1 April 2015 in Orthopedics
The number of total knee arthroplasty (TKA) procedures continuously increases, with good to excellent results. In the last few years, new surgical techniques have been developed to improve prosthesis positioning. In this context, patient-specific instrumentation is included. The goal of this study was to compare the perioperative parameters and the spatial positioning of prosthetic components in TKA procedures performed with patient-specific instrumentation vs traditional TKA. In this prospective comparative randomized study, 15 patients underwent TKA with 3-dimensional magnetic resonance imaging (MRI) preoperative planning (patient-specific instrumentation group) and 15 patients underwent traditional TKA (non–patient-specific instrumentation group). All patients underwent postoperative computed tomography (CT) examination. In the patient-specific instrumentation group, preoperative data planning regarding femoral and tibial bone resection was correlated with intraoperative measurements. Surgical time, length of hospitalization, and intraoperative and postoperative bleeding were compared between the 2 groups. Positioning of implants on postoperative CT was assessed for both groups. Data planned with 3-dimensional MRI regarding the depth of bone cuts showed good to excellent correlation with intraoperative measurements. The patient-specific instrumentation group showed better perioperative outcomes and good correlation between the spatial positioning of prosthetic components planned preoperatively and that seen on postoperative CT. Less variability was found in the patient-specific instrumentation group than in the non–patient-specific instrumentation group in spatial orientation of prosthetic components. Preoperative planning with 3-dimensional MRI in TKA has a better perioperative outcome compared with the traditional method. Use of patient-specific instrumentation can also improve the spatial positioning of both prosthetic components. [ Orthopedics. 2015; 38(4):e271–e280.]
22 November 2013 in European Radiology
4 March 2019 in La radiologia medica
1 September 2019 in Clinical Radiology
15 July 2015 in Acta Radiologica
Background Correct alignment of prosthetic components is the most important factor for the success of total knee arthroplasty (TKA). Dual-energy computed tomography (DECT) may be a reliable method in determining implant position after TKA. Purpose To evaluate the accuracy and reproducibility of DECT in determining implant position after TKA. Material and Methods Institutional review board approval was obtained. Forty-five patients (age 75.2 ± 6.4 years) prospectively underwent TKA at our institution between May and December 2012. DECT was performed 1 year after surgery, using an alignment similar to a standing position and generating images at an extrapolated energy of 120 kVp, in order to reduce metal artifacts. Implant position was evaluated by two independent readers. Intra- and inter-observer agreements were calculated. DECT measurements on implant position were compared with the preoperative planning based on radiographs. Additional clinical and DECT findings were taken into account. Results Metal artifact reduction was judged satisfactory in all cases. Regarding implant position assessed with DECT, good to excellent intra-observer (k: 0.74–0.87 and k: 0.75–0.88, respectively), and inter-observer agreement (k: 0.72–0.82) were found. In the comparison with preoperative planning, the widest limits of agreement were within 3.9° for the sagittal orientation of tibial component. A single patient with postoperative knee pain and stiffness had periprosthetic osteopenia, quadriceps femoris tendon calcifications, articular effusion, and excessive intrarotation of the femoral component. Conclusion DECT is an accurate and reproducible tool for determining implant position after TKA.