Amneh Z. Alshawabka

Dr. Amneh Z. Alshawabka

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HAHuthaifa Atallah
Huthaifa Atallah
AAAmneh Z. Alshawabka
Amneh Z. Alshawabka
MAMahmoud Alfatafta
Mahmoud Alfatafta
TATariq Zeyad Mohammad Alkhatib
Tariq Zeyad Mohammad Alkhatib
MTMarwan Taher
Marwan Taher
BMBalint Molics
Balint Molics
Background: Lower limb amputation affects physical function, mental health, and body image. Rehabilitation outcomes depend on both psychological adjustment and functional performance, including mobility and prosthesis satisfaction. This study aimed to evaluate psychological adjustment, activity restriction, and prosthesis satisfaction among lower-limb prosthetic users in Jordan using the Arabic TAPES-R. Objective: To assess, using a validated tool, the psychological adjustment, activity restriction, and prosthesis satisfaction of lower-limb prosthetic users in Jordan, aligning with the study title and cross-sectional design. Methods: This cross-sectional study included 74 unilateral lower-limb prosthetic users (66.2% male, mean age 42.4 ± 13.1 years). Sociodemographic and body composition characteristics were recorded. Participants completed the Arabic TAPES-R between September 2024 and April 2025. The TAPES-R measured psychosocial adjustment, activity restriction, and prosthesis satisfaction. Data were analyzed using descriptive statistics, Cronbach’s alpha for internal consistency, independent-samples t-tests, and Pearson correlations (p < 0.05). Results: Participants demonstrated generally positive psychosocial adjustment (Psychosocial Total = 3.08 ± 0.52) and moderate prosthesis satisfaction (Total Satisfaction = 2.23 ± 0.47), with variable activity restriction (8.76 ± 5.61). Internal consistency was strong across TAPES-R subscales (α = 0.816–0.955). Functional Satisfaction was higher in those with transfemoral than transtibial amputation (p = 0.041). Psychosocial adjustment correlated positively with prosthesis satisfaction (r = 0.48, p < 0.001) and negatively with activity restriction (r = −0.52, p < 0.001). Residual limb pain (45.9%) was associated with higher activity restriction (p = 0.022), and phantom limb pain (55.4%) with lower prosthetic satisfaction (p = 0.031). Conclusions: The Arabic TAPES-R effectively identifies psychological adjustment, activity restriction, and prosthesis satisfaction in lower-limb prosthetic users in Jordan. Participants generally reported positive psychosocial adjustment and moderate prosthesis satisfaction, but functional limitations remain, particularly in those with residual or phantom limb pain. These findings support the use of the TAPES-R as a clinical and research screening tool and provide guidance for targeted rehabilitation interventions.

22 October 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
AAAmneh Z. Alshawabka
Amneh Z. Alshawabka
MAMahmoud Alfatafta
Mahmoud Alfatafta
HAHuthaifa Atallah
Huthaifa Atallah
FAFahad Alhazmi
Fahad Alhazmi
MAMohannad Alkhateeb
Mohannad Alkhateeb
WQWa'el Nafith Abdel-Fattah Qa'dan
Wa'el Nafith Abdel-Fattah Qa'dan
Background/Objectives: The Chippaux–Smirak Index (CSI) measures relative midfoot plantar contact, whereas the six-item Foot Posture Index (FPI-6), navicular drop test (NDT), and resting calcaneal stance position (RCSP) assess static foot posture, change in navicular height, and calcaneal alignment, respectively. This study examined associations among these measures, agreement between CSI and FPI-6 classifications, and measurement reliability in young adults. Methods: This cross-sectional study included 350 young adults, with both feet assessed (700 feet). Two orthotists independently measured CSI, FPI-6, NDT, and RCSP. Generalised estimating equation models accounted for correlations between feet and were adjusted for age, sex, body mass index, and foot side. Agreement was assessed using exact percentage agreement and linear weighted Cohen’s kappa, and reliability using intraclass correlation coefficients (ICCs). Results: After adjustment, each increase of 10 percentage points in CSI was associated with a 2.141-point-higher FPI-6 total score, a 2.660 mm greater navicular drop, and an RCSP that was 3.240° more valgus (all p < 0.001). CSI and grouped FPI-6 classifications agreed for 82.9% of feet (linear weighted κ = 0.664, 95% CI 0.595–0.727). Single-measure interrater ICCs ranged from 0.644 for NDT to 0.884 for CSI. Digital remeasurement of CSI demonstrated excellent intrarater reliability (ICC(A,1) = 0.989). Conclusions: Higher CSI values were associated with a more pronated static foot posture, greater navicular drop, and a more valgus RCSP. Incomplete agreement between CSI and FPI-6 classifications indicates that these methods provide related but distinct information and should be interpreted according to the specific foot characteristic assessed.

