Tatiana Svalova

Dr. Tatiana Svalova


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Biosensors
Verified
Journal Article
Open access
PDF file
AKAlisa Kozitsina
Alisa Kozitsina
TSTatiana Svalova
Tatiana Svalova
NMNatalia N. Malysheva
Natalia N. Malysheva
AOAndrei Okhokhonin
Andrei Okhokhonin
MVMarina B. Vidrevich
Marina B. Vidrevich
KBKhiena Brainina
Khiena Brainina
Analytical chemistry is now developing mainly in two areas: automation and the creation of complexes that allow, on the one hand, for simultaneously analyzing a large number of samples without the participation of an operator, and on the other, the development of portable miniature devices for personalized medicine and the monitoring of a human habitat. The sensor devices, the great majority of which are biosensors and chemical sensors, perform the role of the latter. That last line is considered in the proposed review. Attention is paid to transducers, receptors, techniques of immobilization of the receptor layer on the transducer surface, processes of signal generation and detection, and methods for increasing sensitivity and accuracy. The features of sensors based on synthetic receptors and additional components (aptamers, molecular imprinted polymers, biomimetics) are discussed. Examples of bio- and chemical sensors’ application are given. Miniaturization paths, new power supply means, and wearable and printed sensors are described. Progress in this area opens a revolutionary era in the development of methods of on-site and in-situ monitoring, that is, paving the way from the “test-tube to the smartphone”.

19 July 2016 in Analytical Letters
Verified
Journal Article
Closed access
AKA. Kozitsina
A. Kozitsina
TSTatiana Svalova
Tatiana Svalova
NMN. Malysheva
N. Malysheva
YGYu. Glazyrina
Yu. Glazyrina
AMA. Matern
A. Matern
VRV. Rusinov
V. Rusinov
A simple and inexpensive immunosensor is reported for the rapid determination of Staphylococcus aureus B-1266 that uses Fe3O4–SiO2–NH2 nanoparticles as the direct signal label. The electrochemical immunoassay procedure includes the incubation of bacteria with excess magnetite nanoparticles, the magnetic separation of the free nanoparticles, a labeled immunocomplex formation on the surface of a planar electrode, and the electrochemical response from the magnetite nanoparticles in the immunocomplex. The electrochemical immunosensor allows for the selective and accurate detection of S. aureus from 10 to 105 CFU mL−1 with a relative standard deviation lower than 10%. The limit of detection was 8.7 CFU mL−1.