Carlotta Caccio'

Ms. Carlotta Caccio'


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
Marco TallaricoMarco Tallarico
Marco Tallarico
MQMohammad Qaddomi
Mohammad Qaddomi
ERElena De Rosa
Elena De Rosa
CCCarlotta Caccio'
Carlotta Caccio'
YJYeo Jin Jung
Yeo Jin Jung
MPMilena Pisano
Milena Pisano
Background/Objectives: Digital workflows for implant-supported full-arch restorations remain challenging. This study evaluated the accuracy and precision of digital impressions using reverse scan body (RSB) prototypes and intraoral scanners (IOSs) for rehabilitating fully edentulous patients following the All-on-4 protocol. Secondary objectives included comparing accuracy between expert clinicians and beginners, as well as desktop scanners and various RSB designs. Methods: An in vitro study was conducted using a fully edentulous mandible model with four Osstem TSIII implants. A final-year dental student and an expert clinician captured digital impressions using IOSs and desktop scanners. Four groups were analyzed: (A) original scan bodies with the IOS, (B) short RSBs with the IOS, (C) RSBs with desktop scanners (short sandblasted, long sandblasted, long coated), and (D) a control group using original scan bodies with a desktop scanner. Root mean square (RMS) values measured dimensional differences, with statistical analysis performed using the Wilcoxon signed-rank test and one-way ANOVA (α = 0.05). Results: A total of 42 scans were analyzed. No significant difference was found between expert and student for original scan bodies using the IOS (p = 0.220), while RSB prototypes showed significant differences (p = 0.008). No significant accuracy differences were noted between original scan bodies and RSBs with the IOS, but IOSs outperformed desktop scanners. Among RSBs scanned with desktop scanners, no significant differences were observed between designs. Conclusions: RSB prototypes are a viable alternative to original scan bodies for fully digital workflows in All-on-4 rehabilitations, with IOSs offering superior accuracy. However, proper training is crucial for optimizing RSB accuracy. Variations in height and coating did not impact overall accuracy.

9 October 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Marco TallaricoMarco Tallarico
Marco Tallarico
MQMohammad Qaddomi
Mohammad Qaddomi
ERElena De Rosa
Elena De Rosa
CCCarlotta Caccio'
Carlotta Caccio'
Silvio Mario MeloniSilvio Mario Meloni
Silvio Mario Meloni
Gabriele CervinoGabriele Cervino
Gabriele Cervino
Background: The accuracy and consistency of complete-arch digital impressions are fundamental for long-term success of implant-supported rehabilitations. Recently, artificial intelligence (AI)-assisted tools, such as SmartX (Medit Link v3.4.2, MEDIT Corp., Seoul, South of Korea), have been introduced to enhance scan body recognition and data alignment during intraoral scanning. Objective: This in vitro study aimed to evaluate the impact of SmartX on impression accuracy, consistency, operator confidence, and technique sensitivity in complete-arch implant workflows. Methods: Seventy-two digital impressions were recorded on edentulous mandibular models with four dummy implants, using six experimental subgroups based on scan body design (double- or single-wing), scanning technique (occlusal or combined straight/zigzag), and presence/absence of SmartX tool. Each group was scanned by both an expert and a novice operator (n = 6 scans per subgroup). Root mean square (RMS) deviation and scanning time were assessed. Data were tested for normality (Shapiro–Wilk). Parametric tests (t-test, repeated measures ANOVA with Greenhouse–Geisser correction) or non-parametric equivalents (Mann–Whitney U, Friedman) were applied as appropriate. Post hoc comparisons used Tukey HSD or Dunn–Bonferroni tests (α = 0.05). Results: SmartX significantly improved consistency and operator confidence, especially among novices, although it did not yield statistically significant differences in scan accuracy (p > 0.05). The tool mitigated early scanning errors and reduced dependence on operator technique. SmartX also enabled successful library alignment with minimal data; however, scanning time was generally longer with its use, particularly for beginners. Conclusions: While SmartX did not directly enhance trueness, it substantially improved scan reliability and user experience in complete-arch workflows. Its ability to minimize technique sensitivity and improve reproducibility makes it a valuable aid in both training and clinical settings. Further clinical validation is warranted to support its integration into routine practice.

25 March 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Marco TallaricoMarco Tallarico
Marco Tallarico
Silvio Mario MeloniSilvio Mario Meloni
Silvio Mario Meloni
MTMichele Troia
Michele Troia
CCCarlotta Caccio'
Carlotta Caccio'
ALAurea Maria Immacolata Lumbau
Aurea Maria Immacolata Lumbau
MPMilena Pisano
Milena Pisano
Background/Objectives: We wished to evaluate in vitro whether vacuum plasma surface treatment of bone graft substitutes and resorbable membranes could improve the hydrophilicity and wettability of the tested materials. Methods: A total of 28 sterilized samples were considered for this research and divided into three groups. Six samples were used for the SEM-EDS analysis. The other 22 samples were randomly assigned into the test (plasma-treated, n = 11) and control (no treatment, n = 11) groups. Vacuum plasma surface treatment was performed in the test group before the SEM-EDS analysis using the ACTILINK reborn with a material holder (Plasmapp Co., Ltd., Daejeon, Republic of Korea). Plasmatreat (Plasmatreat, Steinhagen, Germany) inks were used to evaluate the differences in the hydrophilicity between the test and control groups. The outcome measures were the absorption time, wettability grade, and grade of decontamination after different time cycles. Results: After the vacuum plasma surface treatment, the absorption time of the inks statistically decreased in all of the subgroups (p < 0.05), while the wettability grade increased. The SEM-EDS analyses showed an increased reduction rate of carbon impurities after up to three vacuum plasma surface treatment cycles. Furthermore, the SEM-EDS analysis did not reveal any areas of damage caused by the multiple treatments. Conclusions: Within the limitations of this in vitro study, the vacuum plasma surface treatment increased the hydrophilicity and wettability of the tested biomaterials. Particle bone graft and bone blocks should be treated using longer time programs. Further well-conducted randomized clinical trials with sample size calculations are needed to confirm these preliminary results.

