Francesco Mattia Ceruso

Dr. Francesco Mattia Ceruso


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ABAndrea Ballini
Andrea Ballini
MCMichele Di Cosola
Michele Di Cosola
RSRajiv Saini
Rajiv Saini
CBCaterina Benincasa
Caterina Benincasa
EAElisabetta Aiello
Elisabetta Aiello
SCStefania Cantore
Stefania Cantore
Background: It is well-known that toothbrushing might be associated with the development of oral soft tissue lesions. There is currently a continuing increase in the demand for new safety and performing materials in daily homecare oral hygiene including soft and extra-soft toothbrush bristles that tend to be safer. The aim of this study was to compare the efficacy of plaque control and the potential effects on gingival health of two different toothbrush bristle models. Methods: In a three-month period, a total of forty subjects were evaluated for Oral Hygiene Index (OHI), Gingival Index (GI) and Plaque Index (PI) scores as well the Gingival Abrasion Assessment (GAA) between a toothbrush entirely made from a rubber-like material called thermoplastic elastomer (TPE) and a soft toothbrush (standard control with nylon bristles) in a clinical, single-blind, controlled, parallel-group trial. Results: The use of the TPE toothbrush allows a reduction in the PI, improves the OHI and modifies the GAA in the TPE group over a period of three months compared with a conventional soft bristle toothbrush applied for the same period, leading in this way evidence for a good influence of the TPE bristles on overall oral hygiene conditions. Conclusions: From the comparison between our data and the literature studies, we can state that the material and shape of the bristles of the toothbrush affect the home practice of oral hygiene. The TPE bristles reduce the presence of plaque formation and gingival bleeding, oral soft tissue injuries acquired during homecare oral hygiene.

10 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
FCFrancesco Mattia Ceruso
Francesco Mattia Ceruso
IIIrene Ieria
Irene Ieria
Marco TallaricoMarco Tallarico
Marco Tallarico
Silvio Mario MeloniSilvio Mario Meloni
Silvio Mario Meloni
ALAurea Maria Immacolata Lumbau
Aurea Maria Immacolata Lumbau
MGMarco Gargari
Marco Gargari
To evaluate the implant and prosthetic of two implants with different surfaces and neck design. Enrolled patients received bone level, 12° conical connection implants (Nobel Parallel, Nobel Biocare; NOBEL group) with anodized surface (TiUnite) and roughness of 1.35 μm, or transmucosal implant system (Prama, Sweden and Martina; PRAMA group) with convergent collar, ZIrTi surface, and roughness 1.4–1.7 μm. Both implants were made of pure grade IV titanium, with similar diameter and length, chosen according to the dentistry department availability and patient’s request. After early prosthesis delivery, patients were filled for at least one year. Outcome measures were: implant and prosthetic survival and success rates, physiological marginal bone remodeling, periodontal parameters and pink esthetic score (PES). Results: Fifteen patients were allocated and treated in each group. At the one-year follow-up, three patients dropped out, one in the NOBEL group and two in the PRAMA group. During the entire time of investigation, all implants survived and the prostheses were successful. No statistically significant differences were found in term of marginal bone loss, periodontal parameters, and aesthetics (p > 0.05). Conclusion: With the limitations of the present study, both implant systems showed successful clinical results. Finally, many other clinical and surgical variables may influenced marginal bone levels, implant survival, and periodontal parameters. More homogenous clinical trials with larger samples are needed to confirm these preliminary conclusions.

