Meimei Zeng

Ms. Meimei Zeng

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
XHXuliang He
Xuliang He
MZMeimei Zeng
Meimei Zeng
WBWentao Bai
Wentao Bai
ZTZiyan Tang
Ziyan Tang
JDJianhua Ding
Jianhua Ding
ZHU CHENZHU CHEN
ZHU CHEN
Pseudomonas aeruginosa (PA) is a significant pathogen of clinical concern that is frequently associated with multidrug resistance, leading to respiratory tract, wound, and hospital-acquired infections. To enable rapid and accurate detection, we developed a fluorescence-based loop-mediated isothermal amplification (LAMP) method, targeting the PA-specific ecfX gene. Among ten primer sets designed, the optimal set (EC2) was identified, and reaction conditions were optimized (Bst polymerase 320 U/mL, Mg2+ 8 mM, dNTP 1.4 mM, inner/outer primer ratio 1:8, 64 °C, 20 min). The assay demonstrated a detection limit that was comparable to a real-time polymerase chain reaction and immunochromatographic assays, but with a markedly reduced turnaround time. No cross-reactivity was observed with non-PA pathogens, and reproducibility tests confirmed high stability. In addition, the reliability of the results was further verified using 60 standard bacterial strains, and the feasibility of the assay was validated with 2 real soil samples and 1 water sample. This LAMP method offers a simple, rapid, and sensitive tool for on-site detection of PA, with potential applications in clinical diagnostics and public health surveillance.

3 March 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
MZMeimei Zeng
Meimei Zeng
XWXinru Wang
Xinru Wang
ZTzi feng Tan
zi feng Tan
WGWenyan Guo
Wenyan Guo
YDYan Deng
Yan Deng
ZHU CHENZHU CHEN
ZHU CHEN
The accurate detection of Mycobacterium tuberculosis (MTB) is a pressing challenge in the precise prevention and control of tuberculosis. Currently, the efficiency and accuracy of drug resistance detection for MTB are low, and cross-contamination is common, making it inadequate for clinical needs. This study developed a rapid nucleic acid detection method for MTB based on scattering loop-mediated isothermal amplification (LAMP). Specific primers for the MTB-specific gene (Ag85B) were designed, and the LAMP reaction system was optimized using a self-developed scattering LAMP turbidimeter. Experimental results showed that the optimal reaction system included 1.5 µL of 100 mmol/L magnesium ions, 3.5 µL of 10 mmol/L dNTPs, 6 µL of 1.6 mol/L betaine, and a reaction temperature of 65 °C. The minimum detection limit was 12.40 ng/L, with the fastest detection time being approximately 10 min. The reaction exhibited good specificity, with no amplification bands for other pathogens. Twenty culture-positive samples and twenty culture-negative samples were tested in parallel; the accuracy of the positive group was 100%, the detection time was (24.9 ± 13 min), and there was no negative detection. This method features high detection efficiency, low cost, high accuracy, and effectively reduces cross-contamination, providing a new technology for the rapid clinical detection of MTB.