Verified
Journal Article
Open access
PDF file
AAAmneh Z. Alshawabka
Amneh Z. Alshawabka
WQWa'el Nafith Abdel-Fattah Qa'dan
Wa'el Nafith Abdel-Fattah Qa'dan
MAMahmoud Alfatafta
Mahmoud Alfatafta
HAHuthaifa Atallah
Huthaifa Atallah
AMAnthony Mcgarry
Anthony Mcgarry
BMBalint Molics
Balint Molics
Background: Ankle foot orthosis–footwear combination (AFO–FC) tuning involves structured adjustment of the AFO relative to footwear to optimise shank alignment and ground reaction force (GRF) positioning during stance. Although established biomechanical frameworks and clinical algorithms are available, variability in clinical implementation persists. Previous investigations have primarily relied on self-reported practice within single healthcare settings and have not, to our knowledge, systematically examined how orthotists articulate and apply tuning principles within structured clinical reasoning across diverse educational and practice environments. Objectives: This study aimed to determine the level of awareness and framework-based proficiency in AFO–FC tuning among practising orthotists in a geographically diverse convenience sample, to examine the extent to which AFO–FC tuning is integrated into routine clinical practice, and to explore associations between framework-based proficiency level and selected professional characteristics. Methods: A cross-sectional study was conducted using an online survey of practising orthotists (n = 245). Awareness of AFO–FC tuning and self-reported routine implementation were assessed. Framework-based proficiency was evaluated among respondents reporting awareness (n = 212) using structured content analysis of open-text responses within a predefined exploratory five-domain biomechanical framework, and classified as limited (0–1 domains), partial (2–3 domains), or full (4–5 domains). Associations between framework-based proficiency level and professional characteristics were examined using chi-square tests. Binary logistic regression was performed to assess the association between framework-based proficiency level and self-reported routine implementation. Results: Self-reported awareness of AFO–FC tuning was high (86.5%), whereas 53.5% reported routine implementation. Based on the framework scoring, 59.0% demonstrated limited framework-based proficiency, 31.6% partial framework-based proficiency, and 9.4% full framework-based proficiency. No statistically significant associations were observed in this sample between framework-based proficiency level and educational qualification, years of clinical experience, or annual AFO case volume (p > 0.05). Full framework-based proficiency was associated with higher odds of self-reported routine implementation (OR = 4.03, 95% CI 1.44–11.25, p = 0.008). Conclusions: Despite high self-reported awareness, framework-based proficiency in AFO–FC tuning was limited within this sample. Self-reported routine implementation was more frequently reported among respondents with higher framework-based proficiency, whereas no statistically significant associations were observed with educational level, clinical experience, or annual AFO case volume. These hypothesis-generating findings should be interpreted cautiously given the cross-sectional design and framework-based (non-validated) classification.

Verified
Journal Article
Open access
PDF file
HAHuthaifa Atallah
Huthaifa Atallah
TQTiteana Qufabz
Titeana Qufabz
MAMahmoud Alfatafta
Mahmoud Alfatafta
AAAmneh Z. Alshawabka
Amneh Z. Alshawabka
MYMohamad Samih Yasin
Mohamad Samih Yasin
BMBalint Molics
Balint Molics
Background/Objectives: Limb-length discrepancy (LLD) is a relatively common condition, with structural LLD characterized by true shortening of a bony structure. Although various clinical and radiological methods are available, none rely exclusively on position of malleoli relative to one another. This study aims to introduce a novel method for measuring structural LLD using malleoli in conjunction with a ruler. A quasi-experimental study. Methods: Eighteen participants with structural LLD were recruited from an orthopaedic clinic. Each participant underwent four tests: Paired Medial Malleolus Level Test (PMMLT) (new method), measuring tape method (Anterior Superior Iliac Spine (ASIS) to Medial Malleoli (MM), standing-block test, and full-length standing (long bone) radiography. Validity was assessed against radiography. Results: The mean ± SD LLD measured by radiography was 2.99 ± 1.69 cm. Corresponding values were obtained with the PMMLT (2.98 ± 1.69 cm), measuring tape method (2.95 ± 1.66 cm), and the standing-block test (2.92 ± 1.73 cm). No significant differences were found among the methods (χ2(3) = 3.43, p = 0.330). Correlations with radiography were very strong (PMMLT r = 0.996; measuring tape method r = 0.990; standing-block test r = 0.991; all p < 0.001). PMMLT showed negligible bias (−0.01 cm), the narrowest 95% limits of agreement (−0.32 to 0.30 cm), and the lowest RMSE (0.15 cm). Conclusions: The PMMLT demonstrates accuracy and practicality while being simple, cost-effective, and free of radiation exposure, making it a valuable alternative for clinical assessment of LLD in settings where imaging is unavailable or contraindicated.

