Janin Reifenrath

Dr. Janin Reifenrath

Orthopaedic Department in Lower Saxony Centre for Biomedical Technology, Implant Research and Development, Hannover Medical School, Stadtfelddamm 34, D 30625 Hannover, Germany
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2020 in Journal of Nanobiotechnology
Verified
Journal Article
Open access
PDF file
HJHilke Catherina Janßen
Hilke Catherina Janßen
NANina Angrisani
Nina Angrisani
Stefan Michael Klaus KaliesStefan Michael Klaus Kalies
Stefan Michael Klaus Kalies
FHFlorian Hansmann
Florian Hansmann
MKManfred Kietzmann
Manfred Kietzmann
JRJanin Reifenrath
Janin Reifenrath
Background: In orthopedics, the treatment of implant-associated infections represents a high challenge. Especially, potent antibacterial effects at implant surfaces can only be achieved by the use of high doses of antibiotics, and still often fail. Drug-loaded magnetic nanoparticles are very promising for local selective therapy, enabling lower systemic antibiotic doses and reducing adverse side effects. The idea of the following study was the local accumulation of such nanoparticles by an externally applied magnetic field combined with a magnetizable implant. The examination of the biodistribution of the nanoparticles, their effective accumulation at the implant and possible adverse side effects were the focus. In a BALB/c mouse model (n = 50) ferritic steel 1.4521 and Ti90Al6V4 (control) implants were inserted subcutaneously at the hindlimbs. Afterwards, magnetic nanoporous silica nanoparticles (MNPSNPs), modified with rhodamine B isothiocyanate and polyethylene glycol-silane (PEG), were administered intravenously. Directly/1/7/21/42 day(s) after subsequent application of a magnetic field gradient produced by an electromagnet, the nanoparticle biodistribution was evaluated by smear samples, histology and multiphoton microscopy of organs. Additionally, a pathohistological examination was performed. Accumulation on and around implants was evaluated by droplet samples and histology. Results: Clinical and histological examinations showed no MNPSNP-associated changes in mice at all investigated time points. Although PEGylated, MNPSNPs were mainly trapped in lung, liver, and spleen. Over time, they showed two distributional patterns: early significant drops in blood, lung, and kidney and slow decreases in liver and spleen. The accumulation of MNPSNPs on the magnetizable implant and in its area was very low with no significant differences towards the control. Conclusion: Despite massive nanoparticle capture by the mononuclear phagocyte system, no significant pathomorphological alterations were found in affected organs. This shows good biocompatibility of MNPSNPs after intravenous administration. The organ uptake led to insufficient availability of MNPSNPs in the implant region. For that reason, among others, the nanoparticles did not achieve targeted accumulation in the desired way, manifesting future research need. However, with different conditions and dimensions in humans and further modifications of the nanoparticles, this principle should enable reaching magnetizable implant surfaces at any time in any body region for a therapeutic reason.

Verified
Journal Article
Open access
PDF file
JRJanin Reifenrath
Janin Reifenrath
MWMathias Wellmann
Mathias Wellmann
MKMerle Kempfert
Merle Kempfert
NANina Angrisani
Nina Angrisani
Bastian WelkeBastian Welke
Bastian Welke
EWElmar Willbold
Elmar Willbold
Biological factors such as TGF–β3 are possible supporters of the healing process in chronic rotator cuff tears. In the present study, electrospun chitosan coated polycaprolacton (CS–g–PCL) fibre scaffolds were loaded with TGF–β3 and their effect on tendon healing was compared biomechanically and histologically to unloaded fibre scaffolds in a chronic tendon defect rat model. The biomechanical analysis revealed that tendon–bone constructs with unloaded scaffolds had significantly lower values for maximum force compared to native tendons. Tendon-bone constructs with TGF–β3-loaded fibre scaffolds showed only slightly lower values. In histological evaluation minor differences could be observed. Both groups showed advanced fibre scaffold degradation driven partly by foreign body giant cell accumulation and high cellular numbers in the reconstructed area. Normal levels of neutrophils indicate that present mast cells mediated rather phagocytosis than inflammation. Fibrosis as sign of foreign body encapsulation and scar formation was only minorly present. In conclusion, TGF–β3-loading of electrospun PCL fibre scaffolds resulted in more robust constructs without causing significant advantages on a cellular level. A deeper investigation with special focus on macrophages and foreign body giant cells interactions is one of the major foci in further investigations.

23 September 2022 in Journal of Functional Biomaterials
Verified
Journal Article
Open access
PDF file
MKMerle Kempfert
Merle Kempfert
EWElmar Willbold
Elmar Willbold
SLSebastian Loewner
Sebastian Loewner
CBCornelia Anneliese Blume
Cornelia Anneliese Blume
JPJohannes Pitts
Johannes Pitts
JRJanin Reifenrath
Janin Reifenrath
Chronic tendon ruptures are common disorders in orthopedics. The conventional surgical methods used to treat them often require the support of implants. Due to the non-availability of suitable materials, 3D-printed polycaprolactone (PCL) scaffolds were designed from two different starting materials as suitable candidates for tendon-implant applications. For the characterization, mechanical testing was performed. To increase their biocompatibility, the PCL-scaffolds were plasma-treated and coated with fibronectin and collagen I. Cytocompatibility testing was performed using L929 mouse fibroblasts and human-bone-marrow-derived mesenchymal stem cells. The mechanical testing showed that the design adaptions enhanced the mechanical stability. Cell attachment was increased in the plasma-treated specimens compared to the control specimens, although not significantly, in the viability tests. Coating with fibronectin significantly increased the cellular viability compared to the untreated controls. Collagen I treatment showed an increasing trend. The desired cell alignment and spread between the pores of the construct was most prominent on the collagen-I-coated specimens. In conclusion, 3D-printed scaffolds are possible candidates for the development of tendon implants. Enhanced cytocompatibility was achieved through surface modifications. Although adaptions in mechanical strength still require alterations in order to be applied to human-tendon ruptures, we are optimistic that a suitable implant can be designed.

