Over the past decade, an increasing body of evidence has suggested that three-dimensional (3-D) Monte Carlo (MC) light transport simulations are affected by the inherent limitations and errors of voxel-based domain boundaries. In this work, we specifically address this challenge using a hybrid MC algorithm, namely split-voxel MC or SVMC, that combines both mesh and voxel domain information to greatly improve MC simulation accuracy while remaining highly flexible and efficient in parallel hardware, such as graphics processing units (GPU). We achieve this by applying a marching-cubes algorithm to a pre-segmented domain to extract and encode sub-voxel information of curved surfaces, which is then used to inform ray-tracing computation within boundary voxels. This preservation of curved boundaries in a voxel data structure demonstrates significantly improved accuracy in several benchmarks, including a human brain atlas. The accuracy of the SVMC algorithm is comparable to that of mesh-based MC (MMC), but runs 2x-6x faster and requires only a lightweight preprocessing step. The proposed algorithm has been implemented in our open-source software and is freely available at http://mcx.space.
Since the initial release of the first open-source Monte Carlo (MC) light transport simulator—MCML1—nearly 30 years ago, MC-based photon simulations have been playing important roles amongst the biophotonics research community to facilitate the design and optimization of novel imaging instrumentation and image reconstruction, as well as providing gold-standard solutions for validating novel algorithms and data analysis pipelines. Notably, in the last decade, a list of free and open-source MC simulators have been published and further improved upon by their respective authors. The proliferation of open-source MC tools provides the community with abundant options to meet diverse needs arising in biophotonics research.
The mesh-based Monte Carlo (MMC) technique has grown tremendously since its initial publication nearly a decade ago. It is now recognized as one of the most accurate Monte Carlo (MC) methods, providing accurate reference solutions for the development of novel biophotonics techniques. In this work, we aim to further advance MMC to address a major challenge in biophotonics modeling, i.e. light transport within highly complex tissues, such as dense microvascular networks, porous media and multi-scale tissue structures. Although the current MMC framework is capable of simulating light propagation in such media given its generality, the run-time and memory usage grow rapidly with increasing media complexity and size. This greatly limits our capability to explore complex and multi-scale tissue structures. Here, we propose a highly efficient implicit mesh-based Monte Carlo (iMMC) method that incorporates both mesh- and shape-based tissue representations to create highly complex yet memory-efficient light transport simulations. We demonstrate that iMMC is capable of providing accurate solutions for dense vessel networks and porous tissues while reducing memory usage by greater than a hundred- or even thousand-fold. In a sample network of microvasculature, the reduced shape complexity results in nearly 3x speed acceleration. The proposed algorithm is now available in our open-source MMC software at http://mcx.space/#mmc.
With the rapidly evolving computational capabilities of modern central processing units (CPUs) and graphics processing units (GPUs), the Monte Carlo (MC) method1 has taken an increasingly important role in understanding complex photon–tissue interactions in biomedical optics applications. The increasing popularity of MC is largely due to its superior generality and high scalability in computation.2 As a stochastic solver to the radiative transfer equation, MC is capable of dealing with general complex media, such as low-scattering tissues, e.g., synovial fluids in the joint, air pockets in the lung, and cerebrospinal fluid (CSF) in the brain, or highly absorbing organs, such as livers, without compromising accuracy due to the use of approximations. The intuitive simulation strategies also allow easy adaptation for a wide-range of applications.2
Polarized light has been found to be highly sensitive to medium structures and hence has been widely adopted in optical imaging to probe microstructural features inside biological tissues.1–4 For example, the polarization status of the backscattered light can be measured to characterize the superficial layer of skin for cancer diagnostic purposes.5,6 The measurements of tissue birefringence permit quantification of abnormalities of the retinal nerve fiber layer7 and cornea,8 as well as three-dimensional (3D) reconstruction of nerve fiber orientations inside human brains9 and orientations of collagen within the uterine cervix.10 By measuring the unequal absorption of left-handed and right-handed circularly polarized light, circular dichroism can rapidly determine the folding properties of proteins.11 Quantification of collagen and birefringent media alignment can improve evaluation of a therapeutic strategy and its outcome in scar management.12 Polarized light imaging (PLI) uses linearly co-polarized images subtracted by those of cross-polarized light to create a differential image based on the small population of superficially scattered photons that still retain much of the incident polarization state.5 PLI subtracts the large randomized population of multiple-scattered photons that produce a blinding background of diffuse light. The resulting difference image enhances the contrast of superficial tissue layers and rejects deeper tissue structures, enabling wide-field screening of epidermal or epithelial layers. Mueller matrix polarimetry and the use of various decomposition methods can also be used to pinpoint different regions and structures within biological tissue.2,3 Accurately simulating polarized light transport inside complex tissues allow quantitative investigations of the depth response of polarized light and the perturbations produced by local tissue abnormalities.
The increasing use of spatially modulated imaging and single-pixel detection techniques demands computationally efficient methods for light transport modeling. Herein, we report an easy-to-implement yet significantly more efficient Monte Carlo (MC) method for simultaneously simulating spatially modulated illumination and detection patterns accurately in 3D complex domains. We have implemented this accelerated algorithm, named “photon sharing,” in our open-source MC simulators, reporting and speedups in mesh- and voxel-based MC benchmarks, respectively. In addition, the proposed algorithm is readily used to accelerate the solving of inverse problems in spatially modulated imaging systems by building Jacobians of all illumination-detection pattern pairs concurrently, resulting in a 12.4-fold speed improvement.