Building-integrated photovoltaics (BIPV) requires tools that improve and facilitate simulating and predicting the system’s output energy. The efficiency of a photovoltaic (PV) system can be determined by the performance ratio (PR), which relates the actual system’s output energy to the theoretical output according to the installed power and the solar irradiation, thus accounting for the power losses the PV system undergoes. Among the different parameters affecting PR, module temperature and the angle of incidence of irradiance are the most dependent on the BIPV application due to the varied module positioning. This paper assesses the suitability of several BIPV temperature models and determines the angular losses for any possible module positioning. The proposed methodology is easy to replicate and results in polar heatmap graphs to estimate PR at the desired location as a function of the tilt and azimuth angles of the modules. The calculations require irradiance, ambient temperature, and wind speed data, which can easily be obtained worldwide. Dynamic sky conditions are addressed through filters that smooth out quickly changing input data to avoid high and low peaks. The developed graphs are helpful in the decision-making process for BIPV designs by allowing the designer to estimate the expected PR of the BIPV system for any possible position of the modules on the building envelope, reducing the effect of uncertainties and resulting in more accurate and better predictions of the system’s output energy. The method applied to a BIPV façade in Madrid showed a deviation of less than 3% between the estimated and monitored PRs; the PR values ranged between 0.74 and 0.82, depending on the BIPV application and module position.
This paper provides a methodology for improving the modelling and design of BIPV façades through in-depth solar irradiation calculations using free and open-source software, mainly GIS, in addition to free data, such as LiDAR, cadastres and meteorological databases. The objective is to help BIPV design with a universal and easy-to-replicate procedure. The methodology is validated with the case study of Building 42 in the CIEMAT campus in Madrid, which was renovated in 2017 to integrate photovoltaic arrays in the east, south and west façades, with monitoring data of the main electrical and meteorological conditions. The main novelty is the development of a methodology where LiDAR data are combined with building vector information to create an enhanced high-definition DSM, which is used to develop precise yearly, monthly and daily façade irradiation estimations. The simulation takes into account terrain elevation and surrounding buildings and can optionally include existing vegetation. Gridded heatmap layouts for each façade area are provided at a spatial resolution of 1 metre, which can translate to PV potential. This methodology can contribute to the decision-making process for the implementation of BIPV in building façades by aiding in the selection of the areas that are more suitable for PV generation.
This chapter summarises the content and intention of the book. It introduces the Building-Integrated Photovoltaic (BIPV) technology and the definition of BIPV modules and explains the scope of this book. Then, it gives a summary of each chapter. <!----> <!----> <!----> <!---->
Chapter 5 addresses the practical technical details for developing constructive BIPV solutions. Technical notes and drawings for different types of roofs, façades, and external devices are meant to guide architects and engineers in the design process of BIPV systems. A selection of 24 outstanding BIPV case studies, with detailed technical descriptions, pictures, and technical drawings is intended to be a motivation source for developing successful BIPV projects. <!----> <!----> <!----> <!---->
Building-integrated photovoltaics (BIPVs) offer significant potential for energy-efficient building renovations by seamlessly integrating renewable energy generation into the built environment. This work highlights the strategic opportunity for BIPV within the current European and international context, where the building stock faces an increasingly urgent need for large-scale rehabilitation. BIPV solutions and products for building retrofit are reviewed holistically considering thermal insulation, solar control, daylighting, architectural design, aesthetics, and electrical performance to optimise energy savings and increase social acceptance. A selection of nine international case studies illustrates the versatility of BIPV across diverse building typologies, including projects focused on heritage preservation for which targeted measures are proposed. Despite the opportunities, BIPV adoption remains limited, primarily due to regulatory, economic, and socio-cultural barriers. The specific challenges of BIPV retrofitting in heritage and protected buildings are also examined. Multiple studies have demonstrated BIPV cost-effectiveness, especially when fiscal incentives, environmental co-benefits, and architectural factors are considered. Nonetheless, affordability remains a barrier for many households, highlighting the need for comprehensive financial support to accelerate market uptake. This review is intended to provide a broad audience—including researchers, architects, building professionals, and decision-makers—with a comprehensive, structured overview of BIPV renovation opportunities.