Lawson David Gillespie

Mr. Lawson David Gillespie

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2024 in Environmental Science & Technology
Verified
Journal Article
Open access
FVFelix Vogel
Felix Vogel
SAS. Ars
S. Ars
DWD. Wunch
D. Wunch
JLJ. Lavoie
J. Lavoie
LGLawson David Gillespie
Lawson David Gillespie
ACA. Calcan
A. Calcan
To mitigate methane emission from urban natural gas distribution systems, it is crucial to understand local leak rates and occurrence rates. To explore urban methane emissions in cities outside the U.S., where significant emissions were found previously, mobile measurements were performed in 12 cities across eight countries. The surveyed cities range from medium size, like Groningen, NL, to large size, like Toronto, CA, and London, UK. Furthermore, this survey spanned across European regions from Barcelona, ES, to Bucharest, RO. The joint analysis of all data allows us to focus on general emission behavior for cities with different infrastructure and environmental conditions. We find that all cities have a spectrum of small, medium, and large methane sources in their domain. The emission rates found follow a heavy-tailed distribution, and the top 10% of emitters account for 60-80% of total emissions, which implies that strategic repair planning could help reduce emissions quickly. Furthermore, we compare our findings with inventory estimates for urban natural gas-related methane emissions from this sector in Europe. While cities with larger reported emissions were found to generally also have larger observed emissions, we find clear discrepancies between observation-based and inventory-based emission estimates for our 12 cities.

5 June 2024 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
BHBenedikt Herkommer
Benedikt Herkommer
CACarlos Alberti
Carlos Alberti
PCPaolo Castracane
Paolo Castracane
JCJia Chen
Jia Chen
ADAngelika Dehn
Angelika Dehn
DWDebra Wunch
Debra Wunch
To fight climate change, it is crucial to have a precise knowledge of greenhouse gas (GHG) concentrations in the atmosphere and to monitor sources and sinks of GHGs. On global scales, satellites are an appropriate monitoring tool. For the validation of the satellite measurements and to tie them to the World Meteorological Organization (WMO) trace gas scale, ground-based Fourier transform infrared (FTIR) networks are used, which provide reference data. To ensure the highest-quality validation data, the network must be scaled to the WMO trace gas scale and have a very small site-to-site bias. Currently, the Total Carbon Column Observing Network (TCCON) is the de facto standard FTIR network for providing reference data. Ensuring a small site-to-site bias is a major challenge for the TCCON. In this work, we describe the development and application of a new method to evaluate the site-to-site bias by using a remotely controlled portable FTIR spectrometer as a travel standard (TS) for evaluating the consistency of columnar GHG measurements performed at different TCCON stations, and we describe campaign results for the TCCON sites in Tsukuba (Japan), East Trout Lake (Canada) and Wollongong (Australia). The TS is based on a characterized portable EM27/SUN FTIR spectrometer equipped with an accurate pressure sensor which is operated in an automated enclosure. The EM27/SUN is the standard instrument of the Collaborative Carbon Column Observing Network (COCCON). The COCCON is designed such that all spectrometers are referenced to a common reference unit located in Karlsruhe, Germany. To evaluate the long-term stability of the TS instrument, it is placed side-by-side with the TCCON instrument in Karlsruhe (KA) and the COCCON reference unit (the EM27/SUN spectrometer SN37, which is operated permanently next to the TCCON-KA site) between deployments to collect comparing measurements. At each of the visited TCCON sites, the TCCON spectrometers collected low-resolution (LR) (0.5 cm−1) and high-resolution (HR) (0.02 cm−1) measurements in an alternating manner. Based on the TS as a portable standard, the measurements are compared to the Karlsruhe site as a common reference. For Tsukuba and Wollongong, the agreement with the reference in Karlsruhe found for XCO2 is on the 0.1 % level for both the LR and HR measurements. For XCH4, the agreement is at the 0.2 % level, with the low-resolution measurements showing a low bias at both sites and for both gases. For XCO, the deviations are up to 7 %. The reason for this is likely to be a known issue with the CO a priori profiles used by the TCCON over source regions. In East Trout Lake (ETL), the TCCON spectrometer broke down while the TS was en route to the station. Hence, no side-by-side comparison was possible there. An important auxiliary value for FTIR retrievals is the surface pressure. Using the pressure sensor in the TS, the surface pressure measurements at each site are also compared. The surface pressure analysis reveals excellent agreement (0.027, 0.135 and 0.094 hPa) for the Tsukuba, ETL and Wollongong sites.

