Mohammed Galal El-Gendy

Dr. Mohammed Galal El-Gendy

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2016 in Journal of Composites for Construction
Verified
Journal Article
Closed access
MEMohammed Galal El-Gendy
Mohammed Galal El-Gendy
Ehab F El-SalakawyEhab F El-Salakawy
Ehab F El-Salakawy
This paper presents test results of six full-scale glass fiber-reinforced polymer (GFRP) reinforced concrete slab–column edge connections. The test connections included two series with three connections each. The connections of Series 1 investigated the effect of a new type of GFRP shear reinforcement on the punching shear behavior of slab-column edge connections, while those of Series 2 investigated the effect of moment-to-shear ratio. For Series 1, one connection did not have shear reinforcement, while the other two connections had ribbed-deformed GFRP shear studs with headed ends at different radial spacing (120 and 80 mm). For Series 2, three different moment-to-shear ratios were applied to the connections (0.2, 0.4, and 0.6 m). The typical dimensions of the slabs were 2,800×1,550×200 mm with a 300-mm square column extending above and below the slab. The headed ends of the studs provided adequate anchorage, which allowed the studs to control the propagation of shear cracks and to increase the...

1 April 2020 in Journal of Composites for Construction
Verified
Journal Article
Closed access
MEMohammed Galal El-Gendy
Mohammed Galal El-Gendy
EEEhab F. El-Salakawy
Ehab F. El-Salakawy
In regions of high seismic activity, flat plate systems can be used as gravity force resisting systems, where special moment frames are provided as seismic force resisting systems. Nevertheless, all elements of the reinforced concrete (RC) structure must have sufficient deformability to be capable of deforming into the inelastic range. An efficient method of enhancing the deformability of flat plate systems is providing slab shear reinforcement. This paper presents the results of an experimental program evaluating the efficiency of two new types of glass fiber-reinforced polymer (GFRP) shear reinforcement in enhancing the deformability of GFRP-RC slab-column edge connections. Three full-scale connections were tested under gravity and uniaxial reversed-cyclic lateral loading, one connection was reinforced with GFRP shear studs, one with GFRP corrugated bars, and one had no shear reinforcement. The use of GFRP shear studs and corrugated bars increased the lateral load capacity of the connections by 47% and 44%, respectively. In addition, both types of GFRP shear reinforcement were able to enhance the deformability of the connections significantly, whereas the connection with shear studs was able to sustain deformations associated with 3.50% drift ratio without jeopardizing its gravity load capacity.

1 October 2020 in Journal of Composites for Construction
Verified
Journal Article
Closed access
PDF file
MEMohammed Galal El-Gendy
Mohammed Galal El-Gendy
Ehab F El-SalakawyEhab F El-Salakawy
Ehab F El-Salakawy
Several empirical models have been introduced during the last two decades to estimate the punching capacity of two-way slabs reinforced with fiber-reinforced polymer (FRP) reinforcement. In this study, the applicability of these models on FRP-reinforced concrete (RC) slab-column interior and edge connections subjected to gravity loads is assessed. The models are also calibrated against experiments conducted previously by the authors on FRP-RC edge connections subjected to reversed-cyclic lateral loads. Test results of 68 interior and 25 edge specimens, 6 of which were tested under reversed-cyclic lateral loads, were used to evaluate the available models. Based on the analysis, a universal model capable of accurately predicting the capacity of both interior and edge specimens subjected to gravity or cyclic loads is proposed. The proposed model provided a mean test-to-predicted strength of 1.01 ± 0.14 and 1.01 ± 0.09 for interior and edge specimens, respectively. Furthermore, a design model is proposed to estimate gravity shear limits for FRP-RC connections without shear reinforcement and subjected to cyclic load.

