Lizhen Dong

Lizhen Dong

Auto-generated profile, based on publicly available information

Lizhen Dong

College of Mechanical & Electrical Engineering, China Jiliang University, Hangzhou, 310018, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JHJianqiang Han
Jianqiang Han
YZYongsheng Zhu
Yongsheng Zhu
GTGonghao Tao
Gonghao Tao
ZZZhengqian Zhao
Zhengqian Zhao
YYYijun Yin
Yijun Yin
LDLizhen Dong
Lizhen Dong
This paper presents the design, simulation, fabrication and experiment of a triaxial accelerometer based on differential resonant beams and force-balanced capacitive plates. The triaxial accelerometer is composed of a proof mass, four bridge resonators with both end clamped and operating in flexure vibration mode, four L-type supporting beams, a top plate and a bottom plate. The in-plane acceleration are measured by bridge resonators. The gravity centre of the proof mass and the neutral layer of L-type supporting beams are located within a same plane to minimize the rotation of the proof mass subjected to in-plane acceleration. The cross-axis sensitivities of X-axis and Y-axis resonant beams under lateral in-plane acceleration are 1.97% and 1.71%, respectively. A force-balanced differential plate capacitor composed of a proof mass, a top plate and a bottom plate is used to detect acceleration along Z-axis. The small displacement of the proof mass in the normal direction of the chip reduces the cross-axis sensitivity of the bridge resonators subjected to acceleration along Z-axis. The complementation of resonance detection mechanism and the force balance capacitance mode makes the triaxial accelerometer exhibit low cross-axis sensitivity. The simulated and experimental results prove this conclusion.

9 October 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WNWenju Niu
Wenju Niu
RHRongyu Huang
Rongyu Huang
JHJianqiang Han
Jianqiang Han
LDLizhen Dong
Lizhen Dong
This paper presents the design, simulation, fabrication and experiment of a dual-axis bulk micromachined resonant accelerometer. The resonant accelerometer consists of a proof mass, four crab-leg supporting beams, and four resonant beams. Resonant beams are located at the surface of a silicon chip in order to pattern resistors and metal lines. The gravity centre of the proof mass basically lies within the neutral plane of crab-leg supporting beams to minimize the rotation of the proof mass under in-plane acceleration. The non-coplanar resonant beams and crab-leg supporting beams are formed simultaneously by masked–maskless wet etching in iodine-supersaturated KOH solution. The experimental results show that the cross-axis sensitivity of X-axis resonant beams under Y-axis acceleration is 1.92 % and that of Y-axis resonant beams under X-axis acceleration is 1.55%.

18 May 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JHJianqiang Han
Jianqiang Han
RHRongyu Huang
Rongyu Huang
PZPeng Zhang
Peng Zhang
BCBing Cheng
Bing Cheng
LDLizhen Dong
Lizhen Dong
DHDong Han
Dong Han
This paper presents the design, fabrication, and preliminary results of a resonant thermal converter consisting of an electrothermally excited/piezoresistively detected SiO₂/Si₃N₄/SiₓNy microbridge resonator and a Ni24.9Cr72.5Si2.6 heating resistor placed on another beam parallel to the microbridge. The noncontact temperature sensing technique reduces the diversion of thermal energy from the temperature sensors, as well as the ac-dc transfer differences due to the capacitive coupling between the heater and the temperature sensor. The semidigital output of the resonant thin-film thermal converter eliminates problems such as intensity fluctuations associated with analog signals. The temperature coefficient of resistance of the Ni24.9Cr72.5Si2.6 film with a thickness of 89 nm is only -0.86 x 10⁻⁶/K. The responsivity of the resonant thermal converter is 9.21 kHz· W⁻¹ in air. The thermoelectric transfer difference measured by the fast-reversed dc method at 1 kHz is 2.8 x 10⁻⁶. It indicates that the resonant thermal converter is a promising thermal converter.