Rebeca Echeverria-Chasco

Dr. Rebeca Echeverria-Chasco

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
JMJosé María Mora-Gutiérrez
José María Mora-Gutiérrez
MFMaría. A. Fernández-Seara
María. A. Fernández-Seara
RERebeca Echeverria-Chasco
Rebeca Echeverria-Chasco
NGNuria Garcia-Fernandez
Nuria Garcia-Fernandez
Renal magnetic resonance imaging (MRI) techniques are currently in vogue, as they provide in vivo information on renal volume, function, metabolism, perfusion, oxygenation, and microstructural alterations, without the need for exogenous contrast media. New imaging biomarkers can be identified using these tools, which represent a major advance in the understanding and study of the different pathologies affecting the kidney. Diabetic kidney disease (DKD) is one of the most important diseases worldwide due to its high prevalence and impact on public health. However, its multifactorial etiology poses a challenge for both basic and clinical research. Therefore, the use of novel renal MRI techniques is an attractive step forward in the comprehension of DKD, both in its pathogenesis and in its detection and surveillance in the clinical practice. This review article outlines the most promising MRI techniques in the study of DKD, with the purpose of stimulating their clinical translation as possible tools for the diagnosis, follow-up, and monitoring of the clinical impacts of new DKD treatments.

5 October 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
RERebeca Echeverria-Chasco
Rebeca Echeverria-Chasco
MVMarta Vidorreta
Marta Vidorreta
VAVerónica Aramendía‐Vidaurreta
Verónica Aramendía‐Vidaurreta
DCDavid Cano
David Cano
JEJavier Escalada
Javier Escalada
MFMaría. A. Fernández-Seara
María. A. Fernández-Seara

19 January 2024 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
RERebeca Echeverria-Chasco
Rebeca Echeverria-Chasco
PPaloma Martín
Paloma Martín
VAVeronica Aramendía‐Vidaurreta
Veronica Aramendía‐Vidaurreta
LGLeyre Garcia‐Ruiz
Leyre Garcia‐Ruiz
JMJosé María Mora-Gutiérrez
José María Mora-Gutiérrez
MFMaría. A. Fernández-Seara
María. A. Fernández-Seara
Background: Multiparametric MRI provides assessment of functional and structural parameters in kidney allografts. It offers a non‐invasive alternative to the current reference standard of kidney biopsy.Purpose: To evaluate the diagnostic and prognostic utility of MRI parameters in the assessment of allograft function in the first 3‐months post‐transplantation.Study Type: Prospective.Subjects: 32 transplant recipients (54 ± 17 years, 20 females), divided into two groups according to estimated glomerular filtration rate (eGFR) at 3‐months post‐transplantation: inferior graft function (IGF; eGFR<45 mL/min/1.73 m2, n = 10) and superior graft function (SGF; eGFR ≥ 45 mL/min/1.73 m2, n = 22). Further categorization was based on the need for hemodialysis (C1) and decrease in s‐creatinine (C2) at 1‐week post‐transplantation: delayed‐graft‐function (DGF: n = 4 C1, n = 10 C2) and early graft‐function (EGF: n = 28 C1, n = 22 C2).Field Strength/Sequence: 3‐T, pseudo‐continuous arterial spin labeling, T1‐mapping, and diffusion‐weighted imaging.Assessment: Multiparametric MRI was evaluated at 1‐week in all patients and 3‐months after transplantation in 28 patients. Renal blood flow (RBF), diffusion coefficients (ADC, ΔADC, D, D, D*, flowing fraction f), T1 and T1 were calculated in cortex and medulla. The diagnostic and prognostic value of these parameters, obtained at 3‐months and 1‐week post‐transplantation, respectively, was evaluated in the cortex to discriminate between DGF and EGF, and between SGF and IGF.Statistical Tests: Logistic regression, receiver‐operating‐characteristics, area‐under‐the‐curve (AUC), confidence intervals (CIs), analysis‐of‐variance, t‐test, Wilcoxon‐Mann–Whitney test, Fisher's exact test, Pearson's correlation. P‐value<0.05 was considered significant.Results: DGF patients exhibited significantly lower cortical RBF and f and higher D*. The diagnostic value of MRI for detecting DGF was excellent (AUC = 100%). Significant differences between patients with IGF and SGF were found in RBF, ∆T1, and ∆D. Multiparametric MRI showed higher diagnostic (AUC = 95.32%; CI: 88%–100%) and prognostic (AUC = 97.47%, CI: 92%–100%) values for detecting IGF than eGFR (AUC = 89.50%, CI: 79%–100%).Data Conclusion: Multiparametric MRI may show high diagnostic and prognostic value in transplanted patients, yielding better results compared to eGFR measurements.Level of Evidence: 2Technical Efficacy: Stage 1

