T. Samara Martinez-Lucio

Dr. T. Samara Martinez-Lucio


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2023 in British Journal of Radiology
Verified
Journal Article
Open access
HTHendrea Sanne Aletta Tingen
Hendrea Sanne Aletta Tingen
Gijs van PraaghGijs van Praagh
Gijs van Praagh
PNPieter H. Nienhuis
Pieter H. Nienhuis
ATAlwin Tubben
Alwin Tubben
NRNick van Rijsewijk
Nick van Rijsewijk
Riemer H.J.A. SlartRiemer H.J.A. Slart
Riemer H.J.A. Slart
Cardiovascular diseases (CVD) are the leading cause of death worldwide and have an increasing impact on society. Precision medicine, in which optimal care is identified for an individual or a group of individuals rather than for the average population, might provide significant health benefits for this patient group and decrease CVD morbidity and mortality. Molecular imaging provides the opportunity to assess biological processes in individuals in addition to anatomical context provided by other imaging modalities and could prove to be essential in the implementation of precision medicine in CVD. New developments in single-photon emission computed tomography (SPECT) and positron emission tomography (PET) systems, combined with rapid innovations in promising and specific radiopharmaceuticals, provide an impressive improvement of diagnostic accuracy and therapy evaluation. This may result in improved health outcomes in CVD patients, thereby reducing societal impact. Furthermore, recent technical advances have led to new possibilities for accurate image quantification, dynamic imaging, and quantification of radiotracer kinetics. This potentially allows for better evaluation of disease activity over time and treatment response monitoring. However, the clinical implementation of these new methods has been slow. This review describes the recent advances in molecular imaging and the clinical value of quantitative PET and SPECT in various fields in cardiovascular molecular imaging, such as atherosclerosis, myocardial perfusion and ischemia, infiltrative cardiomyopathies, systemic vascular diseases, and infectious cardiovascular diseases. Moreover, the challenges that need to be overcome to achieve clinical translation are addressed, and future directions are provided.

13 November 2024 in Seminars in Nuclear Medicine
Verified
Journal Article
Open access
TMT. Samara Martinez-Lucio
T. Samara Martinez-Lucio
OMOscar Isaac Mendoza-Ibañez
Oscar Isaac Mendoza-Ibañez
WLWanling Liu
Wanling Liu
SMSamaneh Mostafapour
Samaneh Mostafapour
ZLZekai Li
Zekai Li
Riemer H.J.A. SlartRiemer H.J.A. Slart
Riemer H.J.A. Slart
Positron emission tomography / computed tomography (PET/CT) plays a pivotal role in the assessment of cardiovascular diseases (CVD), particularly in the context of ischemic heart disease. Nevertheless, its application in other forms of CVD, such as infiltrative, infectious, or inflammatory conditions, remains limited. Recently, PET/CT systems with an extended axial field of view (LAFOV) have been developed, offering greater anatomical coverage and significantly enhanced PET sensitivity. These advancements enable head-to-pelvis imaging with a single bed position, and in systems with an axial field of view (FOV) of approximately 2 meters, even total body (TB) imaging is feasible in a single scan session. The application of LAFOV PET/CT in CVD presents a promising opportunity to improve systemic cardiovascular assessments and address the limitations inherent to conventional short axial field of view (SAFOV) devices. However, several technical challenges, including procedural considerations for LAFOV systems in CVD, complexities in data processing, arterial input function extraction, and artefact management, have not been fully explored. This review aims to discuss the technical aspects of LAFOV PET/CT in relation to CVD by highlighting key opportunities and challenges and examining the impact of these factors on the evaluation of most relevant CVD.

