Opeyemi Taiwo Adeniran

Ms. Opeyemi Taiwo Adeniran

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2025 in Algorithms
Verified
Journal Article
Open access
PDF file
OAOpeyemi Taiwo Adeniran
Opeyemi Taiwo Adeniran
Blessing Onuwa OjemeBlessing Onuwa Ojeme
Blessing Onuwa Ojeme
TATemitope Ajibola
Temitope Ajibola
OPOjonugwa Ejiga Peter
Ojonugwa Ejiga Peter
AAAbiola Olayinka Ajala
Abiola Olayinka Ajala
Fahmi KhalifaFahmi Khalifa
Fahmi Khalifa
With the advancements in deep learning methods, AI systems now perform at the same or higher level than human intelligence in many complex real-world problems. The data and algorithmic opacity of deep learning models, however, make the task of comprehending the input data information, the model, and model’s decisions quite challenging. This lack of transparency constitutes both a practical and an ethical issue. For the present study, it is a major drawback to the deployment of deep learning methods mandated with detecting patterns and prognosticating Alzheimer’s disease. Many approaches presented in the AI and medical literature for overcoming this critical weakness are sometimes at the cost of sacrificing accuracy for interpretability. This study is an attempt at addressing this challenge and fostering transparency and reliability in AI-driven healthcare solutions. The study explores a few commonly used perturbation-based interpretability (LIME) and gradient-based interpretability (Saliency and Grad-CAM) approaches for visualizing and explaining the dataset, models, and decisions of MRI image-based Alzheimer’s disease identification using the diagnostic and predictive strengths of an ensemble framework comprising Convolutional Neural Networks (CNNs) architectures (Custom multi-classifier CNN, VGG-19, ResNet, MobileNet, EfficientNet, DenseNet), and a Vision Transformer (ViT). The experimental results show the stacking ensemble achieving a remarkable accuracy of 98.0% while the hard voting ensemble reached 97.0%. The findings present a valuable contribution to the growing field of explainable artificial intelligence (XAI) in medical imaging, helping end users and researchers to gain deep understanding of the backstory behind medical image dataset and deep learning model’s decisions.

9 March 2025 in Algorithms
Verified
Journal Article
Open access
PDF file
OPOjonugwa Ejiga Peter
Ojonugwa Ejiga Peter
OAOpeyemi Taiwo Adeniran
Opeyemi Taiwo Adeniran
AJAdetokunbo MacGregor John-Otumu
Adetokunbo MacGregor John-Otumu
Fahmi KhalifaFahmi Khalifa
Fahmi Khalifa
Md Mahmudur RahmanMd Mahmudur Rahman
Md Mahmudur Rahman
The lack of extensive, varied, and thoroughly annotated datasets impedes the advancement of artificial intelligence (AI) for medical applications, especially colorectal cancer detection. Models trained with limited diversity often display biases, especially when utilized on disadvantaged groups. Generative models (e.g., DALL-E 2, Vector-Quantized Generative Adversarial Network (VQ-GAN)) have been used to generate images but not colonoscopy data for intelligent data augmentation. This study developed an effective method for producing synthetic colonoscopy image data, which can be used to train advanced medical diagnostic models for robust colorectal cancer detection and treatment. Text-to-image synthesis was performed using fine-tuned Visual Large Language Models (LLMs). Stable Diffusion and DreamBooth Low-Rank Adaptation produce images that look authentic, with an average Inception score of 2.36 across three datasets. The validation accuracy of various classification models Big Transfer (BiT), Fixed Resolution Residual Next Generation Network (FixResNeXt), and Efficient Neural Network (EfficientNet) were 92%, 91%, and 86%, respectively. Vision Transformer (ViT) and Data-Efficient Image Transformers (DeiT) had an accuracy rate of 93%. Secondly, for the segmentation of polyps, the ground truth masks are generated using Segment Anything Model (SAM). Then, five segmentation models (U-Net, Pyramid Scene Parsing Network (PSNet), Feature Pyramid Network (FPN), Link Network (LinkNet), and Multi-scale Attention Network (MANet)) were adopted. FPN produced excellent results, with an Intersection Over Union (IoU) of 0.64, an F1 score of 0.78, a recall of 0.75, and a Dice coefficient of 0.77. This demonstrates strong performance in terms of both segmentation accuracy and overlap metrics, with particularly robust results in balanced detection capability as shown by the high F1 score and Dice coefficient. This highlights how AI-generated medical images can improve colonoscopy analysis, which is critical for early colorectal cancer detection.