21 June 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
Marco TallaricoMarco Tallarico
Marco Tallarico
ALAurea Maria Immacolata Lumbau
Aurea Maria Immacolata Lumbau
MSMariapia Sorrenti
Mariapia Sorrenti
RLRoberta Lione
Roberta Lione
CCCarlotta Caccio'
Carlotta Caccio'
MPMilena Pisano
Milena Pisano
Background: Aesthetic dentistry increasingly demands minimally invasive, predictable, and patient-centered solutions. Digital technologies and AI-driven planning tools are now integral to interdisciplinary treatments. Aim: To evaluate, by means of a 16-item questionnaire, patients’ perceptions of smile aesthetics and oral function before and after receiving clear aligner therapy followed by minimally invasive ceramic veneers, using digital planning and Smile Creator software. Materials and Methods: Five adult patients underwent digital smile design, clear aligner therapy, and feldspathic veneer placement. Pre- and post-treatment perceptions of smile aesthetics and function were assessed using a structured questionnaire. AI-based simulation tools (2D and 4 K TruSmile video previews) were incorporated. Paired t-tests were used to compare outcomes before and after treatment. Results: Mean pre-treatment scores were 4.8 for smile aesthetics and 6.6 for function. Post-treatment scores significantly improved to 9.8 (p = 0.001) and 9.4 (p = 0.002), respectively. Patients rated AI-generated smile previews more favorably than 2D designs and acknowledged the value of digital tools in understanding and accepting treatment. Conclusions: The integration of digital and AI-based tools in aesthetic dentistry enhances patient communication, improves predictability, and enables minimally invasive treatment. Patient satisfaction was high, underscoring the effectiveness of the combined orthodontic and prosthetic approach.

22 July 2025 in Reports
Verified
Journal Article
Open access
PDF file
Marco TallaricoMarco Tallarico
Marco Tallarico
Silvio Mario MeloniSilvio Mario Meloni
Silvio Mario Meloni
CCCarlotta Caccio'
Carlotta Caccio'
FCFrancesco Mattia Ceruso
Francesco Mattia Ceruso
ALAurea Maria Immacolata Lumbau
Aurea Maria Immacolata Lumbau
Background and Clinical Significance: The retreatment of failed dental implants remains a challenging clinical scenario, particularly when complicated by peri-implantitis and as sociated bone loss. Successful management requires a comprehensive and predictable approach that addresses both hard and soft tissue deficiencies. Case Presentation: This case report illustrates a fully digital, prosthetically driven workflow for the rehabilitation of a posterior mandibular site following implant failure. A 44-year-old female patient underwent removal of a failing implant and adjacent tooth due to advanced peri-implantitis and periodontitis. After healing, a digital workflow—including intraoral scanning, cone-beam computed tomography (CBCT), and virtual planning—was employed to design and fabricate a customized CAD/CAM titanium mesh for vertical guided bone regeneration. The grafting procedure utilized a composite mixture of autogenous bone and anorganic bovine bone (A-Oss). After nine months of healing, two implants with a hydrophilic surface (SOI) were placed using a fully guided surgical protocol (OneGuide system). Subsequent soft tissue grafting and final prosthetic rehabilitation with monolithic zirconia restorations resulted in stable functional and aesthetic outcomes. Conclusions: This case highlights how the integration of modern digital technologies with advanced regenerative procedures and innovative implant surfaces can enhance the predictability and long-term success of implant retreatment in compromised posterior sites.

8 July 2025 in Reports
Verified
Journal Article
Open access
PDF file
CCCarlotta Caccio'
Carlotta Caccio'
Marco TallaricoMarco Tallarico
Marco Tallarico
ALAurea Maria Immacolata Lumbau
Aurea Maria Immacolata Lumbau
FCFrancesco Mattia Ceruso
Francesco Mattia Ceruso
MPMilena Pisano
Milena Pisano
Background and Clinical Significance: Prosthetic rehabilitation in the aesthetic zone of periodontally compromised patients presents a complex clinical challenge, requiring a careful coordination of aesthetic, functional, and biological demands. This case highlights the benefits of digital dentistry, interdisciplinary collaboration, and regular maintenance in achieving long-term success in complex rehabilitations of periodontally compromised patients. Case Presentation: This case report describes the digital minimally invasive rehabilitation of a 39-year-old male patient with Stage III periodontitis, occlusal discrepancies, tooth mobility, and an interincisal diastema. A fully digital workflow—including intraoral scanning, aesthetic previewing, and mandibular motion analysis—was employed to guide diagnosis, treatment planning, and prosthetic execution. Conservative tooth preparations using a biologically oriented approach (BOPT) were combined with customised provisional restorations to support soft tissue conditioning and functional control throughout the provisional phases. Mandibular motion tracking facilitated the design of a personalised anterior guidance to improve occlusion and correct the deep bite. The interincisal diastema was initially maintained then closed during the advanced phase of treatment based on aesthetic simulations and patient preference. One unplanned endodontic treatment was required during the provisional phase, but no other complications occurred. Conclusions: At the four-year follow-up, the patient demonstrated stable periodontal and occlusal conditions, improved clinical indices, and high satisfaction with the aesthetic outcome.