The modelling of chlorine residual in water supply systems is of great importance in managing disinfectant concentrations throughout the network. First order decay kinetics are currently often used to describe both bulk and wall chlorine consumption. However, more complex approaches have been proposed, namely a parallel, two-reactant second order decay model (2R model) that has been reported as yielding better accuracy for simulating chlorine bulk decay in laboratory tests. The recent EPANET Multi-Species Extension (EPANET MSX) brought enhanced capabilities for the simulation of chlorine residuals in water supply systems, including the use of the 2R model or any other formulation. In the current paper, the performance of the 2R model as well as of first and nth order decay kinetics was assessed for full scale modelling of chlorine in a transmission system. Results have shown that a similar level of accuracy can be achieved with the three tested kinetic models, provided that a good calibration of the wall decay coefficient is accomplished. Although with improved modelling capabilities, the use of the stand- alone EPANET MSX was less user-friendly than normal EPANET application by the lack of a graphical interface allowing for the visualization of chlorine concentration profiles along the system. The use of the 3D-enabled Epanet Java web application circumvented such limitations. This tool together with a better characterization and estimation of the bulk and wall decay components allow for a more practical and accurate modelling of chlorine in water supply systems, while taking advantage of EPANET MSX's enhanced capabilities
The use of adequate decay models for simulating chlorine residuals can effectively aid in chlorine management in water supply systems. In this paper, wall decay in a full-scale water supply system is assessed and modelled using the traditional first-order (FO) model and the recent EXPBIO model. The EXPBIO model was successfully implemented in EPANET-MSX for the first time and predicted chlorine residuals with high accuracy. However, in the tested conditions (chlorine residuals ≥0.55 mg/L and small wall decay rates), the FO and the EXPBIO models described chlorine wall decay with similar accuracy. The results suggest that in systems of large diameter pipes and of high disinfectant concentrations, the simpler FO model can be used for the modelling of chlorine residuals without significant loss of accuracy. Further research is needed to identify in which conditions (chlorine levels, wall decay rates) the EXPBIO model performance may exceed that of the FO model.
Temperature is one of the factors that most influences chlorine decay rates in drinking water systems. The current paper assesses and demonstrates the importance of using a temperature dependent chlorine bulk decay model for the accurate prediction of disinfectant residuals in water supply systems. Chlorine concentration in a water transmission system was modelled for two seasons using a temperature-dependent bulk decay model at a constant and variable temperature. Results show that water temperature can vary within the system and that the accurate prediction of residuals may additionally require the incorporation of a water temperature model in the simulators. In this case study such approach was developed innovatively by establishing a water-age-dependent temperature function.
The current paper proposes a novel methodology for near–real time burst location and sizing in water distribution systems (WDS) by means of Multi–Layer Perceptron (MLP), a class of artificial neural network (ANN). The proposed methodology can be systematized in four steps: (1) construction of the pipe–burst database, (2) problem formulation and ANN architecture definition, (3) ANN training, testing and sensitivity analyses, (4) application based on collected data. A large database needs to be constructed using 24 h pressure–head data collected or numerically generated at different sensor locations during the pipe burst occurrence. The ANN is trained and tested in a real–life network, in Portugal, using artificial data generated by hydraulic extended period simulations. The trained ANN has demonstrated to successfully locate 60–70% of the burst with an accuracy of 100 m and 98% of the burst with an accuracy of 500 m and to determine burst sizes with uncertainties lower than 2 L/s in 90% of tested cases and lower than 0.2 L/s in 70% of the cases. This approach can be used as a daily management tool of water distribution networks (WDN), as long as the ANN is trained with artificial data generated by an accurate and calibrated WDS hydraulic models and/or with reliable pressure–head data collected at different locations of the WDS during the pipe burst occurrence.
Urban green spaces can be intensive water and energy consumers in the cities, particularly in water scarce regions. Though a very efficient use of such resources is necessary, tools for assessing both water and energy consumption and efficiency are not available. In this paper, a new methodology based on water and energy balances is developed for assessing the water-use and energy efficiency in urban green spaces. The proposed balances, adapted from those developed for water supply systems, are specifically tailored for accounting for urban green spaces specificities, namely, landscape water requirements, other uses besides irrigation and over irrigation water losses. The methodology is demonstrated in two case studies of different nature and characteristics: a modern garden with a smart irrigation system and an urban park with traditional irrigation system. The results show that the developed water balances allow to estimate and assess the irrigation efficiency over the years and to assess the effectiveness of implemented water saving measures. The application of the water–energy balance demonstrates the impact of water efficiency measures on the energy efficiency of the irrigation systems. The proposed methodology can be used to assess water and water–energy efficiency in urban green spaces and to identify the most adequate improvement measures, contributing for a better management of the two resources in the cities.