Jorge Rubio Climent

Dr. Jorge Rubio Climent

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2019 in Acta Stomatologica Croatica
Verified
Journal Article
Open access
JCJorge Rubio Climent
Jorge Rubio Climent
JZJosé Ignacio Zarzosa
José Ignacio Zarzosa
APAntonio Pallarés
Antonio Pallarés
This study was designed to test the null hypothesis that there were no significant differences between size 25 files F360, F6 SkyTaper, Hyflex EDM, iRace, Neoniti, One Shape Protaper Next, Reciproc, Revo-S and Wave One Gold in terms of resistance to cyclic fatigue and length of broken fragments. 300 new size 25 files of the systems studied were selected (n=30). The instruments were mechanized with a X-Smart Plus endo motor at the speed and torque recommended by the manufacturer, holding the instruments steady with a clamping mechanism, with passive adjustment and without pressure in a stainless-steel block. The time was calculated in seconds until fracture. The number of fatigue cycles was calculated as (Resistance (s) x Speed)/60. The separated fragment lengths were measured with a digital Vernier calliper. A statistical analysis was performed with the SPSS 18 programme at a 95% confidence level, using the Levene´s Test to compare variances, the Welch's Test to compare means, and the Games-Howell´s Test to reveal differences between groups. The Levene's Test showed no equal variances (P<0.05). The Welch's Test (P<0.05) showed significant differences in cyclic fatigue and separated fragment lengths. The Games-Howell test (P<0.05) exhibited significant differences in multiple comparisons, (P<0.05). The systems with CM-Wire (Hyflex EDM and Neoniti) were superior in resistance to the other systems for cyclic fatigue. For separated fragment lengths, F360 (conventional NiTi) and Reciproc (M-Wire) were better significantly better in terms of resistance.

15 September 2017 in Acta Stomatologica Croatica
Verified
Journal Article
Open access
JCJorge Rubio Climent
Jorge Rubio Climent
JZJosé Ignacio Zarzao
José Ignacio Zarzao
APAntonio Pallarés
Antonio Pallarés
The aim of this study was to compare the cutting are, root canal anatomy preservation and non-instrumented areas of F360®, F6-SkyTaper®, Hyflex-EDM®, iRACE®, Neoniti®, O.Shape®, P.Next®, Reciproc®, Revo-S® and Wave-One-Gold® size 25 files. 300 teeth with a single straight root and a circular or elliptical root canal were divided into 10 groups (1-F360®, 2- F6-SkyTaper®, 3-Hyflex-EDM®, 4-iRACE®, 5-Neoniti®, 6-O.Shape®, 7-P.Next®, 8-Reciproc®, 9-Revo-S® and 10-Wave-One-Gold®) cut into 3 cross sections using an ultrafine cutting disc. They were photographed under a stereo microscope and preinstrumentation analyses were made before rebuilding the teeth with# 10 K- File and epoxy glue. A glide path was created with #10 and #15 K files and each group was instrumented using rotary or reciprocating systems. Cutting areas, root canal anatomy preservation and non-instrumented areas were analyzed using the AutoCAD 2015 Levene's test, the Welch´s test, and the Games-Howell´s test. The Pearson’s chi-squared test was used for statistical analysis. Levene's test showed no equality of variances (P0.05). In non-instrumented areas, significant differences were found (P<0.05) in middle third being better in Reciproc®, Neoniti® and WaveOneGold®, and in apical thirds being higher P.Next®, Reciproc®, HyflexEDM®, Neoniti® and WaveOneGold®. In cutting area, P.Next® and Reciproc® were superior in coronal third, Neoniti® and Hyflex EDM® medially and apically and Neoniti® and Reciproc® overall. Regarding the root canal anatomy preservation, all systems were similar. For non-instrumented areas, all systems achieved similar results coronally, but Reciproc®, Neoniti® and Wave One Gold® were superior in middle third and P.Next®, Reciproc®, Hyflex EDM®, Neoniti® and Wave One Gold® were superior in apically.

