Jorge Sancho

Mr. Jorge Sancho

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
DJDavid Hernando Jumilla
David Hernando Jumilla
SRSurya Roca
Surya Roca
JSJorge Sancho
Jorge Sancho
AAAlvaro Alesanco
Alvaro Alesanco
Raquel BailónRaquel Bailón
Raquel Bailón
Heart rate variability (HRV) analysis is a noninvasive tool widely used to assess autonomic nervous system state. The market for wearable devices that measure the heart rate has grown exponentially, as well as their potential use for healthcare and wellbeing applications. Still, there is a lack of validation of these devices. In particular, this work aims to validate the Apple Watch in terms of HRV derived from the RR interval series provided by the device, both in temporal (HRM (mean heart rate), SDNN, RMSSD and pNN50) and frequency (low and high frequency powers, LF and HF) domain. For this purpose, a database of 20 healthy volunteers subjected to relax and a mild cognitive stress was used. First, RR interval series provided by Apple Watch were validated using as reference the RR interval series provided by a Polar H7 using Bland-Altman plots and reliability and agreement coefficients. Then, HRV parameters derived from both RR interval series were compared and their ability to identify autonomic nervous system (ANS) response to mild cognitive stress was studied. Apple Watch measurements presented very good reliability and agreement (>0.9). RR interval series provided by Apple Watch contain gaps due to missing RR interval values (on average, 5 gaps per recording, lasting 6.5 s per gap). Temporal HRV indices were not significantly affected by the gaps. However, they produced a significant decrease in the LF and HF power. Despite these differences, HRV indices derived from the Apple Watch RR interval series were able to reflect changes induced by a mild mental stress, showing a significant decrease of HF power as well as RMSSD in stress with respect to relax, suggesting the potential use of HRV measurements derived from Apple Watch for stress monitoring.

1 February 2020 in Journal of Biomedical Informatics
Verified
Journal Article
Closed access
SRSurya Roca
Surya Roca
JSJorge Sancho
Jorge Sancho
José GarcíaJosé García
José García
AAAlvaro Alesanco
Alvaro Alesanco

11 May 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JSJorge Sancho
Jorge Sancho
AAAlvaro Alesanco
Alvaro Alesanco
José GarcíaJosé García
José García
The photoplethysmogram (PPG) is a biomedical signal that can be used to estimate volumetric blood flow changes in the peripheral circulation. During the past few years, several works have been published in order to assess the potential for PPGs to be used in biometric authentication systems, but results are inconclusive. In this paper we perform an analysis of the feasibility of using the PPG as a realistic biometric alternative in the long term. Several feature extractors (based on the time domain and the Karhunen–Loève transform) and matching metrics (Manhattan and Euclidean distances) have been tested using four different PPG databases (PRRB, MIMIC-II, Berry, and Nonin). We show that the false match rate (FMR) and false non-match rate (FNMR) values remain constant in different time instances for a selected threshold, which is essential for using the PPG for biometric authentication purposes. On the other hand, obtained equal error rate (EER) values for signals recorded during the same session range from 1.0% for high-quality signals recorded in controlled conditions to 8% for those recorded in conditions closer to real-world scenarios. Moreover, in certain scenarios, EER values rise up to 23.2% for signals recorded over different days, signaling that performance degradation could take place with time.

25 September 2019
Verified
Book Chapter
Closed access
PDF file
SRSurya Roca
Surya Roca
MHManuel Hernández
Manuel Hernández
JSJorge Sancho
Jorge Sancho
José GarcíaJosé García
José García
AAAlvaro Alesanco
Alvaro Alesanco

22 September 2020 in Security and Communication Networks
Verified
Journal Article
Open access
PDF file
JSJorge Sancho
Jorge Sancho
JGJosé García
José García
ÁAÁlvaro Alesanco
Álvaro Alesanco
In this work, we introduce the system boundary security vs. privacy dilemma, where border devices (e.g., firewall devices) require unencrypted data inspection to prevent data exfiltration or unauthorized data accesses, but unencrypted data inspection violates data privacy. To shortcut this problem, we present Oblivious Inspection, a novel approach based on garbled circuits to perform a stateful application-aware inspection of encrypted network traffic in a privacy-preserving way. We also showcase an inspection algorithm for Fast Healthcare Interoperability Resources (FHIR) standard compliant packets along with its performance results. The results point out the importance of the inspection function being aligned with the underlying garbled circuit protocol. In this line, mandatory encryption algorithms for TLS 1.3 have been analysed observing that packets encrypted using Chacha20 can be filtered up to 17 and 25 times faster compared with AES128-GCM and AES256-GCM, respectively. All together, this approach penalizes performance to align system security and data privacy, but it could be appropriate for those scenarios where this performance degradation can be justified by the sensibility of the involved data such as healthcare scenarios.

13 June 2017
Verified
Book Chapter
Closed access
PDF file
JSJorge Sancho
Jorge Sancho
AAAlvaro Alesanco
Alvaro Alesanco
JGJose Garca
Jose Garca