Titeana Qufabz

Ms. Titeana Qufabz

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
HAHuthaifa Atallah
Huthaifa Atallah
TQTiteana Qufabz
Titeana Qufabz
RNRabee Naeem
Rabee Naeem
HBHadeel R. Bakhsh
Hadeel R. Bakhsh
GFGiorgio Ferriero
Giorgio Ferriero
BMBalint Molics
Balint Molics
Introduction: 3D-printing is an emerging technology in the field of prosthetics, offering advantages such as cost-effectiveness, ease of customization, and improved accessibility. While previous reviews have focused on limited aspects, the aim of this systematic review is to provide a comprehensive evaluation of the clinical outcomes of 3D-printed prostheses for both upper and lower limbs. Methods: A search was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines across six databases (PubMed, Web of Science, EBSCO, Scopus, Cochrane Library, and Sage). Studies on 3D-printed prostheses in human rehabilitation that focused on the clinical outcomes of the device were included, while studies lacking clinical data, 3D printing details, or focusing on traditional manufacturing methods were excluded. Finally, the risk of bias was assessed using the modified Downs & Black Checklist. Results: A total of 1420 studies were identified, with 11 meeting the inclusion criteria. The included studies assessed different 3D-printed prosthetic types and upper and lower limb prostheses. The main clinical outcomes analyzed were functional performance, design and material integrity, and overall effectiveness of 3D-printed prostheses. Studies on upper limb prostheses reported improved dexterity, range of motion (ROM), and user satisfaction, despite some durability limitations. Lower limb prostheses showed enhancements in comfort, gait parameters, and customization, particularly in amphibious and partial foot designs. Conclusions: 3D-printed prostheses show potential to improve functional performance, patient satisfaction, fit, and implementation feasibility compared to conventional methods. However, limitations such as small sample sizes, variability in assessment tools, and limited high-quality evidence highlight the need for further research to support broader clinical adoption.

Verified
Journal Article
Open access
PDF file
HAHuthaifa Atallah
Huthaifa Atallah
TQTiteana Qufabz
Titeana Qufabz
MAMahmoud Alfatafta
Mahmoud Alfatafta
AAAmneh Z. Alshawabka
Amneh Z. Alshawabka
MYMohamad Samih Yasin
Mohamad Samih Yasin
BMBalint Molics
Balint Molics
Background/Objectives: Limb-length discrepancy (LLD) is a relatively common condition, with structural LLD characterized by true shortening of a bony structure. Although various clinical and radiological methods are available, none rely exclusively on position of malleoli relative to one another. This study aims to introduce a novel method for measuring structural LLD using malleoli in conjunction with a ruler. A quasi-experimental study. Methods: Eighteen participants with structural LLD were recruited from an orthopaedic clinic. Each participant underwent four tests: Paired Medial Malleolus Level Test (PMMLT) (new method), measuring tape method (Anterior Superior Iliac Spine (ASIS) to Medial Malleoli (MM), standing-block test, and full-length standing (long bone) radiography. Validity was assessed against radiography. Results: The mean ± SD LLD measured by radiography was 2.99 ± 1.69 cm. Corresponding values were obtained with the PMMLT (2.98 ± 1.69 cm), measuring tape method (2.95 ± 1.66 cm), and the standing-block test (2.92 ± 1.73 cm). No significant differences were found among the methods (χ2(3) = 3.43, p = 0.330). Correlations with radiography were very strong (PMMLT r = 0.996; measuring tape method r = 0.990; standing-block test r = 0.991; all p < 0.001). PMMLT showed negligible bias (−0.01 cm), the narrowest 95% limits of agreement (−0.32 to 0.30 cm), and the lowest RMSE (0.15 cm). Conclusions: The PMMLT demonstrates accuracy and practicality while being simple, cost-effective, and free of radiation exposure, making it a valuable alternative for clinical assessment of LLD in settings where imaging is unavailable or contraindicated.

29 September 2026 in Healthcare
Verified
Journal Article
Open access
PDF file
HAHuthaifa Atallah
Huthaifa Atallah
TQTiteana Qufabz
Titeana Qufabz
EDEman Zmaily Dahmash
Eman Zmaily Dahmash
OTOmar M Tarawneh
Omar M Tarawneh
TNToni Nisula
Toni Nisula
BMBalint Molics
Balint Molics
Introduction: Three-dimensional (3D) printing is an emerging technology with the potential to transform prosthetics and orthotics (P&O) education and clinical practice by enabling faster, more customized, and cost-effective device production. However, its adoption of routine P&O practice remains limited, particularly in the Middle East, and little is known about practitioners’ readiness to implement this technology. Aim: To evaluate the readiness for and acceptance of integrating 3D printing into P&O practice using the Unified Theory of Acceptance and Use of Technology (UTAUT). Methodology: A descriptive cross-sectional study was conducted using a UTAUT-based questionnaire distributed through professional networks and social media. A total of 104 participants, including P&O professionals and final-year P&O students from Jordan, completed the survey. Descriptive statistics and multiple linear regression analyses were performed to identify factors influencing the behavioral intention to adopt 3D printing technology. Results: Most participants were familiar with the concept of 3D printing in P&O (62.5%), whereas only 12.5% reported that their workplace currently uses 3D printing for prosthetic or orthotic design or fabrication. Performance Expectancy (3.38 ± 0.66) and Effort Expectancy (3.40 ± 0.70) received moderately positive ratings, while Facilitating Conditions had the lowest mean score (2.58 ± 0.84), indicating limited organizational readiness. Behavioral Intention was moderate (3.02 ± 0.99). Multiple linear regression analysis showed that Performance Expectancy (β = 0.518, p < 0.001) was the strongest significant predictor of Behavioral Intention, while Facilitating Conditions (β = 0.215, p = 0.008) was also a significant predictor. The model explained 45.5% of the variance in Behavioral Intention (R2 = 0.455). The most frequently reported barriers were limited technical expertise, lack of organizational priority, and inadequate access to 3D printing equipment and materials. Participants identified training in computer-aided design (CAD) and improved access to digital manufacturing technologies as key implementation needs. Conclusions: P&O professionals and students demonstrated positive attitudes toward 3D printing and a willingness to adopt the technology; however, implementation remains constrained by inadequate infrastructure, limited technical support, insufficient training opportunities, and organizational barriers. Strengthening facilitating conditions through investment in digital infrastructure, curriculum integration, workforce training, and institutional support is likely to accelerate the adoption of 3D printing in P&O education and clinical practice.