4 March 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
OMOscar Isaac Mendoza-Ibañez
Oscar Isaac Mendoza-Ibañez
Riemer H.J.A. SlartRiemer H.J.A. Slart
Riemer H.J.A. Slart
EAErick Alexanderson-Rosas
Erick Alexanderson-Rosas
TMT. Samara Martinez-Lucio
T. Samara Martinez-Lucio
FZFriso M. van der Zant
Friso M. van der Zant
SLSergiy Lazarenko
Sergiy Lazarenko
Background: The choice of software package (SP) for image processing affects the reproducibility of myocardial blood flow (MBF) values in [13N]NH3 PET/CT scans. However, the impact of motion correction (MC) tools—integrated software motion correction (ISMC) or data-driven motion correction (DDMC)—on the inter-software reproducibility of MBF has not been studied. This research aims to evaluate reproducibility among three commonly used SPs and the role of MC. Methods: Thirty-six PET/CT studies from patients without myocardial ischemia or infarction were processed using QPET, Corridor-4DM (4DM), and syngo.MBF (syngo). MBF and coronary flow reserve (CFR) values were obtained without motion correction (NMC) and with ISMC and DDMC. Intraclass correlation coefficients (ICC) and Bland-Altman (BA) plots were used to analyze agreement. Results: Good or excellent reproducibility (ICC ≥ 0.77) was found for rest-MBF values, regardless of the SPs or use of MC. In contrast, stress-MBF and CFR values presented mostly a moderate agreement when NMC was used. The RCA territory consistently had the lowest agreement in stress-MBF and CFR in the comparisons involving QPET. The use of MC, particularly DDMC, enhanced the reproducibility of most of the stress-MBF and CFR values by improving ICCs and reducing bias and limits of agreement (LoA) in BA analysis. Conclusions: MBF quantification agreement between SPs is strong for rest-MBF values but suboptimal for stress-MBF and CFR values. MC tools, especially DDMC, are recommended for improving reproducibility in stress-MBF assessments, although differences in SP reproducibility up to 0.77 mL/g/min in global stress-MBF and up to 0.88 in global CFR remain despite the use of MC.

18 July 2025 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
TMT. Samara Martinez-Lucio
T. Samara Martinez-Lucio
SLSergiy V. Lazarenko
Sergiy V. Lazarenko
OMOscar Isaac Mendoza-Ibañez
Oscar Isaac Mendoza-Ibañez
RKRemco J. J. Knol
Remco J. J. Knol
AMAndrea G. Monroy-Gonzalez
Andrea G. Monroy-Gonzalez
RSRiemer H. J. A. Slart
Riemer H. J. A. Slart
Transient ischemic dilation has been conventionally calculated from the static images, and has been scarcely investigated by PET/CT. Therefore, we aim to evaluate the impact of the quantification method and software package on TID ratio by [13N]NH3 PET/CT; moreover, perform a comprehensive evaluation of TID in normal-perfusion and myocardial ischemic patients. Retrospective analysis of 125 [13N]NH3 PET/CT scans with Corridor 4DM and QPS/QGS software packages. TID ratio was calculated from static and gated left ventricular volumes. Comparisons were performed according to ischemic extent and software package. Correlations with LV function and perfusion variables were assessed. TID ratios were significantly higher in ischemic patients (p < 0.05), except for TID gated EDV from QPS/QGS. TID static and TID gated ESV from QPS/QGS were different between the very severe ischemic subgroup and the group without ischemia (p = 0.0003). TID gated ESV from Corridor 4DM was higher in moderate, severe, and very severe ischemic subgroups than the normal-perfusion group (p = 0.02). TID gated ESV presented strong inverse correlations with myocardial flow reserve (MFR) in the very severe ischemic subgroup with Corridor 4DM, and with ejection fraction (LVEF) reserve, independent of the software and percentage of ischemic extent. Upper limits for TID static, ESV, and EDV with QPS/QGS were 1.17, 1.57, and 1.3, respectively. TID static, ESV, and EDV upper limits with Corridor4DM were 1.25, 1.29, and 1.21, respectively. TID ratios from [13N]NH3 PET/CT are higher in ischemic than in normal-perfusion patients and related to ischemic extent. TID ratios correlated strongly with LVEF reserve and MFR. The processing software and metric quantification method may influence the TID ratio.

