To evaluate the intratubular penetration depth of ultrasound-activated bioceramic sealant cements into root dentin, specifically at the dentin-cement interface. This in vitro experimental study was conducted with samples that were randomly divided based on the type of sealer used and whether ultrasound activation was applied prior to obturation. This resulted in four experimental groups (n=40). Groups A1 and B1 utilized the Eighteeth Ultra X ultrasonic activator with a blue tip #20 featuring a 2% taper at low power for activation, while groups A2 and B2 did not employ any form of activation. The symbol (+) denotes groups with ultrasonic activation, while (-) represents groups without ultrasonic activation. In the middle third, it was observed that BioC Sealer (+) had a mean sealing value of 0.66±0.17, while MTA Fillapex (+) showed a mean value of 0.38±0.07. It was found that BioC Sealer (-) had a mean sealing value of 0.24±0.04 in the middle third, while MTA Fillapex (-) showed a mean value of 0.16±0.04. These differences were not statistically significant (p=0.569). In the apical third, the BioC Sealer (-) presented a mean sealing value of 0.44±0.17, while the MTA Fillapex (-) obtained a mean value of 0.30±0.04. However, this difference did not reach statistical significance (p=0.0745), suggesting that both materials can provide a similar seal in the apical third. The results suggest that both BioC Sealer and MTA Fillapex provide a comparable seal in the middle and apical thirds of the root canal system, however, this was not statistically significant. This indicates their potential efficacy in both endodontic sealing procedures.
Objectives: This study evaluated the dental and alveolar bone stress distribution of a mandibular Kennedy Class I restored with a conventional removable partial denture (CRPD) compared with bilateral implant-assisted removable partial denture (IARPD) through the application of finite element analysis (FEA). Methods: Kennedy Class I plaster models were made, including teeth from lower left first premolar and lower right canine. The models were scanned, resin-based replicated and digitized. Using Solidworks software, internal hexagonal implants (10 mm x 4 mm) were virtually placed at the level of the first molars. Each model was grouped into a unit and a load of 200 N was applied, simulating masticatory forces. Von Mises stress distributions were calculated by FEA for the vertical, diagonal and combined forces. Results: In IARPD, the stress generated in the alveolar bone by the vertical (4.2 Mpa), diagonal (12.2 MPa) and combined forces (12.3 MPa) was lower than CRPD (7 MPa, 26.3 MPa and 32 MPa, respectively). Similarly, at the lower central incisor level, the IARPD generated less stress than the CRPD due to the action of the vertical, diagonal and combined forces. Conclusions:Our preliminary data suggest that bilateral implant placement may result in less stress on bone and teeth during the rehabilitation with an IARPD Kennedy Class I, with different orientations of the forces applied.
Objectives: This study evaluated the dental and alveolar bone stress distribution of a mandibular Kennedy Class I restored with a bilateral implant-assisted removable partial denture (IARPD) compared with a conventional removable partial denture (CRPD) through the application of finite element analysis (FEA). Methods: Kennedy Class I plaster models were made, including teeth from the lower left first premolar and lower right canine. The models were scanned, resin-based replicated and digitized. Using Solidworks software, internal hexagonal implants (10 mm × 4 mm) were virtually placed at the level of the first molars. Each model was grouped into a unit, and a load of 200 N was applied, simulating masticatory forces. Von Mises stress distributions were calculated via FEA for the vertical, diagonal and combined forces. Results: In the IARPD, the stress generated in the alveolar bone by the vertical (4.2 Mpa), diagonal (12.2 MPa) and combined forces (12.3 MPa) was lower than that of the CRPD (7 MPa, 26.3 MPa and 32 MPa, respectively). Similarly, at the lower central incisor, the IARPD generated less stress than the CRPD due to the action of the vertical, diagonal and combined forces. Conclusions: Our preliminary data suggest that bilateral implant placement may result in less stress on bone and teeth during rehabilitation with a Kennedy Class I IARPD, with different orientations of the forces applied.
Objetivo: Determinar la actividad antibacteriana y efecto antibiofilm del extracto crudo etanólico de hojas de Camellia sinensis (té verde) sobre biofilm bi-especies. Materiales y métodos: Se utilizó un extracto etanólico crudo de té verde. Para la formación del biofilm se cultivaron cepas de Streptococcus mutans ATCC 25175 y Streptococcus gordonii ATCC 51656 bajo condiciones anaeróbicas. Se formaron 3 grupos: extracto de té verde, clorhexidina al 0,12% y dimetilsulfóxido como control negativo. El efecto antibacteriano se determinó mediante el método disco difusión en agar de Kirby-Bauer, midiendo el halo de inhibición formado en cada disco. Además, se identificó la concentración mínima inhibitoria con el método de microdilución. Se realizó el análisis de inmunofluorescencia para evaluar la viabilidad celular en el biofilm. Se utilizó la prueba t de Student para muestras independientes y comparar entre grupos. Resultados: Camellia sinensis generó un halo de inhibición para S. mutans de 17,4 ± 0,4 mm y para S. gordonii de 13,1 ± 0,3 mm, mientras que la clorhexidina produjo inhibición de 23,6 ± 0,3 mm y 13,2 ± 0,5 mm para S. mutans y S. gordonii, respectivamente. La concentración mínima inhibitoria fue de 3,12 mg/dl para el S. mutans y de 1,56 mg/dl para S. gordonii. El análisis de viabilidad celular con inmunofluorescencia mostró que, tras 48 horas de incubación, el extracto de Camellia sinensis redujo la viabilidad de las células del biofilm. Conclusiones: Pese a las limitaciones del estudio, se puede afirmar que el extracto de té verde presenta actividad antibacteriana frente al biofilm cariogénico multiespecies.