Jessica Ramella

Dr. Jessica Ramella

Department of Biomedical Engineering and Herbert Wertheim College of Medicine, Florida International University, Miami, FL 33174, USA
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2002 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
SJSteven Jacques
Steven Jacques
Jessica RamellaJessica Ramella
Jessica Ramella
KLKen Lee
Ken Lee
Linearly polarized light that illuminates skin is backscattered by superficial layers and rapidly depolarized by birefringent collagen fibers. It is possible to distinguish such superficially backscattered light from the total diffusely reflected light that is dominated by light penetrating deeply into the dermis. The method involves acquisition of two images through an analyzing linear polarizer in front of the camera, one image (Ipar) acquired with the analyzer oriented parallel to the polarization of illumination and one image (Iper) acquired with the analyzer oriented perpendicular to the illumination. An image based on the polarization ratio, Pol=(Ipar−Iper)/(Ipar+Iper), is created. This paper compares normal light images, represented by Iper, and Pol images of various skin pathologies in a pilot clinical study using incoherent visible-spectrum light. Images include pigmented skin sites (freckle, tattoo, pigmented nevi) and unpigmented skin sites [nonpigmented intradermal nevus, neurofibroma, actinic keratosis, malignant basal cell carcinoma, squamous cell carcinoma, vascular abnormality (venous lake), burn scar]. Images of a shadow cast from a razor blade onto a forearm skin site illustrate the behavior of Pol values near the shadow edge. Near the shadow edge, Pol approximately doubles in value because no Iper photons are superficially scattered into the shadow-edge pixels by the shadow region while Ipar photons are directly backscattered from the superficial layer of these pixels. This result suggests that the point spread function in skin for cross-talk between Pol pixels has a half-width-half-max of about 390 μm. © 2002 Society of Photo-Optical Instrumentation Engineers.

16 April 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
JFJesse Fine
Jesse Fine
KBKimberly Branan
Kimberly Branan
ARAndres J. Rodriguez
Andres J. Rodriguez
TBTananant Boonya-Ananta
Tananant Boonya-Ananta
AJAjmal
Ajmal
GCGerard Cote
Gerard Cote
Photoplethysmography (PPG) is a low-cost, noninvasive optical technique that uses change in light transmission with changes in blood volume within tissue to provide information for cardiovascular health and fitness. As remote health and wearable medical devices become more prevalent, PPG devices are being developed as part of wearable systems to monitor parameters such as heart rate (HR) that do not require complex analysis of the PPG waveform. However, complex analyses of the PPG waveform yield valuable clinical information, such as: blood pressure, respiratory information, sympathetic nervous system activity, and heart rate variability. Systems aiming to derive such complex parameters do not always account for realistic sources of noise, as testing is performed within controlled parameter spaces. A wearable monitoring tool to be used beyond fitness and heart rate must account for noise sources originating from individual patient variations (e.g., skin tone, obesity, age, and gender), physiology (e.g., respiration, venous pulsation, body site of measurement, and body temperature), and external perturbations of the device itself (e.g., motion artifact, ambient light, and applied pressure to the skin). Here, we present a comprehensive review of the literature that aims to summarize these noise sources for future PPG device development for use in health monitoring.

1 January 2005 in Optics Express
Verified
Journal Article
Closed access
PDF file
Jessica RamellaJessica Ramella
Jessica Ramella
SPScott A. Prahl
Scott A. Prahl
SJSteve L. Jacques
Steve L. Jacques
Propagation of light into scattering media is a complex problem that can be modeled using statistical methods such as Monte Carlo. Few Monte Carlo programs have so far included the information regarding the status of polarization of light before and after a scattering event. Different approaches have been followed and limited numerical values have been made available to the general public. In this paper, three different ways to build a Monte Carlo program for light propagation with polarization are given. Different groups have used the first two methods; the third method is original. Comparison in between Monte Carlo runs and Adding Doubling program yielded less than 1 % error.

1 November 2023 in Physiological Measurement
Verified
Journal Article
Open access
Peter CharltonPeter Charlton
Peter Charlton
John AllenJohn Allen
John Allen
Raquel BailónRaquel Bailón
Raquel Bailón
SBStephanie Baker
Stephanie Baker
JBJoachim A Behar
Joachim A Behar
TZTingting Zhu
Tingting Zhu
Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology.

11 November 2020 in Journal of Optics
Verified
Journal Article
Closed access
Jessica RamellaJessica Ramella
Jessica Ramella
ISIlyas Saytashev
Ilyas Saytashev
MPMattia Piccini
Mattia Piccini
Polarization-based imaging can provide new diagnostic capabilities in clinical and preclinical studies. Various methodologies of increasing complexity have been proposed by different groups in the last 30 years. In this review we focus on the most widely used methods in polarization imaging including co- and cross-polarized-based imaging, Mueller matrix imaging, and polarization sensitive optical coherence tomography, among others. This short primer in optical instrumentation for polarization-based imagery is aimed at readers interested in including polarization in their imaging processes.

1 January 2005 in Optics Express
Verified
Journal Article
Closed access
PDF file
Jessica RamellaJessica Ramella
Jessica Ramella
SPScott A. Prahl
Scott A. Prahl
SJSteven L. Jacques
Steven L. Jacques
Three Monte Carlo programs were developed which keep track of the status of polarization of light traveling through mono-disperse solutions of micro-spheres. These programs were described in detail in our previous article [1]. This paper illustrates a series of Monte Carlo simulations that model common experiments of light transmission and reflection of scattering media. Furthermore the codes were expanded to model light propagating through poly-disperse solutions of micro-spheres of different radii distributions.