27 November 2018 in Journal of Nanobiotechnology
Verified
Journal Article
Open access
PDF file
HJHilke Catherina Janßen
Hilke Catherina Janßen
DWDawid Peter Warwas
Dawid Peter Warwas
DDDavid Dahlhaus
David Dahlhaus
JMJessica Meißner
Jessica Meißner
PTPiriya Taptimthong
Piriya Taptimthong
NANina Angrisani
Nina Angrisani
In orthopedic surgery, implant-associated infections are still a major problem. For the improvement of the selective therapy in the infection area, magnetic nanoparticles as drug carriers are promising when used in combination with magnetizable implants and an externally applied magnetic field. These implants principally increase the strength of the magnetic field resulting in an enhanced accumulation of the drug loaded particles in the target area and therewith a reduction of the needed amount and the risk of undesirable side effects. In the present study magnetic nanoporous silica core–shell nanoparticles, modified with fluorophores (fluorescein isothiocyanate/FITC or rhodamine B isothiocyanate/RITC) and poly(ethylene glycol) (PEG), were used in combination with metallic plates of different magnetic properties and with a magnetic field. In vitro and in vivo experiments were performed to investigate particle accumulation and retention and their biocompatibility. Spherical magnetic silica core–shell nanoparticles with reproducible superparamagnetic behavior and high porosity were synthesized. Based on in vitro proliferation and viability tests the modification with organic fluorophores and PEG led to highly biocompatible fluorescent particles, and good dispersibility. In a circular tube system martensitic steel 1.4112 showed superior accumulation and retention of the magnetic particles in comparison to ferritic steel 1.4521 and a Ti90Al6V4 control. In vivo tests in a mouse model where the nanoparticles were injected subcutaneously showed the good biocompatibility of the magnetic silica nanoparticles and their accumulation on the surface of a metallic plate, which had been implanted before, and in the surrounding tissue. With their superparamagnetic properties and their high porosity, multifunctional magnetic nanoporous silica nanoparticles are ideal candidates as drug carriers. In combination with their good biocompatibility in vitro, they have ideal properties for an implant directed magnetic drug targeting. Missing adverse clinical and histological effects proved the good biocompatibility in vivo. Accumulation and retention of the nanoparticles could be influenced by the magnetic properties of the implanted plates; a remanent martensitic steel plate significantly improved both values in vitro. Therefore, the use of magnetizable implant materials in combination with the magnetic nanoparticles has promising potential for the selective treatment of implant-associated infections.

1 April 2020 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
MSM.-L. Schröder
M.-L. Schröder
NAN. Angrisani
N. Angrisani
EFE. Fadeeva
E. Fadeeva
JHJ. Hegermann
J. Hegermann
JRJanin Reifenrath
Janin Reifenrath

13 April 2017 in BMC Nephrology
Verified
Journal Article
Open access
PDF file
RHRuth G. G. Hiller
Ruth G. G. Hiller
MPMargret Patecki
Margret Patecki
Claudia NeunaberClaudia Neunaber
Claudia Neunaber
JRJanin Reifenrath
Janin Reifenrath
JKJan T. Kielstein
Jan T. Kielstein
HKHeike Kielstein
Heike Kielstein
Patients with an impaired renal function show a high incidence of bone and mineral disturbances. These ‘chronic kidney disease – mineral and bone disorders’ (CKD-MBD) range from high turnover osteoporosis to adynamic bone disease. Currently, the histomorphometric analysis of a bone biopsy taken from the iliac crest is viewed as the gold standard for CKD-MBD subtype differentiation. However, the clinical relevance of such a biopsy is questionable since iliac crest fractures are an extremely rare finding. Therefore, we aimed to elucidate if the histomorphometric parameter ‘trabecular bone volume (BV/TV)’ from the iliac crest is representative for other biopsy locations. We chose two skeletal sites of higher fracture risk for testing, namely, the tibial bone and the lumbar spine, to examine if the current gold standard of bone biopsy is indeed golden. Bone biopsies were taken from 12 embalmed body donors at the iliac crest, the proximal tibia, and the lumbar vertebral body, respectively. Masson-Goldner stained sections of methyl methacrylate embedded biopsies were used for trabecular bone volume calculation. Furthermore, exemplary μ-computed tomography (XtremeCT) scans with subsequent analysis were performed. Median values of trabecular bone volume were comparable between all body donors with median (interquartile range, IQR) 18.3% (10.9–22.9%) at the iliac crest, 21.5% (9.5–40.1%) at the proximal tibia, and 16.3% (11.4–25.0%) at the lumbar spine. However, single values showed extensive intra-individual variation, which were also confirmed by XtremeCT imaging. Distinct intra-individual heterogeneity of trabecular bone volume elucidate why a bone biopsy from one site does not necessarily predict patient relevant endpoints like hip or spine fractures. Physicians interpreting bone biopsy results should know this limitation of the current gold standard for CKD-MBD diagnostic, especially, when systemic therapeutic decisions should be based on it.