In this paper we assessed the possibility of using the pulse rate variability (PRV) extracted from the photoplethysmography signal as an alternative measurement of the HRV signal in non-stationary conditions. The study is based on analysis of the changes observed during a tilt table test in the heart rate modulation of 17 young subjects. First, the classical indices of HRV analysis were compared to the indices from PRV in intervals where stationarity was assumed. Second, the time-varying spectral properties of both signals were compared by time-frequency (TF) and TF coherence analysis. Third, the effect of replacing PRV with HRV in the assessment of the changes of the autonomic modulation of the heart rate was considered. Time-invariant HRV and PRV indices showed no statistically significant differences (p > 0.05) and high correlation (>0.97). Time-frequency analysis revealed that the TF spectra of both signals were highly correlated (0.99 +/- 0.01); the difference between the instantaneous power, in the LF and HF bands, obtained from HRV and PRV was small (<10(-3) s(-2)) and their temporal patterns were highly correlated (0.98 +/- 0.04 and 0.95 +/- 0.06 in the LF and HF bands, respectively) and TF coherence in the LF and HF bands was high (0.97 +/- 0.04 and 0.89 +/- 0.08, respectively). Finally, the instantaneous power in the LF band was observed to significantly increase during head-up tilt by both HRV and PRV analysis. These results suggest that although some differences in the time-varying spectral indices extracted from HRV and PRV exist, mainly in the HF band associated with respiration, PRV could be used as a surrogate of HRV during non-stationary conditions, at least during the tilt table test.
22 May 2013 in International Journal of Sports Medicine
The aims of this study were: to compare energy expenditure (EE) estimated from the existing GT3X accelerometer equations and EE measured with indirect calorimetry; to define new equations for EE estimation with the GT3X in youth, adults and older people; and to define GT3X vector magnitude (VM) cut points allowing to classify PA intensity in the aforementioned age-groups. The study comprised 31 youth, 31 adults and 35 older people. Participants wore the GT3X (setup: 1-s epoch) over their right hip during 6 conditions of 10-min duration each: resting, treadmill walking/running at 3, 5, 7, and 9 km · h−1, and repeated sit-stands (30 times · min−1). The GT3X proved to be a good tool to predict EE in youth and adults (able to discriminate between the aforementioned conditions), but not in the elderly. We defined the following equations: for all age-groups combined, EE (METs)=2.7406+0.00056 · VM activity counts (counts · min−1)−0.008542 · age (years)−0.01380 · body mass (kg); for youth, METs=1.546618+0.000658 · VM activity counts (counts · min−1); for adults, METs=2.8323+0.00054 · VM activity counts (counts · min−1)−0.059123 · body mass (kg)+1.4410 · gender (women=1, men=2); and for the elderly, METs=2.5878+0.00047 · VM activity counts (counts · min−1)−0.6453 · gender (women=1, men=2). Activity counts derived from the VM yielded a more accurate EE estimation than those derived from the Y-axis. The GT3X represents a step forward in triaxial technology estimating EE. However, age-specific equations must be used to ensure the correct use of this device.
Heart rate variability (HRV) analysis is a noninvasive tool widely used to assess autonomic nervous system state. The market for wearable devices that measure the heart rate has grown exponentially, as well as their potential use for healthcare and wellbeing applications. Still, there is a lack of validation of these devices. In particular, this work aims to validate the Apple Watch in terms of HRV derived from the RR interval series provided by the device, both in temporal (HRM (mean heart rate), SDNN, RMSSD and pNN50) and frequency (low and high frequency powers, LF and HF) domain. For this purpose, a database of 20 healthy volunteers subjected to relax and a mild cognitive stress was used. First, RR interval series provided by Apple Watch were validated using as reference the RR interval series provided by a Polar H7 using Bland-Altman plots and reliability and agreement coefficients. Then, HRV parameters derived from both RR interval series were compared and their ability to identify autonomic nervous system (ANS) response to mild cognitive stress was studied. Apple Watch measurements presented very good reliability and agreement (>0.9). RR interval series provided by Apple Watch contain gaps due to missing RR interval values (on average, 5 gaps per recording, lasting 6.5 s per gap). Temporal HRV indices were not significantly affected by the gaps. However, they produced a significant decrease in the LF and HF power. Despite these differences, HRV indices derived from the Apple Watch RR interval series were able to reflect changes induced by a mild mental stress, showing a significant decrease of HF power as well as RMSSD in stress with respect to relax, suggesting the potential use of HRV measurements derived from Apple Watch for stress monitoring.
Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology.
19 June 2006 in IEEE Transactions on Biomedical Engineering
A robust method is presented for electrocardiogram (ECG)-based estimation of the respiratory frequency during stress testing. Such ECGs contain highly nonstationary noise and exhibit changes in QRS morphology which, when combined with the dynamic nature of the respiratory frequency, make most existing methods break down. The present method exploits the oscillatory pattern of the rotation angles of the heart's electrical axis as induced by respiration. The series of rotation angles, obtained from least-squares loop alignment, is subject to power spectral analysis and estimation of the respiratory frequency. Robust techniques are introduced to handle the nonstationary properties of exercise ECGs. The method is evaluated by means of both simulated signals, and ECG/airflow signals recorded from 14 volunteers and 20 patients during stress testing. The resulting respiratory frequency estimation error is, for simulated signals, equal to 0.5% /spl plusmn/ 0.2%, mean /spl plusmn/ SD (0.002 /spl plusmn/ 0.001 Hz), whereas the error between respiratory frequencies of the ECG-derived method and the airflow signals is 5.9% /spl plusmn/ 4% (0.022 /spl plusmn/ 0.016 Hz). The results suggest that the method is highly suitable for analysis of noisy ECG signals recorded during stress testing.
21 September 2012 in Medical & Biological Engineering & Computing