31 March 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
Marco TallaricoMarco Tallarico
Marco Tallarico
MQMohammad Qaddomi
Mohammad Qaddomi
ERElena De Rosa
Elena De Rosa
CCCarlotta Caccio'
Carlotta Caccio'
YJYeo Jin Jung
Yeo Jin Jung
MPMilena Pisano
Milena Pisano
Background/Objectives: Digital workflows for implant-supported full-arch restorations remain challenging. This study evaluated the accuracy and precision of digital impressions using reverse scan body (RSB) prototypes and intraoral scanners (IOSs) for rehabilitating fully edentulous patients following the All-on-4 protocol. Secondary objectives included comparing accuracy between expert clinicians and beginners, as well as desktop scanners and various RSB designs. Methods: An in vitro study was conducted using a fully edentulous mandible model with four Osstem TSIII implants. A final-year dental student and an expert clinician captured digital impressions using IOSs and desktop scanners. Four groups were analyzed: (A) original scan bodies with the IOS, (B) short RSBs with the IOS, (C) RSBs with desktop scanners (short sandblasted, long sandblasted, long coated), and (D) a control group using original scan bodies with a desktop scanner. Root mean square (RMS) values measured dimensional differences, with statistical analysis performed using the Wilcoxon signed-rank test and one-way ANOVA (α = 0.05). Results: A total of 42 scans were analyzed. No significant difference was found between expert and student for original scan bodies using the IOS (p = 0.220), while RSB prototypes showed significant differences (p = 0.008). No significant accuracy differences were noted between original scan bodies and RSBs with the IOS, but IOSs outperformed desktop scanners. Among RSBs scanned with desktop scanners, no significant differences were observed between designs. Conclusions: RSB prototypes are a viable alternative to original scan bodies for fully digital workflows in All-on-4 rehabilitations, with IOSs offering superior accuracy. However, proper training is crucial for optimizing RSB accuracy. Variations in height and coating did not impact overall accuracy.

25 March 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Marco TallaricoMarco Tallarico
Marco Tallarico
Silvio Mario MeloniSilvio Mario Meloni
Silvio Mario Meloni
MTMichele Troia
Michele Troia
CCCarlotta Caccio'
Carlotta Caccio'
ALAurea Maria Immacolata Lumbau
Aurea Maria Immacolata Lumbau
MPMilena Pisano
Milena Pisano
Background/Objectives: We wished to evaluate in vitro whether vacuum plasma surface treatment of bone graft substitutes and resorbable membranes could improve the hydrophilicity and wettability of the tested materials. Methods: A total of 28 sterilized samples were considered for this research and divided into three groups. Six samples were used for the SEM-EDS analysis. The other 22 samples were randomly assigned into the test (plasma-treated, n = 11) and control (no treatment, n = 11) groups. Vacuum plasma surface treatment was performed in the test group before the SEM-EDS analysis using the ACTILINK reborn with a material holder (Plasmapp Co., Ltd., Daejeon, Republic of Korea). Plasmatreat (Plasmatreat, Steinhagen, Germany) inks were used to evaluate the differences in the hydrophilicity between the test and control groups. The outcome measures were the absorption time, wettability grade, and grade of decontamination after different time cycles. Results: After the vacuum plasma surface treatment, the absorption time of the inks statistically decreased in all of the subgroups (p < 0.05), while the wettability grade increased. The SEM-EDS analyses showed an increased reduction rate of carbon impurities after up to three vacuum plasma surface treatment cycles. Furthermore, the SEM-EDS analysis did not reveal any areas of damage caused by the multiple treatments. Conclusions: Within the limitations of this in vitro study, the vacuum plasma surface treatment increased the hydrophilicity and wettability of the tested biomaterials. Particle bone graft and bone blocks should be treated using longer time programs. Further well-conducted randomized clinical trials with sample size calculations are needed to confirm these preliminary results.