26 January 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
OMOscar Isaac Mendoza-Ibañez
Oscar Isaac Mendoza-Ibañez
Riemer H.J.A. SlartRiemer H.J.A. Slart
Riemer H.J.A. Slart
CHCharles Hayden
Charles Hayden
TMT. Samara Martinez-Lucio
T. Samara Martinez-Lucio
FZFriso M. van der Zant
Friso M. van der Zant
SLSergiy Lazarenko
Sergiy Lazarenko
Background: Motion is a long-standing problem in cardiac PET/CT. An automated data-driven motion correction (DDMC) algorithm for within-reconstruction motion correction (MC) has been developed and validated in static images from [13N]NH3 and 82Rb PET/CT. This study aims to validate DDMC in dynamic [13N]NH3 PET/CT, and to explore the added value of DDMC in the evaluation of myocardial motion. Methods: Thirty-six PET/CT studies from normal patients and forty-three scans from patients with myocardial ischemia were processed using QPET software without MC (NMC), using manual in-software MC (ISMC), and DDMC. Differences in the mean values of rest-, stress-MBF, and CFR; and differences in effect size related to the use and type of MC method were explored. Moreover, motion vectors provided by DDMC were analyzed to evaluate differences in myocardial motion between scan phases and axes, and to elucidate changes in MBF quantification in relation to the motion extent. Results: In both subgroups, repeated measures ANOVA showed that the use of MC significantly increased regional and global stress-MBF and CFR values (p < 0.05), regardless of the MC method. Paired t-test analysis demonstrated a comparable ES between MC tools, despite minor differences in Cx, RCA and global rest-MBF values. High-intensity motion (>6 mm) proved to be present almost exclusively in the Z (cranio-caudal) direction. In the same axis, motion was significantly higher during stress than rest, regardless of patients’ subgroup. Finally, the Jonckheere trend test showed a significant trend caused by motion in s-MBF values, in which lower stress-MBF values were observed in response to motion extent increments. Conclusions: DDMC is feasible to perform in [13N]NH3 dynamic acquisitions and provides similar MBF/CFR values than manual ISMC. The use of DDMC reduces post-processing times and observer variability, and allows a more extensive evaluation of motion. MC is highly recommended when using QPET, as motion in the Z-axis during stress scans negatively impacts stress-MBF quantification.

1 May 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
TMT. Samara Martinez-Lucio
T. Samara Martinez-Lucio
RKRemco Knol
Remco Knol
OMOscar Isaac Mendoza-Ibañez
Oscar Isaac Mendoza-Ibañez
LWLars van Wunnik
Lars van Wunnik
FZFriso M. van der Zant
Friso M. van der Zant
SLSergiy Lazarenko
Sergiy Lazarenko
Background/Objectives: Gated cardiac positron emission tomography (PET) synchronizes PET data to the cardiac cycle based on an electrocardiogram (ECG) signal, providing left ventricular (LV) functional and geometrical parameters. Nevertheless, image artifacts, due to cardiac-, breathing-, and/or patient-motion occurring during image acquisition, undermine the reliability and clinical utility of these parameters. This study aims to elucidate the effect of two motion correction (MC) tools, CardioFreeze (CF) and a data-driven motion correction (DDMC) prototype, on LV functional and geometrical parameters. Methods: ECG-gated rest/stress [13N]NH3 PET/CT scans from forty patients with myocardial ischemia and thirty-nine patients with normal myocardial perfusion were included. The following four reconstructions were performed for each patient scan: without motion correction (NMC), with CF, DDMC, and DDMC & CF. Images were processed with Cedars-Sinai QPET software. Results: End-diastolic volume (EDV) in rest and stress increased significantly using DDMC. End-systolic volume (ESV) increased significantly, while LV ejection fraction (LVEF) decreased significantly using any MC tool, regardless of the phase. Shape index end-systole (SI ES) and shape-index end-diastole (SI ED) increased significantly when using MC, except for SI ED in rest, where DDMC did not cause any difference. Eccentricity index end-systole (ECC ES) in rest and stress increased significantly in patients with normal myocardial perfusion, while it did not differ in ischemic patients after applying MC. Conclusions: MC tools significantly increase ESV values and decrease EF values. The highest effect is observed with the combined use of DDMC & CF. Image quality is greatly improved when using MC, regardless of the method, particularly in patients with the highest myocardial displacement.