The journey of a prosthetic user is characterized by the opportunities and the limitations of a device that should enable activities of daily living (ADL). In particular, experiencing a bionic hand as a functional (and, advantageously, embodied) limb constitutes the premise for promoting the practice in using the device, mitigating the risk of its abandonment. In order to achieve such a result, different aspects need to be considered for making the artificial limb an effective solution to accomplish ADL. According to such a perspective, this review aims at presenting the current issues and at envisioning the upcoming breakthroughs in upper limb prosthetic devices. We first define the sources of input and feedback involved in the system control (at user-level and device-level), alongside the related algorithms used in signal analysis. Moreover, the paper focuses on the user-centered design challenges and strategies that guide the implementation of novel solutions in this area in terms of technology acceptance, embodiment, and, in general, human-machine integration based on co-adaptive processes. We here provide the readers (belonging to the target communities of researchers, designers, developers, clinicians, industrial stakeholders, and end-users) with an overview of the state-of-the-art and the potential innovations in bionic hands features, hopefully promoting interdisciplinary efforts for solving current issues of upper limb prostheses. The integration of different perspectives should be the premise to a transdisciplinary intertwining leading to a truly holistic comprehension and improvement of the bionic hands design. Overall, this paper aims to move the boundaries in prosthetic innovation beyond the development of a tool and toward the engineering of human-centered artificial limbs.
1 December 2023 in IEEE Transactions on Medical Robotics and Bionics
Developing a prosthetic system that emulates the complexity of the human upper limb is a formidable challenge. Unfortunately, abandonment rates for such devices remain high, primarily due to the limited intuitiveness of control and poor dexterity. Specifically, inadequate wrist mobility, i.e., the absence of actively controllable flexion-extension and pronation-supination degrees of freedom, often results in subpar dexterity in upper limb prostheses. This work introduces an anthropomorphic wrist prosthesis featuring active flexion-extension and pronation-supination capabilities, integrated with the poly-articulated Hannes hand. The central focus of this study is to compare the functionality of this prosthetic system with the natural wrist movement of healthy participants, demonstrating that the biomechanical range of motion falls within that of the mechatronic system. The overarching goal is to improve the performance of trans-radial prostheses by enhancing their dexterity and overall functionality. Our preliminary findings from healthy subjects demonstrate that the incorporation of a 2 Degrees-of-Freedom active biomimetic wrist into the prosthesis can approximate human-like capabilities in upper limb prostheses. Moreover, the resulting development confirm its enhanced dexterity when operated by amputees. These results provide valuable insights into the potential applications of this technology for amputees, offering a basis for future investigations.
28 August 2024 in IEEE Robotics and Automation Letters
Noninvasive human-machine interfaces such as surface electromyography (sEMG) have long been employed for controlling robotic prostheses. However, classical controllers are limited to few degrees of freedom (DoF). More recently, machine learning methods have been proposed to learn personalized controllers from user data. While promising, they often suffer from distribution shift during long-term usage, requiring costly model re-training. Moreover, most prosthetic sEMG sensors have low spatial density, which limits accuracy and the number of controllable motions. In this work, we address both challenges by introducing a novel myoelectric prosthetic system integrating a high density-sEMG (HD-sEMG) setup and incremental learning methods to accurately control 7 motions of the Hannes prosthesis. First, we present a newly designed, compact HD-sEMG interface equipped with 64 dry electrodes positioned over the forearm. Then, we introduce an efficient incremental learning system enabling model adaptation on a stream of data. We thoroughly analyze multiple learning algorithms across 7 subjects, including one with limb absence, and 6 sessions held in different days covering an extended period of several months. The size and time span of the collected data represent a relevant contribution for studying long-term myocontrol performance. Therefore, we release the DELTA dataset together with our experimental code.
