To evaluate the intratubular penetration depth of ultrasound-activated bioceramic sealant cements into root dentin, specifically at the dentin-cement interface. This in vitro experimental study was conducted with samples that were randomly divided based on the type of sealer used and whether ultrasound activation was applied prior to obturation. This resulted in four experimental groups (n=40). Groups A1 and B1 utilized the Eighteeth Ultra X ultrasonic activator with a blue tip #20 featuring a 2% taper at low power for activation, while groups A2 and B2 did not employ any form of activation. The symbol (+) denotes groups with ultrasonic activation, while (-) represents groups without ultrasonic activation. In the middle third, it was observed that BioC Sealer (+) had a mean sealing value of 0.66±0.17, while MTA Fillapex (+) showed a mean value of 0.38±0.07. It was found that BioC Sealer (-) had a mean sealing value of 0.24±0.04 in the middle third, while MTA Fillapex (-) showed a mean value of 0.16±0.04. These differences were not statistically significant (p=0.569). In the apical third, the BioC Sealer (-) presented a mean sealing value of 0.44±0.17, while the MTA Fillapex (-) obtained a mean value of 0.30±0.04. However, this difference did not reach statistical significance (p=0.0745), suggesting that both materials can provide a similar seal in the apical third. The results suggest that both BioC Sealer and MTA Fillapex provide a comparable seal in the middle and apical thirds of the root canal system, however, this was not statistically significant. This indicates their potential efficacy in both endodontic sealing procedures.
Objetivo: Evaluar el efecto antimicótico in vitro de aceite esencial de Origanum vulgare, sobre cepa de Candida albicans ATCC 10231 Material y método: Se efectuó la selección de cuatro de diferentes geotipos de orégano, se obtuvo los aceites esenciales mediante proceso de destilación por arrastre con vapor de agua; se determinó su composición química cuantitativa por Cromatografía de Gases, Espectrometría de Masas (CG/EM). Se evaluó in vitro la actividad antimicótica de los aceites esenciales a través de pruebas de sensibilidad con el método de difusión por discos en cultivo de agar frente a C. albicans. Resultados: Los resultados mostraron alta actividad antimicótica de todas los aceites a partir de las concentración de 12,5 %. Conclusiones: Los aceites esenciales del Origanum vulgare de los diversos geotipos presentan diferencias en sus efectos antimicóticos. El aceite esencial de Origanum vulgare puede ser es una alternativa farmacológica para el tratamiento de infecciones micóticas en boca.
Objetivo: Determinar y analizar la capacidad de humectancia de soluciones irrigantes usadas en el tratamiento de conductos radiculares sobre la superficie dentinaria de dientes de bovino. Materiales y método: Estudio experimental in vitro. Se preparó 60 bloques de acrílicoautocurado de 40 mm x 30 mm x 8 mm donde una superficie expone tejido dentinario de diente de bovino. Los irrigantes de prueba fueron: solución de hipoclorito de sodio al 5,25%, gluconato de clorhexidina al 0.12%, suero fisiologico y agua de cal. En la superficie de dentina se depositó una gota calibrada de las soluciones irrigantes, estas gotas sésiles en contacto con dentina mostraron muchas formas las cuales fueron foto-grafiadas para posteriormente superponerle el trazo de una tangente desde el punto de contacto y sobre el ecuador del arco establecido, el ángulo resultante fue medido con un transportador estableciendo el ángulo de contacto. Resultados: Gluconato de Clorhexidina al 0,12 %, establecía un ángulo de con-tacto promedio de 41.33º, seguidos por el agua de cal: 43.23º, hipoclorito de sodio al 5,25%: 61.17º y la solución salina al 9/1000 con 61.43º. Conclusiones: Se concluye que la clorhexidina y el agua de cal son los líquidos con mayor capacidad de humectancia sobre dentina de diente de bobino. Resultado no esperado pues por las características moleculares se creía que el hipoclorito de sodio tendría una mejor capacidad de humectancia.
Objectives: This study evaluated the dental and alveolar bone stress distribution of a mandibular Kennedy Class I restored with a conventional removable partial denture (CRPD) compared with bilateral implant-assisted removable partial denture (IARPD) through the application of finite element analysis (FEA). Methods: Kennedy Class I plaster models were made, including teeth from lower left first premolar and lower right canine. The models were scanned, resin-based replicated and digitized. Using Solidworks software, internal hexagonal implants (10 mm x 4 mm) were virtually placed at the level of the first molars. Each model was grouped into a unit and a load of 200 N was applied, simulating masticatory forces. Von Mises stress distributions were calculated by FEA for the vertical, diagonal and combined forces. Results: In IARPD, the stress generated in the alveolar bone by the vertical (4.2 Mpa), diagonal (12.2 MPa) and combined forces (12.3 MPa) was lower than CRPD (7 MPa, 26.3 MPa and 32 MPa, respectively). Similarly, at the lower central incisor level, the IARPD generated less stress than the CRPD due to the action of the vertical, diagonal and combined forces. Conclusions:Our preliminary data suggest that bilateral implant placement may result in less stress on bone and teeth during the rehabilitation with an IARPD Kennedy Class I, with different orientations of the forces applied.
Objectives: This study evaluated the dental and alveolar bone stress distribution of a mandibular Kennedy Class I restored with a bilateral implant-assisted removable partial denture (IARPD) compared with a conventional removable partial denture (CRPD) through the application of finite element analysis (FEA). Methods: Kennedy Class I plaster models were made, including teeth from the lower left first premolar and lower right canine. The models were scanned, resin-based replicated and digitized. Using Solidworks software, internal hexagonal implants (10 mm × 4 mm) were virtually placed at the level of the first molars. Each model was grouped into a unit, and a load of 200 N was applied, simulating masticatory forces. Von Mises stress distributions were calculated via FEA for the vertical, diagonal and combined forces. Results: In the IARPD, the stress generated in the alveolar bone by the vertical (4.2 Mpa), diagonal (12.2 MPa) and combined forces (12.3 MPa) was lower than that of the CRPD (7 MPa, 26.3 MPa and 32 MPa, respectively). Similarly, at the lower central incisor, the IARPD generated less stress than the CRPD due to the action of the vertical, diagonal and combined forces. Conclusions: Our preliminary data suggest that bilateral implant placement may result in less stress on bone and teeth during rehabilitation with a Kennedy Class I IARPD, with different orientations of the forces applied.