Emma Donnelly

Ms. Emma Donnelly

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2022 in Orthopaedic Journal of Sports Medicine
Verified
Journal Article
Open access
EDEmma Donnelly
Emma Donnelly
SVSamira Vakili
Samira Vakili
AGAlan Getgood
Alan Getgood
RWRyan Willing
Ryan Willing
RDRyan M. Degen
Ryan M. Degen
Background: It remains unclear if capsular management contributes to iatrogenic instability (microinstability) after hip arthroscopy. Purpose: To evaluate changes in torque, stiffness, and femoral head displacement after capsulotomy and repair in a cadaveric model. Study Design: Controlled laboratory study. Methods: A biomechanical analysis was performed using 10 cadaveric hip specimens. Each specimen was tested under the following conditions: (1) intact, (2) portals, (3) interportal capsulotomy (IPC), (4) IPC repair, (5) T-capsulotomy (T-cap), (6) partial T-cap repair, and (7) T-cap repair. Each capsular state was tested in neutral (0°) and then 30°, 60°, and 90° of flexion, with forces applied to achieve the displacement-controlled baseline limit of external rotation (ER), internal rotation (IR), abduction, and adduction. The resultant end-range torques and displacement were recorded. Results: For ER, capsulotomies significantly reduced torque and stiffness at 0°, 30°, and 60° and reduced stiffness at 90°; capsular repairs failed to restore torque and stiffness at 0°; and IPC repair failed to restore stiffness at 30° ( P < .05 for all). For IR, capsulotomies significantly reduced torque and stiffness at 0°, 30°, and 60° and reduced stiffness at 90°; and capsular repairs failed to restore torque or stiffness at 0°, 30°, and 60° and failed to restore stiffness at 90° ( P < .05 for all). For abduction, IPC significantly decreased torque at 60° and 90° and decreased stiffness at all positions; T-cap reduced torque and stiffness at all positions; IPC repair failed to restore stiffness at 0° and 90°; and T-cap repair failed at 0°, 60°, and 90° ( P < .05 for all). For adduction, IPC significantly reduced torque at 0° and reduced stiffness at 0° and 30°; T-cap reduced torque at 0° and 90° and reduced stiffness at all positions; IPC repair failed to restore stiffness at 0° and 90°; and T-cap repair failed at 0°, 60°, and 90° ( P < .05 for all). There were no statistically significant femoral head translations observed in any testing configurations. Conclusion: Complete capsular repair did not always restore intact kinematics, most notably at 0° and 30°. Despite this, there were no significant joint translations to corroborate concerns of microinstability. Clinical Relevance: Caution should be employed when applying rotational torques in lower levels of flexion (0° and 30°).

31 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
LMLipalo Mokete
Lipalo Mokete
ACAlexander Conway
Alexander Conway
EDEmma Donnelly
Emma Donnelly
RWRyan Willing
Ryan Willing
Total knee replacement (TKR) is a reliable treatment for end-stage degenerative conditions of the knee. Patient-reported outcome measures (PROMs) are central to assessing TKR outcomes, but they have limitations. Activities of daily living (ADLs) in the early post-operative period complement PROMs for holistic patient assessment. This study presents a method for capturing ADL parameters from data generated by inertial measurement unit (IMU) devices embedded in TKR prosthesis. A conventional posterior stabilized TKR was modified to create chambers in the femoral and tibial components. The prosthesis was implanted into a cadaver knee and movement was simulated using a hydraulic actuated knee simulator (AMTI, VIVO, MA, USA). A powered IMU device was placed in each of the chambers. The simulator was activated for various ADLs and the generated data was collected wirelessly. The pre-processed data was fed into a novel multimodal deep learning artificial intelligence model created to recognize specific ADL (trained on 70% of the data, with 30% reserved for validation and testing). The model achieved 95.68% overall accuracy, with 100% for sitting, standing, stance, and knee bending. Walking, stair navigation, and jogging showed F1 scores of 0.98, 0.92, 0.91, and 0.89, respectively. This technology enables seamless knee activity recognition and reporting with positive implications for patient-specific rehabilitation protocols.