24 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
RLRoberto Luongo
Roberto Luongo
Marco TallaricoMarco Tallarico
Marco Tallarico
Elena CancianiElena Canciani
Elena Canciani
DGDaniele Graziano
Daniele Graziano
Claudia DellaviaClaudia Dellavia
Claudia Dellavia
Luigi CanulloLuigi Canullo
Luigi Canullo
Aim: The aim of the present study was to investigate quantitative histological examination of bone reconstructed with non-resorbable high-density polytetrafluoroethylene membrane (d-PTFE), left intentionally exposed in post extraction sockets grafted with anorganic bone material, and removed after four weeks, versus extraction and guided bone regeneration (GBR), performed two months later. Materials and Methods: This study was designed as a multicenter randomized controlled trial of parallel-group design. Patients were selected and consecutively treated in three centers in Italy. Patients randomly received intentionally exposed non-resorbable d-PTFE membrane (group A), or guided bone regeneration (group B), to treat post-extractive alveolar bone defects with implant-supported restorations. Outcomes were: the implant failure, any mechanical and biological complications, patient satisfaction, and qualitative and histomorphometric evaluation of the collected bone samples. Results: Eighteen patients were consecutively enrolled in the trial. Of these, six out of 18 patients were male. All the included patients were treated according to the allocated interventions, and no drop out occurred. No implant failure and no complications were experienced, and all the patients were fully satisfied with the function and aesthetic of their implant-supported restoration, without difference between groups. Morphological analysis revealed no sign of tissue reaction, such as fibrosis or necrosis. Regenerated bone was well mineralized in both groups, but it seemed more mature in group B than in group A. Three samples showed a minimal number of lymphocytes. Several blood vessels of small size occupied the medullary spaces, where the tissue resulted in more maturity, indicating the activity of the tissue in progress. The histomorphometric evaluation showed no statistically significant differences in the tissue volume fractions between the two groups of patients. Conclusions: With the limitation of the present study, buccal plate reconstruction with an intentionally exposed non-resorbable membrane is an effective and easy procedure for regenerating a resorbed buccal bone plate, reducing the need for guided bone regeneration.

28 April 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
FCFrancesco Mattia Ceruso
Francesco Mattia Ceruso
ALAurea Maria Immacolata Lumbau
Aurea Maria Immacolata Lumbau
FPFrancesco Pernice
Francesco Pernice
AMAlessandro Mastroianni
Alessandro Mastroianni
MMMichele Miranda
Michele Miranda
MPMilena Pisano
Milena Pisano
Objectives: This retrospective study aimed to evaluate the increase in vertical bone height following sinus lift procedures using the CAS (Crestal Approach Sinus) kit technique in combination with tissue-level implants. Additionally, the quantity of bone between the implant apex and the Schneiderian membrane was assessed to determine the effectiveness and safety of this minimally invasive approach. Methods: The study included 15 patients (20 implants) who underwent sinus lift procedures with the CAS kit technique and tissue-level implants in the posterior maxilla between September 2021 and October 2024. Inclusion criteria required a minimum residual bone height (RBH) of 2 mm. Cone-beam computed tomography (CBCT) scans were used for initial screening, and panoramic radiography evaluated outcomes at implant placement and nine months postoperatively. Primary outcomes included implant and prosthetic survival rates, as well as biological and technical complications. Secondary outcomes were vertical bone height and the amount of bone above the implant tip. Statistical analyses were conducted using the Wilcoxon signed-rank test with a significance level of 0.05. Results: All implants achieved successful osseointegration, with no implant or prosthetic failures and no biological or technical complications reported. The mean RBH at implant placement was 4.2 ± 1.4 mm, which increased to an overall membrane elevation of 13.8 ± 1.8 mm. At the 9-month follow-up, the overall membrane elevation was slightly reduced to 13.0 ± 1.6 mm (p = 0.000), with a mean bone gain of 9.6 ± 2.4 mm. The amount of bone above the implant tip was 3.4 ± 1.7 mm at placement, decreasing to 3.0 ± 1.2 mm at follow-up (p = 0.007). Conclusions: The CAS kit technique combined with tissue-level implants demonstrated significant vertical bone gain and high implant survival rates without complications. This minimally invasive approach proved effective and safe for sinus augmentation in patients with limited residual bone height. The findings support the CAS kit’s potential as a preferred technique for maxillary sinus elevation. Further research with larger cohorts and long-term follow-up is needed to validate these results.