Soft robotic grippers often incorporate pneumatically-driven actuators that can elastically deform to grasp delicate, curved organic objects with minimal surface damage. The complexity of the actuator geometry and the nonlinear stress–strain behavior of the stretchable material during inflation make it difficult to predict actuator performance prior to prototype fabrication. In this work, a scalable modular elastic air-driven actuator made from polydimethylsiloxane (PDMS) is developed for a mechanically compliant robotic gripper that grasps individual horticultural plants and fungi during automated harvesting. The key geometric design parameters include the expandable surface area and wall thickness of the deformable structure used to make contact with the target object. The impact of these parameters on actuator displacement is initially explored through simulation using the Mooney–Rivlin model of hyperelastic materials. In addition, several actuator prototypes with varying expandable wall thicknesses are fabricated using a multistep soft-lithography molding process and are inserted in a closed ring assembly for experimental testing. The gripper performance is evaluated in terms of contact force, contact area with the target, and maximum payload before slippage. The viability of the gripper with PDMS actuators for horticultural harvesting applications is illustrated by gently grasping a variety of mushroom caps.
Knee joint stability comprises passive (ligaments), active (muscles), and static (articular congruency) contributors. The stability of total knee replacement (TKR) implants can be assessed pre-clinically using joint motion simulators. However, contemporary testing methods with these platforms do not accurately reproduce the biomechanical contributions of passive stabilizers, active stabilizers, or both. A key component of joint stability is therefore missing from laxity tests. A recently developed muscle actuator system (MAS) pairs the quadriceps-driven motion capabilities of an Oxford knee simulator with the prescribed displacements and laxity testing methods of a VIVO robotic knee testing system, which also includes virtual ligament capabilities. Using a TKR-embedded non-cadaveric joint analogue, TKR with two different virtual ligament models were compared to TKR with no active ligaments. Laxity limits were then obtained for both developed models using the conventional style of laxity testing (the VIVO’s force/displacement control) and compared with results obtained under similar conditions with the MAS (gravity-dependent muscle control). Differences in joint control methods identified the need for muscle forces providing active joint stability, while differences in the effects of the virtual ligament models identified the importance of physiological representations of collateral ligaments during testing.
17 January 2025 in Journal of Biomechanical Engineering
Total knee replacement (TKR) failure, low patient satisfaction and high revision surgery rates may stem from insufficient preclinical testing. Conventional joint motion simulators for preclinical testing of TKR implants manipulate a knee joint in force, displacement, or simulated muscle control. However, a rig capable of using all three control modes has yet to be described in literature. This study aimed to validate a novel platform, the muscle actuator system (MAS), that can generate gravity-dependent, quadriceps-controlled squatting motions representative of an Oxford rig knee simulator and is mounted onto a force/displacement-control-capable joint motion simulator. Synthetic knee joint phantoms were created that comprised revision TKR implants and key extensor and flexor mechanism analogues, but no ligaments. The combined system implemented a constant force vector acting from simulated hip-to-ankle coordinates, effectively replicating gravity as observed in an Oxford rig. Quadriceps forces and patellofemoral joint kinematics were measured to assess the performance of the MAS and these tests showed high levels of repeatability and reproducibility. Forces and kinematics measured at a nominal patellar tendon length, and with patella alta and baja, were compared against those measured under the same conditions using a conventional Oxford rig, the Pennsylvania State Knee Simulator (PSKS). There was disagreement in absolute kinematics and muscle forces, but similar trends resulting from changing prosthesis design or patellar tendon length.