17 April 2019 in IEEE Sensors Journal
This paper presents the design, simulation, fabrication and experiment of a triaxial accelerometer based on differential resonant beams and force-balanced capacitive plates. The triaxial accelerometer is composed of a proof mass, four bridge resonators with both end clamped and operating in flexure vibration mode, four L-type supporting beams, a top plate and a bottom plate. The in-plane acceleration are measured by bridge resonators. The gravity centre of the proof mass and the neutral layer of L-type supporting beams are located within a same plane to minimize the rotation of the proof mass subjected to in-plane acceleration. The cross-axis sensitivities of X-axis and Y-axis resonant beams under lateral in-plane acceleration are 1.97% and 1.71%, respectively. A force-balanced differential plate capacitor composed of a proof mass, a top plate and a bottom plate is used to detect acceleration along Z-axis. The small displacement of the proof mass in the normal direction of the chip reduces the cross-axis sensitivity of the bridge resonators subjected to acceleration along Z-axis. The complementation of resonance detection mechanism and the force balance capacitance mode makes the triaxial accelerometer exhibit low cross-axis sensitivity. The simulated and experimental results prove this conclusion.
9 October 2018 in IEEE Sensors Journal
This paper presents the design, simulation, fabrication and experiment of a dual-axis bulk micromachined resonant accelerometer. The resonant accelerometer consists of a proof mass, four crab-leg supporting beams, and four resonant beams. Resonant beams are located at the surface of a silicon chip in order to pattern resistors and metal lines. The gravity centre of the proof mass basically lies within the neutral plane of crab-leg supporting beams to minimize the rotation of the proof mass under in-plane acceleration. The non-coplanar resonant beams and crab-leg supporting beams are formed simultaneously by masked–maskless wet etching in iodine-supersaturated KOH solution. The experimental results show that the cross-axis sensitivity of X-axis resonant beams under Y-axis acceleration is 1.92 % and that of Y-axis resonant beams under X-axis acceleration is 1.55%.
18 May 2018 in IEEE Transactions on Instrumentation and Measurement
This paper presents the design, fabrication, and preliminary results of a resonant thermal converter consisting of an electrothermally excited/piezoresistively detected SiO₂/Si₃N₄/SiₓNy microbridge resonator and a Ni24.9Cr72.5Si2.6 heating resistor placed on another beam parallel to the microbridge. The noncontact temperature sensing technique reduces the diversion of thermal energy from the temperature sensors, as well as the ac-dc transfer differences due to the capacitive coupling between the heater and the temperature sensor. The semidigital output of the resonant thin-film thermal converter eliminates problems such as intensity fluctuations associated with analog signals. The temperature coefficient of resistance of the Ni24.9Cr72.5Si2.6 film with a thickness of 89 nm is only -0.86 x 10⁻⁶/K. The responsivity of the resonant thermal converter is 9.21 kHz· W⁻¹ in air. The thermoelectric transfer difference measured by the fast-reversed dc method at 1 kHz is 2.8 x 10⁻⁶. It indicates that the resonant thermal converter is a promising thermal converter.