16 October 2020 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
VAVerónica Aramendía‐Vidaurreta
Verónica Aramendía‐Vidaurreta
RERebeca Echeverria-Chasco
Rebeca Echeverria-Chasco
MVMarta Vidorreta
Marta Vidorreta
GBGorka Bastarrika
Gorka Bastarrika
MFMaría. A. Fernández-Seara
María. A. Fernández-Seara

10 October 2022 in NMR in Biomedicine
Verified
Journal Article
Open access
RERebeca Echeverria-Chasco
Rebeca Echeverria-Chasco
PMPaloma L. Martin‐Moreno
Paloma L. Martin‐Moreno
NGNuria Garcia-Fernandez
Nuria Garcia-Fernandez
MVMarta Vidorreta
Marta Vidorreta
VAVerónica Aramendia‐Vidaurreta
Verónica Aramendia‐Vidaurreta
MFMaria A. Fernández‐Seara
Maria A. Fernández‐Seara
Monitoring renal allograft function after transplantation is key for the early detection of allograft impairment, which in turn can contribute to preventing the loss of the allograft. Multiparametric renal MRI (mpMRI) is a promising noninvasive technique to assess and characterize renal physiopathology; however, few studies have employed mpMRI in renal allografts with stable function (maintained function over a long time period). The purposes of the current study were to evaluate the reproducibility of mpMRI in transplant patients and to characterize normal values of the measured parameters, and to estimate the labeling efficiency of Pseudo‐Continuous Arterial Spin Labeling (PCASL) in the infrarenal aorta using numerical simulations considering experimental measurements of aortic blood flow profiles. The subjects were 20 transplant patients with stable kidney function, maintained over 1 year. The MRI protocol consisted of PCASL, intravoxel incoherent motion, and T1 inversion recovery. Phase contrast was used to measure aortic blood flow. Renal blood flow (RBF), diffusion coefficient (D), pseudo‐diffusion coefficient (D*), flowing fraction ( ), and T1 maps were calculated and mean values were measured in the cortex and medulla. The labeling efficiency of PCASL was estimated from simulation of Bloch equations. Reproducibility was assessed with the within‐subject coefficient of variation, intraclass correlation coefficient, and Bland‐Altman analysis. Correlations were evaluated using the Pearson correlation coefficient. The significance level was p less than 0.05. Cortical reproducibility was very good for T1, D, and RBF, moderate for , and low for D*, while medullary reproducibility was good for T1 and D. Significant correlations in the cortex between RBF and (r = 0.66), RBF and eGFR (r = 0.64), and D* and eGFR (r = −0.57) were found. Normal values of the measured parameters employing the mpMRI protocol in kidney transplant patients with stable function were characterized and the results showed good reproducibility of the techniques.

13 October 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
VAVerónica Aramendía‐Vidaurreta
Verónica Aramendía‐Vidaurreta
PGPedro M. Gordaliza
Pedro M. Gordaliza
MVMarta Vidorreta
Marta Vidorreta
RERebeca Echeverria-Chasco
Rebeca Echeverria-Chasco
GBGorka Bastarrika
Gorka Bastarrika
MFMaría. A. Fernández-Seara
María. A. Fernández-Seara
Purpose: To evaluate the accuracy and reproducibility of myocardial blood flow measurements obtained under different breathing strategies and motion correction techniques with arterial spin labeling.Methods: A prospective cardiac arterial spin labeling study was performed in 12 volunteers at 3 Tesla. Perfusion images were acquired twice under breath‐hold, synchronized‐breathing, and free‐breathing. Motion detection based on the temporal intensity variation of a myocardial voxel, as well as image registration based on pairwise and groupwise approaches, were applied and evaluated in synthetic and in vivo data. A region of interest was drawn over the mean perfusion‐weighted image for quantification. Original breath‐hold datasets, analyzed with individual regions of interest for each perfusion‐weighted image, were considered as reference values.Results: Perfusion measurements in the reference breath‐hold datasets were in line with those reported in literature. In original datasets, prior to motion correction, myocardial blood flow quantification was significantly overestimated due to contamination of the myocardial perfusion with the high intensity signal of blood pool. These effects were minimized with motion detection or registration. Synthetic data showed that accuracy of the perfusion measurements was higher with the use of registration, in particular after the pairwise approach, which probed to be more robust to motion.Conclusion: Satisfactory results were obtained for the free‐breathing strategy after pairwise registration, with higher accuracy and robustness (in synthetic datasets) and higher intrasession reproducibility together with lower myocardial blood flow variability across subjects (in in vivo datasets). Breath‐hold and synchronized‐breathing after motion correction provided similar results, but these breathing strategies can be difficult to perform by patients.