As the complexity of Low-Earth-Orbit (LEO) satellite tasks and their performance requirements increase, higher demands are placed on satellites’ ability to track mission trajectories, including their accuracy, speed, and capacity to resist external disturbances during operation. This paper proposes an anti-disturbance prescribed performance control scheme for LEO satellites. The scheme establishes a unified framework to accommodate the high-performance requirements of satellite observation, while also incorporating a disturbance observer within this framework to counteract unknown external disturbances. Unlike existing trajectory tracking control methods, the proposed control scheme allows for the flexible selection of performance functions to adapt to diverse satellite performance demands. By focusing on the distance between tracking errors and the performance function, this approach avoids the performance boundary issues faced by traditional prescribed performance control, thus preventing excessive energy consumption by the LEO satellite. Additionally, within the proposed control framework, a disturbance observer is implemented to provide real-time compensation for unknown disturbances while ensuring minimal control input usage for disturbance rejection. Our experimental results show that the proposed control scheme achieves consistent performance for the LEO satellite and successfully accomplishes mission trajectory tracking, even in the presence of unknown disturbances.
18 May 2020 in International Journal of Control, Automation, and Systems
The complexity of real‐world systems poses challenges to model‐based control, sparking significant interest in model‐free control methods. By depending exclusively on the system's input–output data, the proposed method eliminates the need to construct intricate internal system models. The implementation is straightforward, can satisfy bounded control inputs, and allows for arbitrary adjustment of the actuator's execution frequency. The proposed method establishes an iterative mechanism under the constraint of bounded control inputs. It guarantees the algorithm's convergence by ensuring the continuous narrowing of the control interval. Furthermore, the update conditions within the iterative strategy can adapt to extremely low and continuously adjusting actuator execution frequencies. The bounded stability of the control method is proven using the continuity definition of functions. Its effectiveness and feasibility are validated through simulation and experimental verification.
Hydrogen energy is developing rapidly, and the hydrogen-based integrated energy system (HIES) offers improved economic performance, flexibility, and environmental benefits compared with conventional power systems. However, the increasing frequency of natural disasters caused by climate change introduces significant vulnerabilities that threaten system security. Preventive scheduling provides a proactive and economical means to enhance system resilience against such uncertainties. This paper proposes a preventive scheduling model for HIES based on adaptive robust optimization (ARO) to address the uncertain impacts of natural disasters on transmission lines, pipelines, and roads. The model incorporates the operational constraints and interdependencies among multiple energy subsystems and integrates flexible scheduling strategies such as power-to-hydrogen-and-heat (P2HH) and hydrogen transportation (HT). A hybrid algorithm is developed to efficiently solve the large-scale ARO problem with numerous integer variables. Case studies performed on two test systems demonstrate that the proposed preventive scheduling model effectively reduces operational costs and load curtailments. Simulation results show that coordinating P2HH and HT reduces power, heat, hydrogen, and gas load curtailments by 14.35%, 43.39%, 49.97%, and 40.32%, respectively, as well as operational costs by 14.60%. Moreover, the proposed hybrid algorithm enhances computational efficiency, reducing solution time by 21% with only a 2% deviation from the solution obtained by the conventional C&CG–AOP algorithm.