Background: The choice of software package (SP) for image processing affects the reproducibility of myocardial blood flow (MBF) values in [13N]NH3 PET/CT scans. However, the impact of motion correction (MC) tools—integrated software motion correction (ISMC) or data-driven motion correction (DDMC)—on the inter-software reproducibility of MBF has not been studied. This research aims to evaluate reproducibility among three commonly used SPs and the role of MC. Methods: Thirty-six PET/CT studies from patients without myocardial ischemia or infarction were processed using QPET, Corridor-4DM (4DM), and syngo.MBF (syngo). MBF and coronary flow reserve (CFR) values were obtained without motion correction (NMC) and with ISMC and DDMC. Intraclass correlation coefficients (ICC) and Bland-Altman (BA) plots were used to analyze agreement. Results: Good or excellent reproducibility (ICC ≥ 0.77) was found for rest-MBF values, regardless of the SPs or use of MC. In contrast, stress-MBF and CFR values presented mostly a moderate agreement when NMC was used. The RCA territory consistently had the lowest agreement in stress-MBF and CFR in the comparisons involving QPET. The use of MC, particularly DDMC, enhanced the reproducibility of most of the stress-MBF and CFR values by improving ICCs and reducing bias and limits of agreement (LoA) in BA analysis. Conclusions: MBF quantification agreement between SPs is strong for rest-MBF values but suboptimal for stress-MBF and CFR values. MC tools, especially DDMC, are recommended for improving reproducibility in stress-MBF assessments, although differences in SP reproducibility up to 0.77 mL/g/min in global stress-MBF and up to 0.88 in global CFR remain despite the use of MC.
Aim: The value of exercise electrocardiogram (ExECG) in symptomatic female patients with low to intermediate risk for significant coronary artery disease (CAD) has been under debate for many years, and nondiagnostic or even erroneous test results are frequently encountered. Cardiac-CT may be more appropriate to exclude CAD in women. This study compares the results of ExECGs with those of cardiac-CTs, performed within a time frame of 1 month in an all-comers female chest pain population. Patients and Methods: Five hundred fifty-one consecutive female patients from a patient registry were included. ExECGs were negative in 324 (59%), positive in 14 (3%), and nondiagnostic in 213 (39%) patients. CAD was revealed by cardiac-CT in 57% of the women with negative ExECG. No signs of CAD were present on cardiac-CT in 64% of the women with a positive ExECG. Cardiac-CT showed presence of CAD in 268/551 (49%) patients, of whom 56/268 (21%) was diagnosed with ≥50% stenosis. The ExECG of the latter group was negative in 26 (46%), inconclusive in 29 (52%), and positive in 1 (2%). Considering ≥50% stenosis at cardiac-CT as the reference, sensitivity, specificity, PPV, and NPV of ExECG for the present population were 3.7%, 95.7%, 7.1%, and 91.7%, respectively. Similar diagnostic performance was calculated when considering ≥70% stenosis at cardiac-CT as the reference. Conclusion: ExECG failed to detect CAD in more than half of this cohort and in almost half of women with >50% stenosis at cardiac-CT. Importantly, no CAD was detected by cardiac-CT in 64% of women with a positive ExECG. ExECG is therefore questionable as a diagnostic strategy in women with low-to-intermediate risk of CAD, although prospective studies are warranted to determine whether replacing ExECG by cardiac-CT provides better prognoses.
Background: Motion is a long-standing problem in cardiac PET/CT. An automated data-driven motion correction (DDMC) algorithm for within-reconstruction motion correction (MC) has been developed and validated in static images from [13N]NH3 and 82Rb PET/CT. This study aims to validate DDMC in dynamic [13N]NH3 PET/CT, and to explore the added value of DDMC in the evaluation of myocardial motion. Methods: Thirty-six PET/CT studies from normal patients and forty-three scans from patients with myocardial ischemia were processed using QPET software without MC (NMC), using manual in-software MC (ISMC), and DDMC. Differences in the mean values of rest-, stress-MBF, and CFR; and differences in effect size related to the use and type of MC method were explored. Moreover, motion vectors provided by DDMC were analyzed to evaluate differences in myocardial motion between scan phases and axes, and to elucidate changes in MBF quantification in relation to the motion extent. Results: In both subgroups, repeated measures ANOVA showed that the use of MC significantly increased regional and global stress-MBF and CFR values (p < 0.05), regardless of the MC method. Paired t-test analysis demonstrated a comparable ES between MC tools, despite minor differences in Cx, RCA and global rest-MBF values. High-intensity motion (>6 mm) proved to be present almost exclusively in the Z (cranio-caudal) direction. In the same axis, motion was significantly higher during stress than rest, regardless of patients’ subgroup. Finally, the Jonckheere trend test showed a significant trend caused by motion in s-MBF values, in which lower stress-MBF values were observed in response to motion extent increments. Conclusions: DDMC is feasible to perform in [13N]NH3 dynamic acquisitions and provides similar MBF/CFR values than manual ISMC. The use of DDMC reduces post-processing times and observer variability, and allows a more extensive evaluation of motion. MC is highly recommended when using QPET, as motion in the Z-axis during stress scans negatively impacts stress-MBF quantification.
A 37-year-old male personal trainer presented with debilitating groin pains, fever, and night sweats. Enlarged inguinal lymph nodes were noticed during physical examination, and blood tests showed elevated erythrocyte sedimentation rate and C-reactive protein. 18F-FDG PET/CT excluded lymphoma and other malignancy but showed intense FDG uptake at the pubic symphysis and cortical erosions of the pubic bones on CT. The patient was diagnosed with osteitis pubis, an inflammatory condition of the pubic symphysis commonly seen in athletes. Treatment with anti-inflammatory drugs was initiated. Within several weeks, pain decreased, and inflammatory markers normalized.