Michael S. Waring

Prof. Michael S. Waring


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

23 February 2014 in Indoor Air
Verified
Journal Article
Closed access
PDF file
MWMichael S. Waring
Michael S. Waring
Indoor secondary organic aerosol (SOA) formation may contribute to particle concentrations within residences, but little systematic work has investigated its magnitude or the determinants of its formation. This work uses a time-averaged modeling approach to predict the indoor SOA mass formed in residences due to the oxidation of 66 reactive organic compounds by ozone or the hydroxyl radical, parameterizing SOA formation with the aerosol mass fraction. Other organic and inorganic aerosols owing to outdoor and indoor sources were also predicted. Model inputs were represented as distributions within a Monte Carlo analysis, so that result distributions and sensitivity of results to inputs could be quantified, using a dataset developed from the study of Relationships between Indoor, Outdoor and Personal Air and other sources. SOA comprised a large amount of indoor organic and total fine particles for a subset of the results (e.g., >47% of indoor organic and >30% of fine aerosol for 10% of the modeled cases), but was often a small fraction. The sensitivity analysis revealed that SOA formation is driven by high terpene emission rates (particularly by d-limonene) and outdoor ozone, along with low air exchange and ozone and particle deposition rates. This study predicts that indoor SOA formation can be a substantial fraction of indoor aerosols in residences, for certain combinations of building and reactant parameters. The model herein can predict SOA for risk analyses or be used to design experiments to study indoor SOA formation. The terpene, d-limonene, contributes by far the most to formation, and eliminating this particular compound indoors would be impactful on indoor aerosol concentrations.

13 May 2013 in Environmental Science & Technology
Verified
Journal Article
Closed access
MWMichael S. Waring
Michael S. Waring
JSJeffrey A. Siegel
Jeffrey A. Siegel

6 November 2019 in Journal of Exposure Science & Environmental Epidemiology
Verified
Journal Article
Closed access
PDF file
BCBryan E. Cummings
Bryan E. Cummings
MWMichael S. Waring
Michael S. Waring

1 December 2010 in Indoor Air
Verified
Journal Article
Closed access
PDF file
MWMichael S. Waring
Michael S. Waring
JSJ. A. Siegel
J. A. Siegel
Ion generators charge particles with a corona prior to their removal on collector plates or indoor surfaces and also emit ozone, which can react with terpenes to yield secondary organic aerosol, carbonyls, carboxylic acids, and free radicals. This study characterized the indoor air quality implications of operating an ion generator in a 27 m3 residential room, with four different test room configurations. Two room configurations had carpet overlaying the original flooring of stained/sealed concrete, and for one configuration with and without carpet, a plug‐in air freshener was used as a terpene source. Measurements included airborne sampling of particulate matter (0.015–20 μm), terpenes and C1–C4 and C6–C10 aldehydes, ozone concentrations, and air exchange rates. When the heating, ventilating, and air‐conditioning system was not operating (room air exchange rate = ∼0.5/h), the use of the ion generator in the presence of the air freshener led to a net increase in ultrafine particles (<0.1 μm). Also, increased concentrations of ozone were observed regardless of air freshener presence, as well as increases in formaldehyde and nonanal, albeit within measurement uncertainty in some cases. Thus, it may be prudent to limit ion generator use indoors until evidence of safety can be ascertained. Portable ion generators are intended to clean the air of particles, but they may emit ozone as a byproduct of their operation, which has the potential to degrade indoor air quality. This study showed that under certain conditions in a residential room, the use of a portable ion generator can increase concentrations of ozone and, to a lesser degree, potentially aldehydes. Also, if operated in the presence of a plug‐in air freshener that emits terpenes, its use can increase concentrations of secondary organic aerosol in the ultrafine size range.

29 April 2019 in Environmental Science: Processes & Impacts
Verified
Journal Article
Closed access
PDF file
MSManabu Shiraiwa
Manabu Shiraiwa
NCNicola Carslaw
Nicola Carslaw
DTDouglas J. Tobias
Douglas J. Tobias
MWMichael S. Waring
Michael S. Waring
DRDonghyun Rim
Donghyun Rim
YWYoungbo Won
Youngbo Won
We report on the development of a modelling consortium for chemistry in indoor environments that connects models over a range of spatial and temporal scales, from molecular to room scales and from sub-nanosecond to days, respectively. Our modeling approaches include molecular dynamics (MD) simulations, kinetic process modeling, gas-phase chemistry modeling, organic aerosol modeling, and computational fluid dynamics (CFD) simulations. These models are applied to investigate ozone reactions with skin and clothing, oxidation of volatile organic compounds and formation of secondary organic aerosols, and mass transport and partitioning of indoor species to surfaces. MD simulations provide molecular pictures of limonene adsorption on SiO2 and ozone interactions with the skin lipid squalene, providing kinetic parameters such as surface accommodation coefficient, desorption lifetime, and bulk diffusivity. These parameters then constrain kinetic process models, which resolve mass transport and chemical reactions in gas and condensed phases for analysis of experimental data. A detailed indoor chemical box model is applied to simulate α-pinene ozonolysis with improved representation of gas–particle partitioning. Application of 2D-volatility basis set reveals that OH-induced aging sometimes drives increases in indoor organic aerosol concentrations, due to organic mass functionalization and enhanced partitioning. CFD simulations show that concentrations of ozone and primary product change near the human surface rapidly, indicating non-uniform spatial distributions from the occupant surface to ambient air, while secondary ozone product is relatively well-mixed throughout the room. This development establishes a framework to integrate different modeling tools and experimental measurements, opening up an avenue for development of comprehensive and integrated models with representations of various chemistry in indoor environments.