Power systems are making a transition from purely technical, centrally planned systems to market based, decentralized systems. The need for balancing power and frequency control reserves are increasing, partially due to variable renewable production, which gives an opportunity for new incomes but also a challenge in terms of changed modes of operation with risk for reduced life time for controllable power plants. This paper investigates how the allocation of a sold volume of frequency control reserves within a large hydropower production fleet can affect the costs of providing primary and secondary reserves, in terms of its impact on wear and fatigue, production losses and the quality of the delivered frequency control. The results show that for primary control, low static gain in the governors results in poor quality and a large amount of load cycles of the units. High static gain, on the other hand, increases the production losses. The control work of the fleet can be reduced by using a proper balance of primary and secondary control gain on each unit, although the intuitive results from linear models exaggerate this effect. Automatic secondary control improves the system frequency quality but also increases the wear.
17 April 2018 in IEEE Transactions on Industrial Electronics
Unbalanced magnetic pull (UMP) is typically caused by rotor or stator shape defects, electrical short circuits, eccentric rotor/stator bores as well as unreasonable pole-slot combinations. It leads to vibration and increases noise and energy losses of the machine. By actively controlling the magnetic fields and forces that arise between the rotor and stator by regulating the rotor field current of separated pole groups, it is possible to cancel it. In this contribution, we measured and calculated the currents induced in the damper bars for a synchronous machine test rig under 20% static eccentricity with and without active compensation of UMP. This was utilized to validate our finite element calculations. Afterwards, we performed loss calculations for a 74 MVA synchronous generator with and without stator parallel circuits. We found that, with active compensation of UMP for an eccentric machine, the damper bar currents and stator parallel circuit circulating currents can be eliminated and the electromagnetic efficiency of the machine which has a static eccentricity fault increases.
29 August 2017 in IEEE Transactions on Energy Conversion
The static exciter is dominating among large grid-connected generators due to the weak dynamic performance of conventional brushless exciters. In this contribution, a six-phase double-star outer pole permanent magnet rotating brushless exciter is evaluated with different active rectification topologies. Both thyristor-based and chopper-based topologies are considered. A high speed response brushless excitation system is obtained by replacing the conventional rotating diode bridge rectifier with the proposed active rectification topologies on the shaft. The given two-stage system generates its own excitation power directly from the shaft, contrary to static exciters. The selection of an appropriate rectification topology could minimize the rotor armature phase currents for a given generator field current. The objective is a high-power factor and a high utilization of the exciter machine. An optimal rectification topology makes higher ceiling currents was possible, improving the transient behavior of the synchronous generator. In this paper, we show that six-phase topologies add complexity, but improve exciter redundancy, increase the available ceiling voltage, and reduce the steady-state torque ripple. Experimental results are given for validating the models implemented for the analysis.
24 April 2023 in IEEE Transactions on Energy Conversion
The upcoming modifications to the criteria for providing Frequency Containment Reserves (FCR) in the Nordic synchronous area present severe challenges for some hydropower units. By quantifying the difference between the required FCR power response and the actual response provided by the unit, an additional power response from an energy storage system can be specified to augment the hydropower unit, thus securing its participation in FCR in the future. A practical method to control the storage system, by applying a band-pass filter on the negative frequency deviation, is presented in this paper. The method is verified using a set of field measurements from Swedish hydropower units currently providing FCR. It is found that all tested units are able to satisfy the upcoming criteria with the specified storage systems. The optimality of the method is discussed by comparing the storage system power and energy ratings to the theoretical minimum. Obtained power ratings between 3% and 24% of the FCR power, combined with a short storage system duration of up to 2.5 minutes, indicate that the method presents a possible application for high-power and low-energy storage technologies.
10 August 2020 in IEEE Transactions on Energy Conversion
A magnetization system with active compensation of unbalanced magnetic pull for synchronous machines with rotating exciters is demonstrated. The system used switched power electronics and a digital control system to control the currents in four rotor pole groups, each consisting of 3 poles. It was mounted on the shaft of a synchronous machine, providing an interface between a permanent magnet outer-pole brushless exciter and the segmented field winding. Measurements of magnetic flux density on each pole face and current control made it possible to control the airgap magnetic flux density to balance the machine magnetically, thus removing flux density space harmonics in the airgap and also the unbalanced magnetic pull. The construction of the system is presented along with results from experiments and simulations. Tests were performed with the stator winding both in series and with two parallel circuits. Approximately $\mathbf {80\%}$ reduction of static forces and $\mathbf {60\%}$ reduction of dynamic forces between the stator and rotor were observed when the system was running.