Cynthia Chuang

Prof. Cynthia Chuang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2020 in Cureus
Verified
Journal Article
Open access
PDF file
PRPantaleo Romanelli
Pantaleo Romanelli
CCCynthia Chuang
Cynthia Chuang
AMAntonio Meola
Antonio Meola
RBRadhika M. Bodduluri
Radhika M. Bodduluri
JAJohn Adler
John Adler
The treatment of trigeminal neuralgia (TN) is one of the most demanding of all radiosurgery procedures, requiring accurate delivery and sharp dose fall off. ZAP-X®, a new, innovative frameless radiosurgical device, maybe an attractive platform for the treatment of TN and other functional brain disorders. Here, we compared the dosimetry of ZAP-X plans for a single patient to that generated by a well-established dedicated radiosurgery device, the CyberKnife. Radiosurgery plans that delineated the cranial nerve from a single patient’s fused computed tomography and magnetic resonance imaging (CT-MR) data set were planned on both the ZAP-X and CyberKnife, with the latter serving as a validated benchmark. The same target and treatment planning constraints were applied. Plans were evaluated by a physician with experience treating TN and a medical physicist. The ZAP-X treatment plan used two isocenters delivered through 4-mm collimators based on a non-isocentric plan that delivered 29,441 MU through 81 beams. The CyberKnife plans used a 5-mm collimator for a non-isocentric plan that delivered 17,880 MU through 88 beams. Based on visual inspection, the isodose volumes covered by ZAP-X and CyberKnife were similar at the prescription isodose (70% and 80%, respectively, with a maximum dose (Dmax) of 7500 cGy. The conformality index was better for the CyberKnife as compared to ZAP-X. However, the irradiated volumes were smaller at the 50%, 20%, and 10% isodoses for ZAP-X (0.12 cc, 0.57 cc, and 1.69 for ZAP-X; 0.18 cc, 0.91 cc, and 3.41 cc for CyberKnife). In particular, the 20% and 10% isodose volumes were much smaller for ZAP-X, especially on the axial and sagittal planes. ZAP-X treatment planning for TN compares favorably with equivalent planning on CyberKnife. The brain volumes containing the 20% and 10% isodoses are smaller using ZAP-X, thus relatively sparing critical structures close to the target, including the Gasserian ganglion and brainstem. This feature could be of clinical relevance by potentially reducing treatment-related complications.

3 May 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
MKMatthew Jinsoo Kim
Matthew Jinsoo Kim
JWJen-Yeu Wang
Jen-Yeu Wang
WLWeiguo Lu
Weiguo Lu
HJHao Jiang
Hao Jiang
SSStrahinja Stojadinovic
Strahinja Stojadinovic
XGXuejun Gu
Xuejun Gu
Detection and segmentation of brain metastases (BMs) play a pivotal role in diagnosis, treatment planning, and follow-up evaluations for effective BM management. Given the rising prevalence of BM cases and its predominantly multiple onsets, automated segmentation is becoming necessary in stereotactic radiosurgery. It not only alleviates the clinician’s manual workload and improves clinical workflow efficiency but also ensures treatment safety, ultimately improving patient care. Recent strides in machine learning, particularly in deep learning (DL), have revolutionized medical image segmentation, achieving state-of-the-art results. This review aims to analyze auto-segmentation strategies, characterize the utilized data, and assess the performance of cutting-edge BM segmentation methodologies. Additionally, we delve into the challenges confronting BM segmentation and share insights gleaned from our algorithmic and clinical implementation experiences.

14 February 2025 in Brain Sciences
Verified
Journal Article
Open access
PDF file
FLFred Lam
Fred Lam
SGSantosh Guru
Santosh Guru
DADeyaldeen AbuReesh
Deyaldeen AbuReesh
YHYusuke S. Hori
Yusuke S. Hori
CCCynthia Chuang
Cynthia Chuang
SCSteven D Chang
Steven D Chang
Current standard of care treatment for patients with spine tumors includes multidisciplinary approaches, including the following: (1) surgical tumor debulking, epidural spinal cord decompression, and spine stabilization techniques; (2) systemic chemo/targeted therapies; (3) radiation therapy; and (4) surveillance imaging for local disease control and recurrence. Titanium pedicle screw and rod fixation have become commonplace in the spine surgeon’s armamentarium for the stabilization of the spine following tumor resection and separation surgery. However, the high degree of imaging artifacts seen with titanium implants on postoperative CT and MRI scans can significantly hinder the accurate delineation of vertebral anatomy and adjacent neurovascular structures to allow for the safe and effective planning of downstream radiation therapies and detection of disease recurrence. Carbon fiber-reinforced polyetheretherketone (CFR-PEEK) spine implants have emerged as a promising alternative to titanium due to the lack of artifact signals on CT and MRI, allowing for more accurate and safe postoperative radiation planning. In this article, we review the tenants of the surgical and radiation management of spine tumors and discuss the safety, efficacy, and current limitations of CFR-PEEK spine implants in the multidisciplinary management of spine oncology patients.

27 July 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
WZWei Zhao
Wei Zhao
YYYong Yang
Yong Yang
LXLei Xing
Lei Xing
CCCynthia Chuang
Cynthia Chuang
ESEmil Schüler
Emil Schüler
Small field dosimetry is significantly different from the dosimetry of broad beams due to loss of electron side scatter equilibrium, source occlusion, and effects related to the choice of detector. However, use of small fields is increasing with the increase in indications for intensity-modulated radiation therapy and stereotactic body radiation therapy, and thus the need for accurate dosimetry is ever more important. Here we propose to leverage machine learning (ML) strategies to reduce the uncertainties and increase the accuracy in determining small field output factors (OFs). Linac OFs from a Varian TrueBeam STx were calculated either by the treatment planning system (TPS) or measured with a W1 scintillator detector at various multi-leaf collimator (MLC) positions, jaw positions, and with and without contribution from leaf-end transmission. The fields were defined by the MLCs with the jaws at various positions. Field sizes between 5 and 100 mm were evaluated. Separate ML regression models were generated based on the TPS calculated or the measured datasets. Accurate predictions of small field OFs at different field sizes (FSs) were achieved independent of jaw and MLC position. A mean and maximum % relative error of 0.38 ± 0.39% and 3.62%, respectively, for the best-performing models based on the measured datasets were found. The prediction accuracy was independent of contribution from leaf-end transmission. Several ML models for predicting small field OFs were generated, validated, and tested. Incorporating these models into the dose calculation workflow could greatly increase the accuracy and robustness of dose calculations for any radiotherapy delivery technique that relies heavily on small fields.

31 August 2023
Verified
Book Chapter
Closed access
PDF file
APAngélica Pérez-Andújar
Angélica Pérez-Andújar
MDMartina Descovich
Martina Descovich
CCCynthia Chuang
Cynthia Chuang