Objective. We analyze and interpret arm and forearm muscle activity in relation with the kinematics of hand pre-shaping during reaching and grasping from the perspective of human synergistic motor control. Approach. Ten subjects performed six tasks involving reaching, grasping and object manipulation. We recorded electromyographic (EMG) signals from arm and forearm muscles with a mix of bipolar electrodes and high-density grids of electrodes. Motion capture was concurrently recorded to estimate hand kinematics. Muscle synergies were extracted separately for arm and forearm muscles, and postural synergies were extracted from hand joint angles. We assessed whether activation coefficients of postural synergies positively correlate with and can be regressed from activation coefficients of muscle synergies. Each type of synergies was clustered across subjects. Main results. We found consistency of the identified synergies across subjects, and we functionally evaluated synergy clusters computed across subjects to identify synergies representative of all subjects. We found a positive correlation between pairs of activation coefficients of muscle and postural synergies with important functional implications. We demonstrated a significant positive contribution in the combination between arm and forearm muscle synergies in estimating hand postural synergies with respect to estimation based on muscle synergies of only one body segment, either arm or forearm (p < 0.01). We found that dimensionality reduction of multi-muscle EMG root mean square (RMS) signals did not significantly affect hand posture estimation, as demonstrated by comparable results with regression of hand angles from EMG RMS signals. Significance. We demonstrated that hand posture prediction improves by combining activity of arm and forearm muscles and we evaluate, for the first time, correlation and regression between activation coefficients of arm muscle and hand postural synergies. Our findings can be beneficial for myoelectric control of hand prosthesis and upper-limb exoskeletons, and for biomarker evaluation during neurorehabilitation.
14 June 2023 in IEEE Transactions on Biomedical Engineering
Objective: The bidirectional communication between the user and the prosthesis is an important requirement when developing prosthetic hands. Proprioceptive feedback is fundamental to perceiving prosthesis movement without the need for constant visual attention. We propose a novel solution to encode wrist rotation using a vibromotor array and Gaussian interpolation of vibration intensity. The approach generates tactile sensation that smoothly rotates around the forearm congruently with prosthetic wrist rotation. The performance of this scheme was systematically assessed for a range of parameter values (number of motors and Gaussian standard deviation). Methods : Fifteen non-disabled subjects and one individual with congenital limb deficiency used vibrational feedback to control a virtual hand in the target-achievement control test. Performance was assessed by end-point error and efficiency as well as subjective impressions. Results : The results showed a preference for smooth feedback and a higher number of motors (8 and 6 versus 4). With 8 and 6 motors, the standard deviation, determining the sensation spread and continuity, could be modulated through a broad range of values (0.1 - 2) without a significant performance loss. The overall average error and efficiency across these feedback configurations were ∼ 10% and ∼ 30%, respectively. For low values of standard deviation (0.1-0.5), the number of motors could be reduced to 4 without a significant performance decrease. Conclusion: The study demonstrated that the developed strategy provided meaningful rotation feedback. Moreover, the results indicate that the Gaussian standard deviation could be used as an independent parameter to encode an additional feedback variable. Significance: The proposed method is a flexible and effective approach to provide proprioceptive feedback while adjusting the trade-off between sensation quality and the number of vibromotors.
Upper-limb movement characterization is crucial for many applications, from research on motor control, to the extraction of relevant features for driving active prostheses. While this is usually performed using electrophysiological and/or kinematic measurements only, the collection of tactile data during grasping movements could enrich the overall information about interaction with external environment. We provide a dataset collected from 10 healthy volunteers performing 16 tasks, including simple movements (i.e., hand opening/closing, wrist pronation/supination and flexion/extension, tridigital grasping, thumb abduction, cylindrical and spherical grasping) and more complex ones (i.e., reaching and grasping). The novelty consists in the inclusion of several types of recordings, namely electromyographic -both with bipolar and high-density configuration, kinematic-both with motion capture system and a sensorized glove, and tactile. The data is organized following the Brain Imaging Data Structure standard format and have been validated to ensure its reliability. It can be used to investigate upper-limb movements in physiological conditions, and to test sensor fusion approaches and control algorithms for prosthetics and robotic applications.