Delineation of glioma extent for surgical or radiotherapy planning is routinely based on MRI. There is increasing awareness that contrast enhancement on T1-weighted images (T1-CE) may not reflect the entire extent of disease. The amino acid tracer 18F-DOPA (3,4-dihydroxy-6-[18F] fluoro-l-phenylalanine) has a high tumor-to-background signal and high sensitivity for glioma imaging. This study compares 18F-DOPA PET against conventional MRI for neurosurgical biopsy targeting, resection planning, and radiotherapy target volume delineation. Conventional MR and 18F-DOPA PET/CT images were acquired in 10 patients with suspected malignant brain tumors. One to 3 biopsy locations per patient were chosen in regions of concordant and discordant 18F-DOPA uptake and MR contrast enhancement. Histopathology was reviewed on 23 biopsies. 18F-DOPA PET was quantified using standardized uptake values (SUV) and tumor-to-normal hemispheric tissue (T/N) ratios. Pathologic review confirmed glioma in 22 of 23 biopsy specimens. Thirteen of 16 high-grade biopsy specimens were obtained from regions of elevated 18F-DOPA uptake, while T1-CE was present in only 6 of those 16 samples. Optimal 18F-DOPA PET thresholds corresponding to high-grade disease based on histopathology were calculated as T/N > 2.0. In every patient, 18F-DOPA uptake regions with T/N > 2.0 extended beyond T1-CE up to a maximum of 3.5 cm. SUV was found to correlate with grade and cellularity. 18F-DOPA PET SUVmax may more accurately identify regions of higher-grade/higher-density disease in patients with astrocytomas and will have utility in guiding stereotactic biopsy selection. Using SUV-based thresholds to define high-grade portions of disease may be valuable in delineating radiotherapy boost volumes.
Purpose: Outcomes for resistant metastatic castration-resistant prostate cancer (CRPC) are poor. Stereotactic ablative radiotherapy (SABR) induces antitumor immunity in clinical and preclinical studies, but immunologic biomarkers are lacking. Patients and Methods: Eighty-nine patients with oligometastatic CRPC were identified by 11C-Choline-PET (Choline-PET) from August 2016 to December 2019 and treated with SABR. Prespecified coprimary endpoints were 2-year overall survival (OS) and PSA progression. Secondary endpoints included 2-year SABR-treated local failure and 6-month adverse events. Correlative studies included peripheral blood T-cell subpopulations before and after SABR. Results: 128 lesions in 89 patients were included in this analysis. Median OS was 29.3 months, and 1- and 2-year OS were 96% and 80%, respectively. PSA PFS was 40% at 1 year and 21% at 2 years. Local PFS was 84.4% and 75.3% at 1 and 2 years, respectively, and no grade ≥3 AEs were observed. Baseline high levels of tumor-reactive T cells (TTR; CD8+CD11ahigh) predicted superior local, PSA, and distant PFS. Baseline high levels of effector memory T cells (TEM; CCR7−CD45RA−) were associated with improved PSA PFS. An increase in TTR at day 14 from baseline was associated with superior OS. Conclusions: This is the first comprehensive effector T-cell immunophenotype analysis in a phase II trial before and after SABR in CRPC. Results are favorable and support the incorporation of immune-based markers in the design of future randomized trials in patients with oligometastatic CRPC treated with SABR.
1 September 2008 in Journal of Applied Clinical Medical Physics
The accuracy of four‐dimensional computed tomography (4DCT) imaging depends on temporal characteristics of the acquisition protocol—for example, the temporal spacing of the reconstructed images (also known as cine duration between images) and the gantry rotation speed. These parameters affect the temporal resolution of 4DCT images, and a single default acquisition protocol, as commonly used in most clinics, may be suboptimal for a subset of respiratory motion characteristics. It could lead to substantial inaccuracies in target delineation. The aim of the present study was to evaluate the interplay between parameters affecting temporal resolution and the accuracy of the resulting images.We acquired 4DCT images of cylindrical phantoms under repetitive motion induced by a translation platform. Acquisition settings varied with respect to temporal spacing, gantry rotation speed, and motion period of the phantoms. Reconstructed images were sorted into 10 phase bins and were compared to static phantom images acquired at corresponding positions of the respiration phase. Acquisitions with different temporal spacing did not play a significant role in the amount of motion observed in full‐cycle maximum intensity projection images. Target delineation accuracy at end‐of‐inhalation phase was observed to be constant up to a threshold in the value of the reconstruction interval, beyond which it varied arbitrarily. This threshold was found to be correlated with the number of phase bins and the motion period. No observable variations were noted with images from the end of exhalation when temporal spacing was varied. Target delineation accuracy was observed to be enhanced in acquisitions using faster gantry rotation speeds. An evaluation of the acquisition parameters needs to be performed depending on the period of the motion and limiting factors such as the availability of acquisition settings, X‐ray tube workload, image storage, and processing power.PACS numbers: 87.53.Xd, 87.57.‐s, 87.57.Gg, 87.59.Fm
Purpose: To evaluate the performance of a new, highly flexible radiofrequency (RF) coil system for imaging patients undergoing MR simulation. Methods: Volumetric phantom and in vivo images were acquired with a commercially available and prototype RF coil set. Phantom evaluation was performed using a silicone-filled humanoid phantom of the head and shoulders. In vivo assessment was performed in five healthy and six patient subjects. Phantom data included T1-weighted volumetric imaging, while in vivo acquisitions included both T1- and T2-weighted volumetric imaging. Signal to noise ratio (SNR) and uniformity metrics were calculated in the phantom data, while SNR values were calculated in vivo. Statistical significance was tested by means of a non-parametric analysis of variance test. Results: At a threshold of p = 0.05, differences in measured SNR distributions within the entire phantom volume were statistically different in two of the three paired coil set comparisons. Differences in per slice average SNR between the two coil sets were all statistically significant, as well as differences in per slice image uniformity. For patients, SNRs within the entire imaging volume were statistically significantly different in four of the nine comparisons and seven of the nine comparisons performed on the per slice average SNR values. For healthy subjects, SNRs within the entire imaging volume were statistically significantly different in seven of the nine comparisons and eight of the nine comparisons when per slice average SNR was tested. Conclusions: Phantom and in vivo results demonstrate that image quality obtained from the novel flexible RF coil set was similar or improved over the conventional coil system. The results also demonstrate that image quality is impacted by the specific coil configurations used for imaging and should be matched appropriately to the anatomic site imaged to ensure optimal and reproducible image quality.