1 February 2021 in Journal of Composites for Construction
Verified
Journal Article
Closed access
PDF file
MEMohammed Galal El-Gendy
Mohammed Galal El-Gendy
Ehab F El-SalakawyEhab F El-Salakawy
Ehab F El-Salakawy
A series of finite-element analyses for slab­–column edge connections reinforced with fiber-reinforced polymer (FRP) reinforcement and subjected to reversed-cyclic lateral load is conducted and discussed. A three-dimensional nonlinear finite-element model (FEM) is constructed using a commercially available software. The FEM is validated against the results of experimental studies conducted previously by the authors. Subsequently, the validated FEM is used to carry out an extensive parametric study investigating the influence of key parameters including the gravity shear ratio (0.2–0.8), flexural reinforcement type [glass and carbon FRP (GFRP and CFRP, respectively)], column aspect ratio (0.25–4.00), flexural reinforcement ratio (0.7%–1.4%), and slab thickness (150–400 mm). The results showed that the drift capacity of edge connections reinforced with either GFRP or CFRP reinforcement is reduced when the applied gravity shear ratio increases. However, GFRP-reinforced concrete (RC) connections were able to undergo larger drift ratios than their CFRP-RC counterparts. In addition, increasing the slab thickness reduced the punching shear strength of GFRP-RC connections, even for slabs with an effective depth less than 300 mm.

1 April 2021 in Journal of Bridge Engineering
Verified
Journal Article
Closed access
PDF file
SLShady Nasry Badie Labib
Shady Nasry Badie Labib
MEMohammed Galal El-Gendy
Mohammed Galal El-Gendy
Ehab F El-SalakawyEhab F El-Salakawy
Ehab F El-Salakawy
In this study, a new transverse post-tensioning (TPT) technique for box girder bridges is investigated, where TPT is applied at the top flange of the girder resulting in eliminating the intermediate transverse diaphragms. A one-third-scale bridge model consisting of four adjacent box girders with partial-depth shear keys was erected and tested. The bridge model was investigated for the optimal TPT force and spacing to ensure a uniform distribution of the clamping prestress. The efficiency of the proposed technique in transversely distributing live loads during simulated service and ultimate conditions was also investigated. Test results demonstrated that distributing the TPT force at a shorter spacing along the length of the bridge is more efficient than increasing the TPT force at discrete distant locations in producing the minimum required concrete prestress. It was observed that the effect of TPT force and spacing was insignificant during the simulated service condition, where shear keys remained intact or partially cracked. However, at failure, the presence of TPT added redundancy to the bridge model and mitigated any sudden failure when shear keys were fully cracked.

1 October 2021 in Journal of Composites for Construction
Verified
Journal Article
Closed access
PDF file
MEMohammed Galal El-Gendy
Mohammed Galal El-Gendy
Ehab F El-SalakawyEhab F El-Salakawy
Ehab F El-Salakawy
When reinforced concrete (RC) slabs are supported directly on columns, a combination of shear forces and unbalanced bending moments is transferred between the slab and the columns at slab–column connections. The unbalanced moment transferred between a slab and a column can be significantly increased by the application of horizontal loads, such as wind and seismic loads. According to current design codes and standards for steel–RC structures in North America, a portion of the unbalanced moment is assumed to be transferred by the eccentricity of shear, while the remaining portion is assumed to be transferred by flexure. Previous research shows that the slab width that contributes to transferring the flexure portion is bounded by lines located at a distance of 1.5 times the slab thickness on each side of the column. This study investigates whether the same slab width can be used to transfer the unbalanced moments in slab–column connections reinforced with glass fiber–reinforced polymer (GFRP) reinforcement. A similar approach to that used for steel–RC connections is followed to analyze data from 27 GFRP-RC connections without shear reinforcement reported in the literature. Furthermore, a previously validated finite-element model is used to investigate the strain distribution in the longitudinal slab reinforcement along the transverse direction of the slab. The results show that a smaller slab width bounded by lines located at a distance of 0.5 times the slab thickness on each side of the column is recommended for GFRP-RC slabs.