3 March 2025 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
VFVictoria A. Flood
Victoria A. Flood
KSKimberly Strong
Kimberly Strong
CWCynthia H. Whaley
Cynthia H. Whaley
JCJack Chen
Jack Chen
DWDebra Wunch
Debra Wunch
NPNasrin Mostafavi Pak
Nasrin Mostafavi Pak
The record‐breaking 2023 Canadian wildfire season had large‐scale burning that resulted in wide‐reaching long‐range transport of smoke plumes and their associated trace gases. This paper examines three events (May 16‐23, June 3‐9 and June 17‐30, 2023) during which the composition of smoke was measured over Toronto and Egbert, Ontario. Tropospheric columns (0–10 km) of CO, C2H6, CH3OH, HCN, HCOOH, NH3 and O3 were measured using high‐resolution Fourier transform infrared spectrometers. Coincident enhancements of CO and other gases during the events were used to calculate enhancement ratios. Correlations with CO were observed for C2H6, CH3OH, HCN and HCOOH, but not for NH3 and O3. Plume transport was investigated with the Hybrid Single‐Particle Lagrangian Integrated Trajectory model, the GEM‐MACH‐FireWork (GM‐FW) air quality model, and Measurements of Pollution in the Troposphere (MOPITT) CO satellite data. Additional measurements examined were surface CO, O3, and PM2.5, plume height from a Mini Micro Pulse Lidar, and EM27/SUN XCO columns. GM‐FW model output was compared with ground‐based surface and 0–10 km column measurements, and MOPITT CO maps. Over the 2023 forest fire season (May‐September), the model underestimated background tropospheric columns of CO, NH3 and O3, but generally overestimated enhancements during smoke events. Relative to surface in situ measurements, GM‐FW seasonal averages overestimated CO and underestimated O3 (which was not generally enhanced during smoke events), while PM2.5 fluctuated between a positive and negative bias. Compared to MOPITT, the GM‐FW event‐averaged CO columns appropriately represent plume dispersion across the country, with some offsets on the scale of the ground‐based locations that are consistent with the discussed findings.

9 January 2025 in Journal of the Air & Waste Management Association
Verified
Journal Article
Open access
LGLawson David Gillespie
Lawson David Gillespie
SASébastien Ars
Sébastien Ars
SASamantha Alkadri
Samantha Alkadri
SUSiyar Urya
Siyar Urya
TKTimothy Khoo
Timothy Khoo
DWDebra Wunch
Debra Wunch
We estimate methane emissions rates for urban waste treatment facilities from mobile in situ atmospheric concentration measurements using an inverse Gaussian plume methodology at facilities in Southern Ontario, Canada. We use these estimated emissions rates to investigate, update, and improve the existing high resolution methane inventories at the facility level for waste sources throughout the Greater Toronto Area and Southwestern Ontario. Our measurements encompass tens of thousands of kilometers worth of mobile survey data collected over 7 years, encompassing more than 650 downwind transects where we surveyed 14 active landfills, 11 closed landfills, 2 organic waste processing facilities, 3 open air windrow compost facilities, and 11 water resource recovery facilities across our study region. These sources account for 77% of the active landfills within Southern Ontario, which is estimated in inventories to be the largest source of methane emissions in the region. Within the Greater Toronto Area (GTA) megacity, the measured facilities represent about 52% of the total inventoried non-wetland methane emissions. We find that emissions from closed landfills are lower than inventory estimates, with significant implications for the methane budget in the GTA. We update the Facility Level and Area Methane Emissions for the GTA inventory with our measured emissions rates, which results in a 54% decline in the solid waste emissions, effecting a 35% lower estimate for the total anthropogenic methane emissions in the region. We attribute the bulk of this difference to a single facility: the Keele Valley landfill. Our atmospheric measurements also serve as a novel metric for evaluating the discrepancies between four facility level, and two high resolution gridded methane emissions inventories. Based on linear regressions of our measured emissions versus inventoried values, we find that the facility level first order decay model maintained by Environment and Climate Change Canada (ECCC) to be the most consistent with our measured emissions rates at landfills and the self-reported emissions to the Greenhouse Gas Reporting Program of ECCC to be the least consistent with our measurements.

