaching 71% (68–73%) in CKD 3a, 49% (45–54%) in CKD 3b and still 30% (24–36%) in CKD4. Prevalence of hypertension, diabetes or cardiovascular comorbidities was not associated with lower CKD unawareness. Independent of CKD stage and other risk factors unawareness was higher in female patients (PR = 1.06 (1.01; 1.10)). Even in patients with CKD related comorbidities, CKD unawareness was high. Female sex was strongly associated with CKD unawareness. Guideline oriented treatment of patients at higher risk for CKD could increase CKD awareness. Patient–physician communication about CKD might be amendable.
Chronic tendon ruptures are common disorders in orthopedics. The conventional surgical methods used to treat them often require the support of implants. Due to the non-availability of suitable materials, 3D-printed polycaprolactone (PCL) scaffolds were designed from two different starting materials as suitable candidates for tendon-implant applications. For the characterization, mechanical testing was performed. To increase their biocompatibility, the PCL-scaffolds were plasma-treated and coated with fibronectin and collagen I. Cytocompatibility testing was performed using L929 mouse fibroblasts and human-bone-marrow-derived mesenchymal stem cells. The mechanical testing showed that the design adaptions enhanced the mechanical stability. Cell attachment was increased in the plasma-treated specimens compared to the control specimens, although not significantly, in the viability tests. Coating with fibronectin significantly increased the cellular viability compared to the untreated controls. Collagen I treatment showed an increasing trend. The desired cell alignment and spread between the pores of the construct was most prominent on the collagen-I-coated specimens. In conclusion, 3D-printed scaffolds are possible candidates for the development of tendon implants. Enhanced cytocompatibility was achieved through surface modifications. Although adaptions in mechanical strength still require alterations in order to be applied to human-tendon ruptures, we are optimistic that a suitable implant can be designed.
Three-dimensional (3D) printing and bioprinting have come into view for a plannable and standardizable generation of implantable tissue-engineered constructs that can substitute native tissues and organs. These tissue-engineered structures are intended to integrate with the patient’s body. Vascular tissue engineering (TE) is relevant in TE because it supports the sustained oxygenization and nutrition of all tissue-engineered constructs. Bioinks have a specific role, representing the necessary medium for printability and vascular cell growth. This review aims to understand the requirements for the design of vascular bioinks. First, an in-depth analysis of vascular cell interaction with their native environment must be gained. A physiological bioink suitable for a tissue-engineered vascular graft (TEVG) must not only ensure good printability but also induce cells to behave like in a native vascular vessel, including self-regenerative and growth functions. This review describes the general structure of vascular walls with wall-specific cell and extracellular matrix (ECM) components and biomechanical properties and functions. Furthermore, the physiological role of vascular ECM components for their interaction with vascular cells and the mode of interaction is introduced. Diverse currently available or imaginable bioinks are described from physiological matrix proteins to nonphysiologically occurring but natural chemical compounds useful for vascular bioprinting. The physiological performance of these bioinks is evaluated with regard to biomechanical properties postprinting, with a view to current animal studies of 3D printed vascular structures. Finally, the main challenges for further bioink development, suitable bioink components to create a self-assembly bioink concept, and future bioprinting strategies are outlined. These concepts are discussed in terms of their suitability to be part of a TEVG with a high potential for later clinical use.
Conventional synthetic vascular grafts require ongoing anticoagulation, and autologous venous grafts are often not available in elderly patients. This review highlights the development of bioartificial vessels replacing brain‐dead donor‐ or animal‐deriving vessels with ongoing immune reactivity. The vision for such bio‐hybrids exists in a combination of biodegradable scaffolds and seeding with immune‐neutral cells, and here different cells sources such as autologous progenitor cells or stem cells are relevant. This kind of in situ tissue engineering depends on a suitable bioreactor system with elaborate monitoring systems, three‐dimensional (3D) visualization and a potential of cell conditioning into the direction of the targeted vascular cell phenotype. Necessary bioreactor tools for dynamic and pulsatile cultivation are described. In addition, a concept for design of vasa vasorum is outlined, that is needed for sustainable nutrition of the wall structure in large caliber vessels. For scaffold design and cell adhesion additives, different materials and technologies are discussed. 3D printing is introduced as a relatively new field with promising prospects, for example, to create complex geometries or micro‐structured surfaces for optimal cell adhesion and ingrowth in a standardized and custom designed procedure. Summarizing, a bio‐hybrid vascular prosthesis from a controlled biotechnological process is thus coming more and more into view. It has the potential to withstand strict approval requirements applied for advanced therapy medicinal products.