25 January 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
AGAlexandre Galley
Alexandre Galley
EDEmma Donnelly
Emma Donnelly
IBIlya Borukhov
Ilya Borukhov
BLBrent Lanting
Brent Lanting
RWRyan Willing
Ryan Willing
Knee joint stability comprises passive (ligaments), active (muscles), and static (articular congruency) contributors. The stability of total knee replacement (TKR) implants can be assessed pre-clinically using joint motion simulators. However, contemporary testing methods with these platforms do not accurately reproduce the biomechanical contributions of passive stabilizers, active stabilizers, or both. A key component of joint stability is therefore missing from laxity tests. A recently developed muscle actuator system (MAS) pairs the quadriceps-driven motion capabilities of an Oxford knee simulator with the prescribed displacements and laxity testing methods of a VIVO robotic knee testing system, which also includes virtual ligament capabilities. Using a TKR-embedded non-cadaveric joint analogue, TKR with two different virtual ligament models were compared to TKR with no active ligaments. Laxity limits were then obtained for both developed models using the conventional style of laxity testing (the VIVO’s force/displacement control) and compared with results obtained under similar conditions with the MAS (gravity-dependent muscle control). Differences in joint control methods identified the need for muscle forces providing active joint stability, while differences in the effects of the virtual ligament models identified the importance of physiological representations of collateral ligaments during testing.

28 June 2023 in Arthroscopy
Verified
Journal Article
Closed access
RDRyan M. Degen
Ryan M. Degen
EDEmma Donnelly
Emma Donnelly
ATAsra Toobaie
Asra Toobaie
KNK.C. Geoffrey Ng
K.C. Geoffrey Ng
AGAlan Getgood
Alan Getgood
RWRyan Willing
Ryan Willing

27 October 2025 in Orthopaedic Proceedings
Verified
Journal Article
Closed access
EDEmma Donnelly
Emma Donnelly
MRM. Richards
M. Richards
SVS. Vakili
S. Vakili
SMS. MacDonald
S. MacDonald
RWR. Willing
R. Willing
BLB. Lanting
B. Lanting
Robotic-assisted surgery has become an increasingly attractive option for orthopaedic surgeries, specifically in its use for total knee replacement (TKR). Despite the allure, characterization of the outcomes of robotic-assisted surgery against conventional manual methods remains to be investigated. Therefore, this study aims to characterize kinematics of TKR knees following robotic-assisted and conventional arthroplasty through loaded laxity testing. We hypothesize that robotic-assisted TKR will result in less variable kinematic behavior at end range of motion than its conventional counterparts. Seven pairs of TKR knees were used in this study. For each pair, one surgery was performed using conventional manual methods, while the contralateral side utilized a VELYS robotic-assisted solution (DePuy Synthes). All TKRs were performed by the same surgeon and used a cruciate retaining rotating platform (CR RP) implant system. The knees were mounted onto a VIVO joint motion simulator (Advanced Mechanical Technologies Inc.). Once installed, specimens were pre-conditioned via a baseline loading protocol that involved cycling though the flexion arc from 15 to 90 degrees, while reducing the joint with 30 N of compression. Next, laxity was assessed via applied isolated (1) 4 Nm internal/ external (IE) rotation torques, (2) 8 Nm varus/ valgus (VV) rotation torques, and (3) 40 N anterior, and 80 N posterior forces. Each was performed at discrete positions of 15, 30, 60 and 90 degrees of knee flexion. Laxity outputs were adjusted for joint behavior during baseline to mitigate and mounting biases and account for specimen-specific joint behavior, and conventional TKR and robotic-assisted TKR knees were compared via paired two-tailed t-tests for each combination of flexion angle and tested degree of freedom. At 90° flexion, external rotation laxity was significantly different between the groups (P=0.04), with conventional TKR knees exhibiting greater rotation (26.5° ± 9.1°) than robotic- assisted TKR knees (18.3° ± 3.5°). This is complemented by the observed trend of the difference between conventional and robotic TKR knee external rotation laxity limits increasing with each flexion angle”: 15.8° ± 8.1° [conventional] and 14.1° ± 4.1° [robotic-assisted] at 15 degrees, 20.2° ± 7.2° [conventional] and 18.5° ± 5.6° [robotic-assisted] at 30 degrees, and 21.9° ± 7.2° [conventional] and 19.0° ± 5.2° [robotic-assisted] at 60 degrees. No other statistically significant differences were identified. The results of the current study suggest that while conventionally done TKR may result in comparable joint laxity than those done using conventionally methods, through most of the flexion arc, the latter provides greater stability in external rotation in high flexion (namely 90°). However, observed laxity differences may be compensated for in the opposite direction, resulting in a balanced total laxity envelope. These findings could provide a greater understanding of patient outcomes and inform surgical decision making to cater to a patient's desired functional outcome.