Nevio Luigi Tagliamonte

Dr. Nevio Luigi Tagliamonte

Research Unit of Advanced Robotics and Human-Centered Technologies – Università Campus Bio-Medico di Roma, 00128 Rome, Italy
+1
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2012 in Journal of Mechanical Design
Verified
Journal Article
Closed access
PDF file
GCGiorgio Carpino
Giorgio Carpino
Dino AccotoDino Accoto
Dino Accoto
FSFabrizio Sergi
Fabrizio Sergi
NTNevio Luigi Tagliamonte
Nevio Luigi Tagliamonte
EGEugenio Guglielmelli
Eugenio Guglielmelli
The introduction of intrinsic compliance in the actuation system of assistive robots improves safety and dynamical adaptability. Furthermore, in the case of wearable robots for gait assistance, the exploitation of conservative compliant elements as energy buffers can mimic the intrinsic dynamical properties of legs during locomotion. However, commercially available compliant components do not generally allow to meet the desired requirements in terms of admissible peak load, as typically required by gait assistance, while guaranteeing low stiffness and a compact and lightweight design. This paper presents a novel compact monolithic torsional spring to be used as the basic component of a modular compliant system for series elastic actuators. The spring, whose design was refined through an iterative FEA-based optimization process, has an external diameter of 85 mm, a thickness of 3 mm and a weight of 61.5 g. The spring, characterized using a custom dynamometric test bed, shows a linear torque versus angle characteristic. The compliant element has a stiffness of 98 N·m/rad and it is capable of withstanding a maximum torque of 7.68 N·m. A good agreement between simulated and experimental data were observed, with a maximum resultant error of 6%. By arranging a number of identical springs in series or in parallel, it is possible to render different torque versus angle characteristics, in order to match the specific applications requirements.

1 December 2012 in Mechatronics
Verified
Journal Article
Closed access
NTNevio Luigi Tagliamonte
Nevio Luigi Tagliamonte
FSFabrizio Sergi
Fabrizio Sergi
Dino AccotoDino Accoto
Dino Accoto
GCGiorgio Carpino
Giorgio Carpino
EGEugenio Guglielmelli
Eugenio Guglielmelli

8 January 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
CMC. Meijneke
C. Meijneke
GOG. van Oort
G. van Oort
VSVictor IJzebrand Sluiter
Victor IJzebrand Sluiter
EAE. van Asseldonk
E. van Asseldonk
NTNevio Luigi Tagliamonte
Nevio Luigi Tagliamonte
HKHerman Van Der Kooij
Herman Van Der Kooij
In this paper, we present the design, control, and preliminary evaluation of the Symbitron exoskeleton, a lower limb modular exoskeleton developed for people with a spinal cord injury. The mechanical and electrical configuration and the controller can be personalized to accommodate differences in impairments among individuals with spinal cord injuries (SCI). In hardware, this personalization is accomplished by a modular approach that allows the reconfiguration of a lower-limb exoskeleton with ultimately eight powered series actuated (SEA) joints and high fidelity torque control. For SCI individuals with an incomplete lesion and sufficient hip control, we applied a trajectory-free neuromuscular control (NMC) strategy and used the exoskeleton in the ankle-knee configuration. For complete SCI individuals, we used a combination of a NMC and an impedance based trajectory tracking strategy with the exoskeleton in the ankle-knee-hip configuration. Results of a preliminary evaluation of the developed hardware and software showed that SCI individuals with an incomplete lesion could naturally vary their walking speed and step length and walked faster compared to walking without the device. SCI individuals with a complete lesion, who could not walk without support, were able to walk with the device and with the support of crutches that included a push-button for step initiation Our results demonstrate that an exoskeleton with modular hardware and control allows SCI individuals with limited or no lower limb function to receive tailored support and regain mobility.

1 January 2013 in International Journal of Advanced Robotic Systems
Verified
Journal Article
Open access
Dino AccotoDino Accoto
Dino Accoto
GCGiorgio Carpino
Giorgio Carpino
FSFabrizio Sergi
Fabrizio Sergi
NTNevio Luigi Tagliamonte
Nevio Luigi Tagliamonte
LZLoredana Zollo
Loredana Zollo
EGEugenio Guglielmelli
Eugenio Guglielmelli
A safe interaction is crucial in wearable robotics in general, while in assistive and rehabilitation applications, robots may also be required to minimally perturb physiological movements, ideally acting as perfectly transparent machines. The actuation system plays a central role because the expected performance, in terms of torque, speed and control bandwidth, must not be achieved at the expense of lightness and compactness. Actuators embedding compliant elements, such as series elastic actuators, can be designed to meet the above-mentioned requirements in terms of high energy storing capacity and stability of torque control. A number of series elastic actuators have been proposed over the past 20 years in order to accommodate the needs arising from specific applications. This paper presents a novel series elastic actuator intended for the actuation system of a lower limb wearable robot, recently developed in our lab. The actuator is able to deliver 300 W and has a novel architecture making its centre of mass not co-located with its axis of rotation, for an easier integration into the robotic structure. A custom-made torsion spring with a stiffness of 272.25 N·m·rad– 1 is directly connected to the load. The delivered torque is calculated from the measurement of the spring deflection, through two absolute encoders. Testing on torque measurement accuracy and torque/stiffness control are reported.

1 June 2012
Verified
Conference Paper
Closed access
FSFabrizio Sergi
Fabrizio Sergi
Dino AccotoDino Accoto
Dino Accoto
GCGiorgio Carpino
Giorgio Carpino
NTNevio Luigi Tagliamonte
Nevio Luigi Tagliamonte
EGEugenio Guglielmelli
Eugenio Guglielmelli
In wearable robotics applications, actuators are required to satisfy strict constraints in terms of safety and controllability. The introduction of intrinsic compliance can help to meet both these requirements. However, the high torque and power necessary for robotic systems for gait assistance requires the use of custom elements, able to guarantee high performances with a compact and lightweight design. This paper presents a rotary Series Elastic Actuator (SEA), suitable to be used in an active orthosis for knee assistance during overground walking. The system includes a commercial flat brushless DC motor, a Harmonic Drive gear and a custom-designed torsion spring. Spring design has been optimized by means of an iterative FEM simulations-based process and can be directly connected to the output shaft, thus guaranteeing high torque fidelity. With a total weight of 1.8 kg, it is possible to directly include the actuator in the frame of a wearable orthosis for knee flexion/extension assistance. The presented design allows to obtain a large-force bandwidth of 5 Hz and to regulate output impedance in a range compatible to locomotion assistance of elderly subjects with an age-related decay of motor performances.

6 December 2013 in Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering
Verified
Journal Article
Closed access
NTNevio Luigi Tagliamonte
Nevio Luigi Tagliamonte
Dino AccotoDino Accoto
Dino Accoto
Robots operating in close contact with humans require actuators capable of accurately and safely modulating the delivered torque. To this aim, rotary series elastic actuators are largely adopted. Torque control is often implemented using a cascade control scheme involving proportional–integral regulators (velocity controller nested in a torque controller) for its simplicity and its potential of ensuring coupled stability. A high-level impedance control loop is also commonly added to regulate the interaction with the external agents. In the present work, conservative passivity conditions are derived when a cascade-controlled series elastic actuator is used to haptically display different models of virtual impedance. In particular, the case of a null impedance, of a pure spring and of series and parallel spring–damper systems (corresponding to standard linear viscoelastic bodies) are analyzed in order to derive design guidelines useful for the selection of the control gains as well as for determining the ranges of renderable virtual impedance.