Jianqiang Han

Dr. Jianqiang Han

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
JHJianqiang Han
Jianqiang Han
ZZZhengqian Zhao
Zhengqian Zhao
WNWenju Niu
Wenju Niu
RHRongyu Huang
Rongyu Huang
LDLizhen Dong
Lizhen Dong

17 April 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JHJianqiang Han
Jianqiang Han
YZYongsheng Zhu
Yongsheng Zhu
GTGonghao Tao
Gonghao Tao
ZZZhengqian Zhao
Zhengqian Zhao
YYYijun Yin
Yijun Yin
LDLizhen Dong
Lizhen Dong
This paper presents the design, simulation, fabrication and experiment of a triaxial accelerometer based on differential resonant beams and force-balanced capacitive plates. The triaxial accelerometer is composed of a proof mass, four bridge resonators with both end clamped and operating in flexure vibration mode, four L-type supporting beams, a top plate and a bottom plate. The in-plane acceleration are measured by bridge resonators. The gravity centre of the proof mass and the neutral layer of L-type supporting beams are located within a same plane to minimize the rotation of the proof mass subjected to in-plane acceleration. The cross-axis sensitivities of X-axis and Y-axis resonant beams under lateral in-plane acceleration are 1.97% and 1.71%, respectively. A force-balanced differential plate capacitor composed of a proof mass, a top plate and a bottom plate is used to detect acceleration along Z-axis. The small displacement of the proof mass in the normal direction of the chip reduces the cross-axis sensitivity of the bridge resonators subjected to acceleration along Z-axis. The complementation of resonance detection mechanism and the force balance capacitance mode makes the triaxial accelerometer exhibit low cross-axis sensitivity. The simulated and experimental results prove this conclusion.

21 May 2009 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
JHJianqiang Han
Jianqiang Han
SLShaoyong Lu
Shaoyong Lu
QLQing Li
Qing Li
XLXiaolu Li
Xiaolu Li
JWJiangying Wang
Jiangying Wang

3 February 2005 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
JHJianqiang Han
Jianqiang Han
ZCZhu Changchun
Zhu Changchun
LJLiu Junhua
Liu Junhua
PLPeng Li
Peng Li

1 March 2012 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JHJianqiang Han
Jianqiang Han
XWXiaofei Wang
Xiaofei Wang
TYTianhong Yan
Tianhong Yan
YLYan Li
Yan Li
MSMeixuan Song
Meixuan Song
Microcantilever with integrated piezoresistor has been applied to in situ surface stress measurement in the field of biochemical sensors. It is well known that piezoresistive cantilever-based sensors are sensitive to ambient temperature changing due to highly temperature-dependent piezoresistive effect and mismatch in thermal expansion of composite materials. This paper proposes a novel method of temperature drift compensation for microcantilever-based sensors with a piezoresistive full Wheatstone bridge integrated at the clamped ends by subtracting the amplified output voltage of the reference cantilever from the output voltage of the sensing cantilever through a simple temperature compensating circuit. Experiments show that the temperature drift of microcantilever sensors can be significantly reduced by the method.

1 September 2017 in Materials Research Express
Verified
Journal Article
Closed access
PDF file
JHJianqiang Han
Jianqiang Han
YYYi Jun Yin
Yi Jun Yin
DHDong Han
Dong Han
LDLiZhen Dong
LiZhen Dong
Although plasma enhanced chemical vapor deposition (PECVD) silicon nitride (Si x N y ) films have been extensively investigated by many researchers, requirements of film properties vary from device to device. For some applications utilizing Si x N y film as the mask Layer for deep wet etching of the silicon, it is very desirable to obtain a high quality film. In this study, Si x N y films were deposited on silicon substrates by PECVD technique from the mixtures of NH3 and 5% SiH4 diluted in Ar. The deposition temperature and RF power were fixed at 400 °C and 20 W, respectively. By adjusting the SiH4/NH3 flow ratio, Si x N y films of different compositions were deposited on silicon wafers. The stoichiometry, residual stress, etch rate in 1:50 HF, BHF solution and 40% KOH solution of deposited Si x N y films were measured. The experimental results show that the optimum SiH4/NH3 flow ratio at which deposited Si x N y films can perfectly protect the polysilicon resistors on the front side of wafers during KOH etching is between 1.63 and 2.24 under the given temperature and RF power. Polysilicon resistors protected by the Si x N y films can withstand 6 h 40% KOH double-side etching at 80 °C. At the range of SiH4/NH3 flow ratios, the Si/N atom ratio of films ranges from 0.645 to 0.702, which slightly deviate the ideal stoichiometric ratio of LPCVD Si3N4 film. In addition, the silicon nitride films with the best protection effect are not the films of minimum etch rate in KOH solution.