8 August 2025 in arXiv
Verified
Preprint
Open access
PDF file
OPOjonugwa Ejiga Peter
Ojonugwa Ejiga Peter
AOAkingbola Oluwapemiisin
Akingbola Oluwapemiisin
ACAmalahu Chetachi
Amalahu Chetachi
OAOpeyemi Taiwo Adeniran
Opeyemi Taiwo Adeniran
Fahmi KhalifaFahmi Khalifa
Fahmi Khalifa
Md Mahmudur RahmanMd Mahmudur Rahman
Md Mahmudur Rahman
Colonoscopy is a vital tool for the early diagnosis of colorectal cancer, which is one of the main causes of cancer-related mortality globally; hence, it is deemed an essential technique for the prevention and early detection of colorectal cancer. The research introduces a unique multidirectional architectural framework to automate polyp detection within colonoscopy images while helping resolve limited healthcare dataset sizes and annotation complexities. The research implements a comprehensive system that delivers synthetic data generation through Stable Diffusion enhancements together with detection and segmentation algorithms. This detection approach combines Faster R-CNN for initial object localization while the Segment Anything Model (SAM) refines the segmentation masks. The faster R-CNN detection algorithm achieved a recall of 93.08% combined with a precision of 88.97% and an F1 score of 90.98%.SAM is then used to generate the image mask. The research evaluated five state-of-the-art segmentation models that included U-Net, PSPNet, FPN, LinkNet, and MANet using ResNet34 as a base model. The results demonstrate the superior performance of FPN with the highest scores of PSNR (7.205893) and SSIM (0.492381), while UNet excels in recall (84.85%) and LinkNet shows balanced performance in IoU (64.20%) and Dice score (77.53%).

2 August 2026
Verified
Book Chapter
Closed access
PDF file
OAOpeyemi Taiwo Adeniran
Opeyemi Taiwo Adeniran
KNKelechi Nwachukwu
Kelechi Nwachukwu
AAAnjolie Anthony
Anjolie Anthony
DNDavid Nyarko
David Nyarko
TATasmeer Alam
Tasmeer Alam
KNKofi Nyarko
Kofi Nyarko

3 January 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
OPOjonugwa Ejiga Peter
Ojonugwa Ejiga Peter
OAOpeyemi Taiwo Adeniran
Opeyemi Taiwo Adeniran
AJAdetokunbo MacGregor John-Otumu
Adetokunbo MacGregor John-Otumu
Fahmi KhalifaFahmi Khalifa
Fahmi Khalifa
Md Mahmudur RahmanMd Mahmudur Rahman
Md Mahmudur Rahman
The lack of extensive, varied, and thoroughly annotated datasets impedes the advancement of Artificial Intelligence (AI) for medical applications, specially colorectal cancer detection. Models trained with limited diversity often display biases, especially when utilized on disadvantaged groups. Generative models (e.g., DALL-E 2, VQ-GAN) ‘have been used to generate images, but not colonoscopy data for intelligent data augmentation. This study developed an effective method for producing synthetic colonoscopy image data, which can be used to train advanced medical diagnostic models for robust colorectal cancer detection and treatment. Text-to-image synthesis was performed using fine-tuned Visual LLMs. Stable Diffusion and DreamBooth Low Rank Adaptation produce images that look authentic, with an average Inception score of 2.36 across three datasets. The validation accuracy of various classification models– BiT, FixResNeXt, and EfficientNet– were 92%, 91%, and 86%, respectively. ViT and DeiT had an accuracy rate of 93%. Secondly, for the segmentation of polyps, the ground truth masks are generated using SAM. Then, five segmentation models (U-Net, PSNet, FPN, LinkNet, and MANet) were adopted. FPN produced excellent results, with an IoU of 0.64, an F1-score of 0.72, a recall of 0.87, and a Dice Coefficient of 0.72. This highlights how AI-generated medical images can improve colonoscopy analysis, which is critical for early colorectal cancer detection.