Zengzhou Yi

Dr. Zengzhou Yi


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2025 in Electronics
Verified
Journal Article
Open access
PDF file
ZYZengzhou Yi
Zengzhou Yi
YXYuWei Xu
YuWei Xu
JZJing-jin Zhang
Jing-jin Zhang
The microchannel plate (MCP) is susceptible to the adsorption of substantial amounts of gas during its fabrication process. To mitigate this, a uniform electron source is essential for effective electron scrubbing and gas removal. Thermionic emission, a method of electron generation, can be employed to create the electron source. In this study, a flat spiral filament was designed and simulated using the CST Studio Suite electron simulation software to assess the cleaning performance of the electron gun. The impact of variations in electron gun parameters on the uniformity of the electron beam and current density was systematically analysed. The simulation results show that, with filament, grid, focusing sleeve, and anode voltages set to 200 V, 500 V, 250 V, and 300 V, respectively, a uniform electron beam with a diameter exceeding 30 mm can be achieved. In order to obtain the current density (5~50 nA/mm2) required for the MCP, the temperature of the filament should be 1800–2000 K through theoretical calculation. These findings offer valuable insights for designing a more efficient electron gun for MCP scrubbing.

24 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
JZJing-jin Zhang
Jing-jin Zhang
YXYuWei Xu
YuWei Xu
ZYZengzhou Yi
Zengzhou Yi
QYQin-Lao Yang
Qin-Lao Yang
JHJun-Kun Huang
Jun-Kun Huang
FZFangke Zong
Fangke Zong
Streak cameras, known for their ultra-high spatiotemporal resolution, rely heavily on the spatial resolution capabilities of their core component, the streak tube, to ensure engineering stability. However, factors such as assembly inaccuracies and external magnetic fields, including geomagnetic interference, often cause deformation and shifts in the imaging plane. To enhance equipment stability and accelerate engineering advancements, a dual approach involving hardware improvements and computational imaging-based software corrections is essential. Future image reconstruction efforts in software require robust benchmarks; however, existing benchmarks are predominantly validated under idealized conditions, neglecting real-world interference factors. This study, grounded in electron optical imaging principles, experimentally confirms that the Lagrange–Helmholtz relationship remains valid within streak tube systems under geomagnetic field influences. These findings affirm that the imaging plane retains spatial resolution consistency despite such environmental disturbances. Consequently, the need for specific image orientations during reconstruction can be eliminated, enabling the development of more robust and efficient image reconstruction algorithms.