9 September 2025
Verified
Book Chapter
Closed access
PDF file
PRPawan Kumar Rakesh
Pawan Kumar Rakesh
PKPravin Kumar
Pravin Kumar
ÁSÁdám Tibor Schlégl
Ádám Tibor Schlégl
Peter MarotiPeter Maroti
Peter Maroti
VCVanda Agnes Cziger-Nemes
Vanda Agnes Cziger-Nemes
LTLuca Toth
Luca Toth
The chapter discusses the integration of additive manufacturing (AM) technologies in fabricating personalized implantable prosthetics. It highlights the evolution and expansion of three-dimensional (3D) printing in medical applications, such as orthopedics, neurosurgery, dentistry, and reconstructive surgery. Various AM techniques, such as laser powder bed fusion, electron beam melting, and stereolithography, have facilitated the production of complex structures tailored to individual patient needs. Key advancements include the development of biocompatible materials like titanium and polyether ether ketone (PEEK), as well as surface modifications that enhance osseointegration. Additionally, emerging technologies such as 4D printing and smart sensors are explored for their potential in further optimizing prosthetic functionality and real-time monitoring of implants. Despite these innovations, challenges remain in terms of regulatory approval, cost reduction, and ensuring long-term clinical safety. The document stresses the importance of multidisciplinary collaboration among medical professionals, engineers, and biotechnologists to advance the field of implantable prosthetics. <!----> <!----> <!----> <!---->

5 November 2026 in BMC Medical Education
Verified
Journal Article
Open access
PDF file
HAHuthaifa Atallah
Huthaifa Atallah
RARaghad Albeetar
Raghad Albeetar
MAMahmoud Alfatafta
Mahmoud Alfatafta
AAAmneh Z. Alshawabka
Amneh Z. Alshawabka
AMAnthony Mcgarry
Anthony Mcgarry
BMBalint Molics
Balint Molics
Background: A global shortage of healthcare professionals highlights the requirement for an educated workforce in the prosthetics and orthotics (P&O) field. Critical thinking (CT) dispositions are paramount for P&O students, who deal with complex clinical scenarios while providing evidence-based care. Yet, few studies examine the career choice motivators and the development in critical thinking. Aim: To explore the incentives and barriers to candidates when selecting P&O as an undergraduate course and to evaluate the development of critical thinking (CT) dispositions of students as they progress through their undergraduate prosthetics and orthotics (P&O) degree. Study design: A cross-sectional study. Methods: A total of 252 undergraduate P&O students completed a structured survey consisting of two parts: [1] career choice decision including demographics, motivations, and perceived barriers; and [2] CT dispositions using the California Critical Thinking Disposition Inventory (CCTDI). Results: The female-to-male ratio of students was 3.6:1, with most deciding to pursue the P&O profession during secondary education. Helping others and improving patients’ quality of life were key motivators, while limited awareness of the profession was the most cited barrier. Students frequently identified independent research as a major influence in their final decision to apply for the degree. CT dispositions showed a positive tendency, with a mean total score of 329 out of 420. Significant differences in CT skill development were observed across year of study ( p = 0.001) and age ( p = 0.003). Conclusion: Findings emphasize the importance of increased early awareness of the P&O profession. A general positive tendency of development of CT dispositions was observed among P&O students, with improvement in their CT dispositions as they progressed through academic years.