15 December 2015 in Acta Stomatologica Croatica
Verified
Journal Article
Closed access
JCJorge Rubio Climent
Jorge Rubio Climent
JZJosé Ignacio Zarzosa
José Ignacio Zarzosa
APAntonio Pallarés
Antonio Pallarés
This study compared the cutting area, instrumentation time, root canal anatomy preservation and non-instrumented areas obtained by F360(®), Mtwo(®), RaCe(®) and Hyflex(®) files with ISO size 35. 120 teeth with a single straight root and root canal were divided into 4 groups. Working length was calculated by using X-rays. The teeth were sectioned with a handpiece and a diamond disc, and the sections were observed with Nikon SMZ-2T stereoscopic microscope and an Intralux 4000-1 light source. The groups were adjusted with a preoperative analysis with AutoCAD. The teeth were reconstructed by a #10 K-File and epoxy glue. Each group was instrumented with one of the four file systems. The instrumentation time was calculated with a 1/100 second chronometer. The area of the thirds and root canal anatomy preservation were analyzed with AutoCAD 2013 and the non-instrumented areas with AutoCAD 2013 and SMZ-2T stereoscopic microscope. The statistical analysis was made with Levene's Test, ANOVA, Bonferroni Test and Pearson´s Chi-square. Equal variances were shown by Levene's Test (P > 0.05). ANOVA (P > 0.05) showed the absence of significant differences. There were significant differences in the instrumentation time (P < 0.05). For root canal anatomy preservation and non-instrumented areas, there were no significant differences between all systems (P > 0.05). The 4 different rotary systems produced similar cutting area, root canal anatomy preservation and non-instrumented areas. Regarding instrumentation time, F360(®) was the fastest system statistically.

22 September 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SASusana Aranda
Susana Aranda
APAntonio Pallarés-Sabater
Antonio Pallarés-Sabater
APAntonio Pallares-Serrano
Antonio Pallares-Serrano
JCJorge Rubio Climent
Jorge Rubio Climent
CACasino A.
Casino A.
Background: Endo-periodontal lesions (EPLs) are defined by a pathological connection between the pulp and the periodontium in a specific tooth. Although the identification of EPL etiology is of paramount importance for a correct treatment plan, it may be impossible at times to pinpoint the primary cause prospectively. A critical aspect of treatment planning involves assessing the necessity of root canal treatment in periodontal patients presenting with EPLs, evaluating the indication for periodontal intervention in cases of endodontic origin and determining whether splinting of the affected tooth is required. The aim of this article is to provide a concise perspective on the management of EPLs without root damage. Methods: A clinical decision-making flowchart was created based on current classification systems to guide treatment strategies for EPLs. Results: A flowchart of the treatment of EPLs based on possible decision pathways with a starting point in the diagnosis of the periodontitis or non-periodontitis patient that can prove particularly useful in cases where the initial etiology remains uncertain. Conclusions: EPLs are infections that represent a significant clinical challenge. This article summarizes key diagnostic considerations and therapeutic steps, offering practical guidance for clinicians managing these lesions.

3 November 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
CACasino Alegre A
Casino Alegre A
DLDalma Michell Ramírez López
Dalma Michell Ramírez López
MHManuel Monterde Hernández
Manuel Monterde Hernández
SASusana Aranda
Susana Aranda
JCJorge Rubio Climent
Jorge Rubio Climent
APAntonio Pallarés-Sabater
Antonio Pallarés-Sabater
Background: The development of calcium silicate materials and new techniques have resulted in significant clinical benefits in endodontics and microapical surgery. The objective of this investigation was to analyze the percentage of dentinal tubule penetration of two retrograde obturation techniques in microapical surgery, namely the conventional technique and the lid technique. Methods: 60 single-root human teeth were selected, which were divided into two groups (n = 30). These teeth were subjected to an endodontic procedure using the single-cone technique. They were prepared with apicoectomy and 3 mm apical retrocavity and then obturated using two retrograde obturation techniques with bioceramic materials: TotalFill RRM fast set Putty® (RRM) using the conventional technique and TotalFill BC Sealer HiFlow® (HiFlow) and RRM using the lid technique. The teeth were selected and evaluated using 1 mm portions in the apical third. In each case, the images were obtained using a Leica TCS SP8 Confocal Microscope (CLSM). The extent of penetration into the dentinal tubule regions was measured using AutoCad®. Results: Statistical analyses were performed using the Levene test (p ≤ 0.05) and Student’s t-test (p ≤ 0.05). Analysis of the penetration area of calcium silicate materials into the dentinal tubules revealed that the relative penetration percentages were higher when using the conventional technique with the RRM than the lid technique with RRM + HiFlow in the apical third evaluated. Conclusion: The conventional technique yields significantly better outcomes, showing statistically significant differences in the percentage of penetration into the intratubular area compared to the lid technique.