The concept of Statistical process control (SPC) was given by the physicist Walter Shewhart in order to improve the industrial manufacturing. The SPC was firstly applied in laboratory and after then shifted to patient level in hospitals. As there is more involvement of human in healthcare, the chances of errors are also more. SPC i.e., control chart can help in determining the source of errors by identifying the special and common causes of variations. This paper presents the review of literature on the application of SPC and control chart in healthcare sector. Forty articles are selected out of 142 potentially relevant searched studies. Selected studies are categorised into eight departments. Literature survey shows that most of work on control chart applications in healthcare is carried out in Surgery, Emergency and Epidemiology departments. US, UK and Australia are the main customers where maximum amount of work was done. The US is the country where control chart in healthcare sector have been used at regular interval. This shows the gap of deploying control chart in different departments and different countries as well. The CUSUM and EWMA chart came into picture in healthcare sector after 2008 and are used at regular interval.
Purpose: The purpose of this paper is to investigate the utilization of Lean & Six Sigma quality initiatives in healthcare sector in India. Methodology: The survey questionnaires were sent to 454 hospitals through registered postal in all the states of India. The survey questionnaire was designed to assess different quality initiatives; currently implemented in Indian hospitals, factors align with organization’s objectives, reasons for not implementing Lean & Six Sigma and contribution of Lean & Six Sigma projects in healthcare improvement projects etc. A separate section in the questionnaire provides the feedback on implementation of Lean & Six Sigma in various hospitals. The relationships between Lean & Six Sigma and healthcare performance have also been established in this paper. Findings: It is found that 15 Nos. of hospitals have implemented the Lean tools while 14 Nos. have implemented the Six Sigma tools out of 109 collected responses. This shows the utilization of Lean & Six Sigma in Indian healthcare sector. The ‘Lack of knowledge’ and ‘Availability of resources’ are the major reasons for not implementing Lean & Six Sigma. It is also observed that 22% running projects were related to Lean & Six Sigma out of various improvement projects running in various hospitals. Originality: There is lack of evidences of similar studies that determines the utilization of Lean & Six Sigma in Indian healthcare sector at the national level. This paper will provide important breakthrough to academicians and healthcare practitioners, who are involved in Lean & Six Sigma research. Social implications: The present study will create awareness among healthcare practitioners across India for utilization of quality tools that will provide direct benefits to the society.
The current examination used a multi-criteria decision-making (MCDM) approach to optimize the roughness parameters of S-shaped ribs (SSRs) in a solar thermal collector (STC) duct using air as the working fluid. Different SSRs were tested to identify the combination of parameters resulting in the best performance. Geometrical parameters such as relative roughness pitch () varied from 4 to 12, relative roughness height () from 0.022 to 0.054, arc angle () from 30° to 75°, and relative roughness width () from 1 to 4. The Nusselt number () and friction factor (), findings which impact the STC performance, rely on SSRs. The performance measurements show that no combination of SSR parameters lead to the best enhancement heat transfer rate at low enhancement in the friction. So, a hybrid multi-criteria decision-making strategy using the Analytical Hierarchy Process (AHP) for criterion significance and Multi Attributive Border Approximation Area Comparison (MABAC) for alternative ranking was used to determine which combination of geometrical parameters will result in the optimum performance of a roughened STC. This work employs a hybrid MCDM technique to optimise the effectiveness of an STC roughened with SSRs. To optimize the SSR design parameters, this study used the hybrid AHP-MABAC technique for analytical assessment of a roughened STC. The optimization results showed that the STC roughened with SSRs achieved the optimum performance at = 8, = 0.043, = 60° and = 3.
1 April 2015 in International Journal of Modeling and Optimization
This paper presents the economic design of modified X̅ chart for autocorrelated data and comparison with the economic design of Shewhart’s X̅ chart. An attempt has been made to counter autocorrelation by designing the modified X̅ chart; as the cost of operating a process control system is an important element in the economic design of control charts. The economic designs of both modified and Shewhart X̅ charts for autocorrelated observations are presented; using Lorenzen-Vance [1] cost model. The modified X̅ chart is based upon sum of chi-squares and has simplicity like Shewhart X̅ chart but more efficient than standard chart. Two sets of parameters suggested by Montgomery [2] are used to determine the optimal sampling intervals (h) and expected costs per hour. It shows that sampling interval (h) and expected cost/hour (C) depend upon various parameters of chart, used in this model. The expected costs/hour (C) for both the charts are computed for sample sizes of 2 and 4 at the various levels of correlation and process shifts in mean. It is concluded that at each level of correlation and shift in the process mean, the expected costs/hour of the modified X̅ chart are lower than the Shewhart chart.