Manabu Sato

Prof. Manabu Sato


Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2006 in Optics Communications
Verified
Journal Article
Closed access
MSManabu Sato
Manabu Sato
TNTetsuo Nagata
Tetsuo Nagata
TNTakuya Niizuma
Takuya Niizuma
LNLiviu Neagu
Liviu Neagu
RDRazvan Dabu
Razvan Dabu
YWYuuki Watanabe
Yuuki Watanabe

9 January 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MSManabu Sato
Manabu Sato
KEKai Eto
Kai Eto
JMJunpei Masuta
Junpei Masuta
KIKenji Inoue
Kenji Inoue
RKReiko Kurotani
Reiko Kurotani
INIzumi Nishidate
Izumi Nishidate
We demonstrate full-field optical coherence microscopy (OCM) using an ultrathin forward-imaging short multimode fiber (SMMF) probe with a core diameter of 50 μm, outer diameter of 125 μm, and length of 7.4 mm, which is a typical graded-index multimode fiber used for optical communications. The axial and lateral resolutions were measured to be 2.14 μm and 2.3 μm, respectively. By inserting the SMMF 4 mm into the cortex of an in vivo rat brain, scanning was performed to a depth of 147 μm from the SMMF facet with a field of view of 47 μm. Three-dimensional (3D) OCM images were obtained at depths ranging from approximately 20 μm to 90 μm. Based on the morphological information of the resliced 3D images and the dependence of the integration of the OCM image signal on the insertion length, the obtained 3D information of nerve fibers has been presented.

22 July 2009 in Applied Optics
Verified
Journal Article
Closed access
PDF file
MSManabu Sato
Manabu Sato
MHMolly Subhash Hrebesh
Molly Subhash Hrebesh
INIzumi Nishidate
Izumi Nishidate
Three-dimensional (3D) optical coherence tomography (OCT) images of rat brain taken through the thinned skull were measured using quadrature fringe wide-field OCT (QF WF OCT) with a period of 10 min for total measurement time of 210 min stopping blood flow due to cardiac arrest, in order to investigate the potential of OCT to monitor tissue viability in brains. First, spatial resolution degradation was evaluated with QF WF OCT to demonstrate that the axial resolution was 390 μm at a thickness of 1000 μm. After cardiac arrest, the signal intensity in depth profiles increased 2.7 times compared with that before cardiac arrest. The ratio of signal intensity after euthanasia with an injection of pentobarbital sodium salt to that before sharply increased for 20 min, with stationary values of 2 to 4 overall. The trends of time variations of each position were similar. However, each stationary value depended on the 3D position.

Verified
Journal Article
Open access
PDF file
AMAfrina Mustari
Afrina Mustari
TKTakuya Kanie
Takuya Kanie
SKSatoko Kawauchi
Satoko Kawauchi
SSShunichi Sato
Shunichi Sato
MSManabu Sato
Manabu Sato
INIzumi Nishidate
Izumi Nishidate
During surgical treatment for cerebrovascular diseases, cortical hemodynamics are often controlled by bypass graft surgery, temporary occlusion of arteries, and surgical removal of veins. Since the brain is vulnerable to hypoxemia and ischemia, interruption of cerebral blood flow reduces the oxygen supply to tissues and induces irreversible damage to cells and tissues. Monitoring of cerebral hemodynamics and alteration of cellular structure during neurosurgery is thus crucial. Sequential recordings of red-green-blue (RGB) images of in vivo exposed rat brains were made during hyperoxia, normoxia, hypoxia, and anoxia. Monte Carlo simulation of light transport in brain tissue was used to specify relationships among RGB-values and oxygenated hemoglobin concentration (CHbO), deoxygenated hemoglobin concentration (CHbR), total hemoglobin concentration (CHbT), hemoglobin oxygen saturation (StO2), and scattering power b. Temporal courses of CHbO, CHbR, CHbT, and StO2 indicated physiological responses to reduced oxygen delivery to cerebral tissue. A rapid decrease in light scattering power b was observed after respiratory arrest, similar to the negative deflection of the extracellular direct current (DC) potential in so-called anoxic depolarization. These results suggest the potential of this method for evaluating pathophysiological conditions and loss of tissue viability.

18 April 2016 in Applied Optics
Verified
Journal Article
Closed access
PDF file
MSManabu Sato
Manabu Sato
KSKou Shouji
Kou Shouji
DSDaisuke Saito
Daisuke Saito
INIzumi Nishidate
Izumi Nishidate
We demonstrated the feasibility of an ultrathin imaging probe with a 50-μm core diameter, a 125 μm total diameter, and an 8.8 mm length, which is a typical graded-index multimode fiber for optical communications. We used an ABCD matrix to analyze the imaging conditions and magnification, which corresponded closely to the measured results. The lateral resolution was calculated at 1.2 μm with a wavelength of 730 nm, which reflects the image test pattern where a period of 4.38 μm was measured with a wavelength of 730 nm. In the numerical aperture of the objective lens, we experimentally evaluated the tradeoff between the magnification and the coupling efficiency. At four wavelengths of 540 nm, 632 nm, 730 nm, and 852 nm, the contrast and signal intensity versus the wavelength were investigated to show that the contrast at 632 and 730 nm is relatively high. By using a thin random phase screen model, we explained that as the wavelength decreases the greater the decrease in the optical transfer function at higher spatial frequencies. Using a 635 nm LED light source, we imaged the surfaces of chicken tendons in contact and the surface roughness was visible.

21 October 2016 in Optics Communications
Verified
Journal Article
Closed access
MSManabu Sato
Manabu Sato
KSKou Shouji
Kou Shouji
INIzumi Nishidate
Izumi Nishidate