Sami Ramadan

Dr. Sami Ramadan


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2023 in ACS Nano
Verified
Journal Article
Open access
TYTianyi Yin
Tianyi Yin
Lizhou XuLizhou Xu
Lizhou Xu
BGBruno Gil
Bruno Gil
NMNabeel Merali
Nabeel Merali
MSMaria S. Sokolikova
Maria S. Sokolikova
NKNorbert Klein
Norbert Klein
Biosensors based on graphene field effect transistors (GFETs) have the potential to enable the development of point-of-care diagnostic tools for early stage disease detection. However, issues with reproducibility and manufacturing yields of graphene sensors, but also with Debye screening and unwanted detection of nonspecific species, have prevented the wider clinical use of graphene technology. Here, we demonstrate that our wafer-scalable GFETs array platform enables meaningful clinical results. As a case study of high clinical relevance, we demonstrate an accurate and robust portable GFET array biosensor platform for the detection of pancreatic ductal adenocarcinoma (PDAC) in patients' plasma through specific exosomes (GPC-1 expression) within 45 min. In order to facilitate reproducible detection in blood plasma, we optimized the analytical performance of GFET biosensors via the application of an internal control channel and the development of an optimized test protocol. Based on samples from 18 PDAC patients and 8 healthy controls, the GFET biosensor arrays could accurately discriminate between the two groups while being able to detect early cancer stages including stages 1 and 2. Furthermore, we confirmed the higher expression of GPC-1 and found that the concentration in PDAC plasma was on average more than 1 order of magnitude higher than in healthy samples. We found that these characteristics of GPC-1 cancerous exosomes are responsible for an increase in the number of target exosomes on the surface of graphene, leading to an improved signal response of the GFET biosensors. This GFET biosensor platform holds great promise for the development of an accurate tool for the rapid diagnosis of pancreatic cancer.

9 February 2021 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
SRSami Ramadan
Sami Ramadan
RLRichard Lobo
Richard Lobo
YZYuanzhou Zhang
Yuanzhou Zhang
LXLizhou Xu
Lizhou Xu
OSOlena Shaforost
Olena Shaforost
NKNorbert Klein
Norbert Klein

13 May 2024 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
RCRongwei Cui
Rongwei Cui
HTHuijing Tang
Huijing Tang
QHQing Huang
Qing Huang
TYTingsong Ye
Tingsong Ye
JCJiyang Chen
Jiyang Chen
DLDanyang Li
Danyang Li

15 December 2021 in ACS Sensors
Verified
Journal Article
Open access
LXLizhou Xu
Lizhou Xu
SRSami Ramadan
Sami Ramadan
OAOluwatomi E. Akingbade
Oluwatomi E. Akingbade
YZYuanzhou Zhang
Yuanzhou Zhang
SASarah Alodan
Sarah Alodan
Bing LiBing Li
Bing Li
Glial fibrillary acidic protein (GFAP) is a discriminative blood biomarker for many neurological diseases, such as traumatic brain injury. Detection of GFAP in buffer solutions using biosensors has been demonstrated, but accurate quantification of GFAP in patient samples has not been reported, yet in urgent need. Herein, we demonstrate a robust on-chip graphene field-effect transistor (GFET) biosensing method for sensitive and ultrafast detection of GFAP in patient plasma. Patients with moderate–severe traumatic brain injuries, defined by the Mayo classification, are recruited to provide plasma samples. The binding of target GFAP with the specific antibodies that are conjugated on a monolayer GFET device triggers the shift of its Dirac point, and this signal change is correlated with the GFAP concentration in the patient plasma. The limit of detection (LOD) values of 20 fg/mL (400 aM) in buffer solution and 231 fg/mL (4 fM) in patient plasma have been achieved using this approach. In parallel, for the first time, we compare our results to the state-of-the-art single-molecule array (Simoa) technology and the classic enzyme-linked immunosorbent assay (ELISA) for reference. The GFET biosensor shows competitive LOD to Simoa (1.18 pg/mL) and faster sample-to-result time (<15 min), and also it is cheaper and more user-friendly. In comparison to ELISA, GFET offers advantages of total detection time, detection sensitivity, and simplicity. This GFET biosensing platform holds high promise for the point-of-care diagnosis and monitoring of traumatic brain injury in GP surgeries and patient homes.

19 December 2023 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
WHWenyi Huang
Wenyi Huang
QYQutong Yang
Qutong Yang
JLJiahui Liao
Jiahui Liao
SRSami Ramadan
Sami Ramadan
XFXiaoming Fan
Xiaoming Fan
CFChen Fu
Chen Fu

18 December 2025 in ACS Nano
Verified
Journal Article
Closed access
TYTianyi Yin
Tianyi Yin
JSJiapeng Song
Jiapeng Song
XHXingkai Hao
Xingkai Hao
YWYuhao Wen
Yuhao Wen
PYPeiji Yang
Peiji Yang
NKNorbert Klein
Norbert Klein