31 July 2025 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
JTJudith Tettenborn
Judith Tettenborn
DZDaniel Zavala-Araiza
Daniel Zavala-Araiza
DSDaan Stroeken
Daan Stroeken
HMHossein Maazallahi
Hossein Maazallahi
CVCarina van der Veen
Carina van der Veen
TRThomas Röckmann
Thomas Röckmann
Mobile real-time measurements of ambient methane provide a fast and effective method to identify and quantify methane leaks from local gas distribution systems in urban areas. The objectives of these methodologies are to (i) identify leak locations for repair and (ii) construct measurement-based emission rate estimates, which can improve emissions reporting and contribute to monitoring emission changes over time. Currently, the most common method for emission quantification uses the maximum methane enhancement detected while crossing a methane plume. However, the recorded maximum depends on instrument characteristics, such as measurement cell size, pump speed, and measurement frequency. Consequently, the current approach can only be used by instruments with similar characteristics. We suggest that the integrated spatial peak area is a more suitable quantity that can eliminate the bias between different instruments. Based on controlled release experiments conducted with various devices in four cities (London, Toronto, Rotterdam, and Utrecht), emission estimation methodologies were evaluated. Indeed, when different analysers were measuring in the same vehicle and from the same air inlet, the integrated spatial peak area was found to be a more robust metric across different methane gas analyser devices than the maximum methane enhancement. A statistical function based on integrated spatial peak area is proposed for more consistent emission estimations when using different instruments. On top of this systematic relation between actual emission rate and recorded spatial peak area, large variations in methane spatial peak area were observed for the multiple transects across the same release point, in line with previous experiments. This variability is the main contributor to uncertainty in efforts to use mobile measurements to prioritize leak repair. We show that repeated transects can reduce this uncertainty and improve the categorization into different leak categories. We recommend a minimum of three and an optimal range of five–seven plume transects for effective emission quantification to prioritize repair actions.

20 August 2025 in Environmental Research Communications
Verified
Journal Article
Open access
RMRegina Gonzalez Moguel
Regina Gonzalez Moguel
JAJacob Asomaning
Jacob Asomaning
EREmilie Reid
Emilie Reid
DRDjordje Romanic
Djordje Romanic
FVFelix Vogel
Felix Vogel
YHYi Huang
Yi Huang
Urban centers contribute significantly to anthropogenic methane (CH4) emissions, making them key targets for mitigation. This study aimed to map the spatial distribution of CH4 hotspots in Montreal, Canada, identify potential sources, and quantify emissions from key sectors. In over four years, we surveyed over 3,300 km with our mobile monitoring system and detected 3,045 CH4 hotspots, defined as mole fractions exceeding a baseline. Most hotspots were smaller than 1 ppm (85%), while larger hotspots (>1 ppm) were linked to landfills. Three routes were surveyed 10 times each, and within this subset of hotspots, most (89%) were observed only once. Among all detected hotspots, 487 were classified as leak indications, defined as hotspots with narrow widths (<160 m) and distant from known CH4 sources. Leak indications occurred more frequently in densely populated neighborhoods (R² = 0.48, p = 5.22×10⁻⁶), with an estimated emission rate of 250–507 kg day⁻¹. Emissions from four major landfills, calculated through a Gaussian plume inversion, were estimated at 10,064–36,410 kg CH₄ day⁻¹, with historical landfills alone contributing 6,641–18,467 kg CH₄ day⁻¹. These findings confirm the dominant role of landfills to Montreal CH4 emissions and highlight the importance of targeting waste management sites for urban methane mitigation.