This study proposes a low-cost, portable, eight-channel electrical impedance tomograph based on the AD5933 impedance converter. The patterns for current injection and voltage measurement are managed by an Arduino Mega 2560 board and four 74HC4067 Texas Instruments multiplexers. Regarding the experimental results, the errors in the impedance estimates of an electrical circuit that represents a Cole model were less than 1.14% for the magnitude and 4.15% for the phase. Furthermore, the signal-to-noise ratio measured in a resistive phantom was 55.23 dB. Additional experiments consisted of placing five spheres of different size and conductivity in a saline tank, measuring their impedance through eight electrodes, and then generating impedance maps using the Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software (EIDORS). These maps were different for each sphere, suggesting the proposed prototype as a promising alternative for medical applications.
4 May 2020 in Biomedical Physics & Engineering Express
Bioimpedance measurements are currently used to monitor various biological processes and are potentially useful for studies of urodynamics. Global impedance (GI) and focused impedance measurements (FIM) can be used to monitor bladder volumes, but these are subject to varying conductivity of urine. To address this, we emulated a human bladder using an agar phantom filled with saline solutions of varying conductivities and estimated volumes using a modified FIM-based approach. Using this novel strategy, electrical potentials did not change significantly with constantliquid volumes, even when the conductivity of the saline solutions was varied between 1.027 to 1.877 and 2.610 S/m. Conversely, GI and classic FIM measurements of constant liquid volumes varied with conductivity. These observations suggest that the proposed FIM approach is suitable for bladder volume estimation due to its robustness against uncertainties of conductivity. The bioimpedance hardware used in our experiments comprised 8 electrodes and a a small and low cost impedance measurement system based on an AFE4300 direct impedance measurement device.
A proposed low-cost, portable, 32-channel (4 rings of 8-channel) Electrical Impedance Tomography (EIT) system based on the AFE4300 analog front-end for body composition measurement. Each ring allows obtaining the conductivity distribution of 4 cross sections, 4 cm apart; to analyze the behavior of conductivity in a volume. The switching of the 4 rings and the current injection and voltage measurement patterns are done with three Texas Instruments 74HC4067 multiplexers, which are managed by an ESP32 board. The proposed system has an average signal-to-noise ratio of 74.71 dB and a frame rate of 50 fps. The sensitivity tests to impedance and volume changes consisted of introducing 4 tubes of different diameters (2 steel and 2 polyvinyl chloride) into a tank with saline solution; then conductivity distribution images were generated in 4 cross-sections of the tank, using the algorithms Gauss-Newton and Noser. Finally, the global impedance index (GI) is calculated to estimate the volume of each tube inside the tank. The results show that the proposed system is highly sensitive to impedance and volume changes, being a promising system for monitoring tissues, and fluids biological.
10 May 2024 in Biomedical Physics & Engineering Express
This study proposes a multiclass model to classify the severity of knee osteoarthritis (KOA) using bioimpedance measurements. The experimental setup considered three types of measurements using eight electrodes: global impedance with adjacent pattern, global impedance with opposite pattern, and direct impedance measurement, which were taken using an electronic device proposed by authors and based on the Analog Devices AD5933 impedance converter. The study comprised 37 participants, 25 with healthy knees and 13 with three different degrees of KOA. All participants performed 20 repetitions of each of the following five tasks: (i) sitting with the knee bent, (ii) sitting with the knee extended, (iii) sitting and performing successive extensions and flexions of the knee, (iv) standing, and (v) walking. Data from the 15 experimental setups (3 types of measurements×5 exercises) were used to train a multiclass random forest. The training and validation cycle was repeated 100 times using random undersampling. At each of the 100 cycles, 80% of the data were used for training and the rest for testing. The results showed that the proposed approach achieved average sensitivities and specificities of 100% for the four KOA severity grades in the extension, cyclic, and gait tasks. This suggests that the proposed method can serve as a screening tool to determine which individuals should undergo x-rays or magnetic resonance imaging for further evaluation of KOA.
Uno de los principales problemas en el control por modelo de referencia es que las dinámicas no modeladas, la incertidumbre paramétrica y el acoplamiento dinámico, afectan el desempeño del sistema de control. Este artículo presenta una estrategia de control bajo el enfoque back-stepping, con el fin de garantizar en primera instancia la estabilidad en lazo cerrado del sistema de control de un manipulador Scaracara de 4º de libertad, y en segunda instancia generar un sistema que sea robusto ante incertidumbres paramétricas, sin presentar grandes esfuerzos de control.
This study proposes an electrical impedance tomography (EIT) device based on a programmable system on a chip (PSoc). The EIT-PSoC system is implemented using two PSoC 5LP platforms. A resistive phantom is used to study frame frequency (fps), accuracy (Ac), and signal-to-noise ratio (SNR). A saline phantom, along with both conductive and non-conductive objects, is employed to evaluate the system’s ability to detect changes in impedance distribution. Finally, the dielectric characteristics of the human lower pelvis is emulated using four agar phantoms, allowing an evaluation of the EIT-PSoC system’s performance in response to changes in fluid volume and conductivity. Experiments conducted on the resistive phantom to characterize the EIT-PSoC system demonstrate a frame frequency of 100 fps, a median SNR of 63.59 dB, and an accuracy of 95.39% when using a 0.98 mA sinusoidal current signal at 50 kHz. EIT image reconstruction shows that the proposed system can distinguish impedance changes in the saline phantom. Additionally, by utilizing the global impedance (GI) index and the agar phantoms, the EIT-PSoC system can detect changes in volume and conductivity, making this system a promising alternative for monitoring the volume and conductivity of biological fluids.