Angus B. Clark

Dr. Angus B. Clark

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2020 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
Qiujie LuQiujie Lu
Qiujie Lu
ACAngus B. Clark
Angus B. Clark
MSMatthew Shen
Matthew Shen
NRNicolas Rojas
Nicolas Rojas
While the grasping capability of robotic grippers has shown significant development, the ability to manipulate objects within the hand is still limited. One explanation for this limitation is the lack of controlled contact variation between the grasped object and the gripper. For instance, human hands have the ability to firmly grip object surfaces, as well as slide over object faces, an aspect that aids the enhanced manipulation of objects within the hand without losing contact. In this letter, we present a parametric, origami-inspired thin surface capable of transitioning between a high friction and a low friction state, suitable for implementation as an epidermis in robotic fingers. A numerical analysis of the proposed surface based on its design parameters, force analysis, and performance in in-hand manipulation tasks is presented. Through the development of a simple two-fingered two-degree-of-freedom gripper utilizing the proposed variable-friction surfaces with different parameters, we experimentally demonstrate the improved manipulation capabilities of the hand when compared to the same gripper without changeable friction. Results show that the pattern density and valley gap are the main parameters that effect the in-hand manipulation performance. The origami-inspired thin surface with a higher pattern density generated a smaller valley gap and smaller height change, producing a more stable improvement of the manipulation capabilities of the hand.

22 October 2021 in The International Journal of Robotics Research
Verified
Journal Article
Open access
PDF file
Qiujie LuQiujie Lu
Qiujie Lu
NBNicholas Baron
Nicholas Baron
ACAngus B. Clark
Angus B. Clark
NRNicolas Rojas
Nicolas Rojas
We introduce a reconfigurable underactuated robot hand able to perform systematic prehensile in-hand manipulations regardless of object size or shape. The hand utilizes a two-degree-of-freedom five-bar linkage as the palm of the gripper, with three three-phalanx underactuated fingers, jointly controlled by a single actuator, connected to the mobile revolute joints of the palm. Three actuators are used in the robot hand system in total, one for controlling the force exerted on objects by the fingers through an underactuated tendon system, and two for changing the configuration of the palm and, thus, the positioning of the fingers. This novel layout allows decoupling grasping and manipulation, facilitating the planning and execution of in-hand manipulation operations. The reconfigurable palm provides the hand with a large grasping versatility, and allows easy computation of a map between task space and joint space for manipulation based on distance-based linkage kinematics. The motion of objects of different sizes and shapes from one pose to another is then straightforward and systematic, provided the objects are kept grasped. This is guaranteed independently and passively by the underactuated fingers using a custom tendon routing method, which allows no tendon length variation when the relative finger base positions change with palm reconfigurations. We analyze the theoretical grasping workspace and grasping and manipulation capability of the hand, present algorithms for computing the manipulation map and in-hand manipulation planning, and evaluate all these experimentally. Numerical and empirical results of several manipulation trajectories with objects of different size and shape clearly demonstrate the viability of the proposed concept.

18 March 2019 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
ACAngus B. Clark
Angus B. Clark
NRNicolas Rojas
Nicolas Rojas
Variable stiffness continuum structures of large diameter are suitable for high-capability robots, such as in industrial practices where high loads and human-robot interaction are expected. Existing variable stiffness technologies have focused on application as medical manipulators, and as such have been limited to small diameter designs (~15mm). Various performance metrics have been presented for continuum structures thus far, focusing on force resistance, but no universal testing methodology for continuum structures that encapsulates their overall performance has been provided. This paper presents five individual qualities that can be experimentally quantified to establish the overall performance capability of a design with respect to its use as a variable stiffness continuum manipulator. Six large diameter (>40mm) continuum structures are developed following both conventional (granular and layer jamming) and novel (hybrid designs and structurally supported layer jamming) approaches, and are compared using the presented testing methodology. The development of the continuum structures is discussed, and a detailed insight into the tested quality selection and experimental methodology is presented. Results of experiments demonstrate the suitability of the proposed approach for assessing variable stiffness continuum capability across design.

14 February 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
DCDigby Chappell
Digby Chappell
HSHonn Wee Son
Honn Wee Son
ACAngus B. Clark
Angus B. Clark
ZYZeyu Yang
Zeyu Yang
FBFernando Bello
Fernando Bello
NRNicolas Rojas
Nicolas Rojas
Virtual reality (VR) rehabilitation systems have been proposed to enable prosthetic hand users to perform training before receiving their prosthesis. Improving pre-prosthetic training to be more representative and better prepare the patient for prosthesis use is a crucial step forwards in rehabilitation. However, existing VR platforms lack realism and accuracy in terms of the virtual hand and the forces produced when interacting with the environment. To address these shortcomings, this work presents a VR training platform based on accurate simulation of an anthropomorphic prosthetic hand, utilising an external robot arm to render realistic forces that the user would feel at the attachment point of their prosthesis. Experimental results with non-disabled participants show that training with this platform leads to a significant improvement in Box and Block scores compared to training in VR alone and a control group with no prior training. Results performing pick-and-place tasks with a wider range of objects demonstrates that training in VR alone negatively impacts performance, whereas the proposed platform has no significant impact on performance. User perception results highlight that the platform is much closer to using a physical prosthesis in terms of physical demand and effort, however frustration is significantly higher during training.

30 November 2020 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
ACAngus B. Clark
Angus B. Clark
VMVisakan Mathivannan
Visakan Mathivannan
NRNicolas Rojas
Nicolas Rojas
Many have explored the application of continuum robot manipulators for minimally invasive surgery, and have successfully demonstrated the advantages their flexible design provides—with some solutions having reached commercialisation and clinical practice. However, the usual high complexity and closed-nature of such designs has traditionally restricted the shared development of continuum robots across the research area, thus impacting further progress and the solution of open challenges. In order to close this gap, this paper introduces ENDO, an open-source 3-segment continuum robot manipulator with control and actuation mechanism, whose focus is on simplicity, affordability, and accessibility. This robotic system is fabricated from low cost off-the-shelf components and rapid prototyping methods, and its information for implementation (and that of future iterations), including CAD files and source code, is available to the public on the https://github.com/OpenSourceMedicalRobots’s repository on GitHub, with the control library also available directly from Arduino. Herein, we present details of the robot design and control, validate functionality by experimentally evaluating its workspace, and discuss possible paths for future development.

8 July 2022 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
ACAngus B. Clark
Angus B. Clark
NRNicolas Rojas
Nicolas Rojas
Through the implementation of reconfigurability to achieve flexibility and adaptation to tasks by morphology changes rather than by increasing the number of joints, malleable robots present advantages over traditional serial robot arms in regards to reduced weight, size, and cost. While limited in degrees of freedom (DOF), malleable robots still provide versatility across operations typically served by systems using higher DOF than required by the tasks. In this article, we present the creation of a 2-DOF malleable robot, detailing the design of joints and malleable link, along with its modeling through forward and inverse kinematics, and a reconfiguration methodology that informs morphology changes based on end effector location—determining how the user should reshape the robot to enable a task previously unattainable. The recalibration and motion planning for making robot motion possible after reconfiguration are also discussed, and thorough experiments with the prototype to evaluate accuracy and reliability of the system are presented. Results validate the approach and pave the way for further research in the area.