Kenji Inoue

Dr. Kenji Inoue


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MSManabu Sato
Manabu Sato
KEKai Eto
Kai Eto
JMJunpei Masuta
Junpei Masuta
KIKenji Inoue
Kenji Inoue
RKReiko Kurotani
Reiko Kurotani
INIzumi Nishidate
Izumi Nishidate
We demonstrate full-field optical coherence microscopy (OCM) using an ultrathin forward-imaging short multimode fiber (SMMF) probe with a core diameter of 50 μm, outer diameter of 125 μm, and length of 7.4 mm, which is a typical graded-index multimode fiber used for optical communications. The axial and lateral resolutions were measured to be 2.14 μm and 2.3 μm, respectively. By inserting the SMMF 4 mm into the cortex of an in vivo rat brain, scanning was performed to a depth of 147 μm from the SMMF facet with a field of view of 47 μm. Three-dimensional (3D) OCM images were obtained at depths ranging from approximately 20 μm to 90 μm. Based on the morphological information of the resliced 3D images and the dependence of the integration of the OCM image signal on the insertion length, the obtained 3D information of nerve fibers has been presented.

12 August 2012 in Journal of Micro-Nano Mechatronics
Verified
Journal Article
Closed access
PDF file
KIKenji Inoue
Kenji Inoue
YMYuki Matsuzaki
Yuki Matsuzaki
SLSuwoong Lee
Suwoong Lee

2 October 2014 in Advanced Robotics
Verified
Journal Article
Closed access
KIKenji Inoue
Kenji Inoue
KUKentaro Ujiie
Kentaro Ujiie
SLSuwoong Lee
Suwoong Lee
A haptic device using flexible sheets for virtual training of abdominal palpation is proposed, mainly focusing on light and deep palpation. This device forms a semicylinder using two boards with rounded corners and two layered flexible sheets made of rubber. The device imitates the form of an abdomen. A trainee doctor touches and pushes everywhere of the upper sheet directly with his/her fingers and palm or single hand and both hands, regarding it as a virtual abdomen. Pulling the lower sheet lengthwise varies the softness of the sheet: the stretched sheet feels hard and the loose sheet feels soft. The trainee doctor can feel different softness of abdomens by pushing the device. Pulling the upper sheet in waistline direction depresses the centre of the device between the boards like a saddle. Stretching and loosening the upper sheet simulates up-and-down movement of an abdomen due to breathing. As a result, the trainee doctor can experience virtual abdominal palpation in the similar way as real palpation. The softness and depression at the centre of the device are measured for different tensions of the upper and lower sheets, and are compared with the measured softness and up-and-down movement due to breathing of real abdomens. A skilled physician evaluates that the device can present different softness in the range of softness of real abdomens and that the up-and-down movement of the device resembles that of real abdomens due to breathing. The empirical and sensory criterion of the physician is ascertained quantitatively using the device: he pushes abdomens until he feels the same reaction force, regardless of their softness.

10 March 2026 in Gels
Verified
Journal Article
Open access
PDF file
KIKenji Inoue
Kenji Inoue
ZFZhonggang Feng
Zhonggang Feng
YHYuta Higashiyama
Yuta Higashiyama
TKToshifumi Kawaguchi
Toshifumi Kawaguchi
TMTakehiro Matsuura
Takehiro Matsuura
MAMasaharu Abe
Masaharu Abe
Ensuring efficient nutrient delivery and waste removal within the interior of three-dimensional (3D) cultures remains a major challenge in tissue engineering. Here, we demonstrate a proof-of-concept methodology that creates internally distributed driving sources to enhance diffusion and perfusion within 3D constructs. Iron microparticles or iron-containing microtubes were incorporated into collagen gels used for the 3D culture of dermal or cardiac fibroblasts, and cyclic dynamic magnetic fields were applied to the constructs. Oscillatory motion of the iron particles enhanced diffusion within the gels, as evidenced by increases in the fast diffusion coefficient of more than threefold and the slow diffusion coefficient of more than tenfold under conditions suitable for cell culture. In cardiac fibroblast cultures, this enhancement significantly increased proliferation by approximately twofold and reduced cytotoxicity by half compared with controls. In contrast, no significant effects were observed in dermal fibroblast cultures. Cyclic compression of microtubes within the collagen gels induced by dynamic magnetic fields primarily resulted in cellular morphological changes, including a reduction in cell area to approximately 0.8-fold of the control values, increased cell polarization with the cellular aspect ratio rising from 1.4 to 1.9, and preferred cell orientations either parallel or perpendicular to the microtube axis. Together, these results suggest that this methodology has the potential to be developed as an effective strategy for improving diffusivity in 3D metabolic environments and for promoting angiogenesis in hydrogel-based cultures.

1 January 2020 in Transactions of the JSME (in Japanese)
Verified
Journal Article
Open access
PDF file
STShohei Tsukidate
Shohei Tsukidate
TKToshifumi Kawaguchi
Toshifumi Kawaguchi
KIKenji Inoue
Kenji Inoue
Non-contact manipulation of spherical micro objects using two facing glass micropipettes is proposed. One micropipette is on the left side of an object, and the other micropipette is on the right side. Each micropipette emits a jet of water and applies hydraulic pressure to the object. The center position of the object is always detected by microscopic image processing. For rotating the object, the micropipettes are arranged point symmetrically with respect to the center of the object and emit water jets. When the left micropipette is on the upper-left side of the object and the right micropipette is on the lower-right side, the object rotates clockwise. Exchanging the upper and lower positions of the micropipettes enables counterclockwise rotation. As the micropipettes come near the edge of the object, the object rotates faster. The micropipettes automatically keep the position relation of point symmetry even if the object moves during rotation; that allows continuous rotation. For moving the object, one or two micropipettes are used selectively according to the moving direction. When the moving direction is near horizontal, one micropipette is used. If the left micropipette is just besides the object and emits a water jet, the object moves right. As the left micropipette comes lower, the object moves in upper-right direction. When the moving direction is near vertical, the left and right micropipettes are used. If the micropipettes emit water jets at the both lower sides of the object, the object moves upward. In the same way, the object can be moved in all directions. The micropipettes automatically repeat rearrangement and water jet emission so as to compensate the error between the desired and actual moving directions. This feedback control enables the object to reach its goal position. The experimental results show that a glass bead with a diameter of about 120 μm can be rotated and moved to its goal position by the proposed method.

1 January 2016 in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
Verified
Journal Article
Open access
PDF file
YTYoshiki Takeda
Yoshiki Takeda
KIKenji Inoue
Kenji Inoue
A running method for our working six-legged robot is proposed. The robot has two legs at the front side of its body and four legs at the rear side. The four rear legs can kick the ground together, thus generating large propulsive force. Like bound running of quadrupeds, the robot runs by repeating two actions: 1) the robot kicks the ground with the rear legs and jumps forward, and 2) the robot moves its body forward with the front legs and lands the rear legs near the front legs. The robot is redesigned for running, and running poses are determined. Then a method of changing the running speed is proposed. Running performance is evaluated by experiments.