Philip Logan Handley

Mr. Philip Logan Handley

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
NKNatalie Kille
Natalie Kille
SBSunil Baidar
Sunil Baidar
PHPhilip Logan Handley
Philip Logan Handley
IOIvan Ortega
Ivan Ortega
RSRoman Sinreich
Roman Sinreich
RVRainer Volkamer
Rainer Volkamer
We describe the University of Colorado mobile Solar Occultation Flux instrument (CU mobile SOF). The instrument consists of a digital mobile solar tracker that is coupled to a Fourier transform spectrometer (FTS) of 0.5 cm−1 resolution and a UV–visible spectrometer (UV–vis) of 0.55 nm resolution. The instrument is used to simultaneously measure the absorption of ammonia (NH3), ethane (C2H6) and nitrogen dioxide (NO2) along the direct solar beam from a moving laboratory. These direct-sun observations provide high photon flux and enable measurements of vertical column densities (VCDs) with geometric air mass factors, high temporal resolution of 2 s and spatial resolution of 5–19 m. It is shown that the instrument line shape (ILS) of the FTS is independent of the azimuth and elevation angle pointing of the solar tracker. Further, collocated measurements next to a high-resolution FTS at the National Center for Atmospheric Research (HR-NCAR-FTS) show that the CU mobile SOF measurements of NH3 and C2H6 are precise and accurate; the VCD error at high signal to noise ratio is 2–7 %. During the Front Range Air Pollution and Photochemistry Experiment (FRAPPE) from 21 July to 3 September 2014 in Colorado, the CU mobile SOF instrument measured median (minimum, maximum) VCDs of 4.3 (0.5, 45) × 1016 molecules cm−2 NH3, 0.30 (0.06, 2.23) × 1016 molecules cm−2 NO2 and 3.5 (1.5, 7.7) × 1016 molecules cm−2 C2H6. All gases were detected in larger 95 % of the spectra recorded in urban, semi-polluted rural and remote rural areas of the Colorado Front Range. We calculate structure functions based on VCDs, which describe the variability of a gas column over distance, and find the largest variability for NH3. The structure functions suggest that currently available satellites resolve about 10 % of the observed NH3 and NO2 VCD variability in the study area. We further quantify the trace gas emission fluxes of NH3 and C2H6 and production rates of NO2 from concentrated animal feeding operations (CAFO) using the mass balance method, i.e., the closed-loop vector integral of the VCD times wind speed along the drive track. Excellent reproducibility is found for NH3 fluxes and also, to a lesser extent, NO2 production rates on 2 consecutive days; for C2H6 the fluxes are affected by variable upwind conditions. Average emission factors were 12.0 and 11.4 gNH3 h−1 head−1 at 30 °C for feedlots with a combined capacity for ∼ 54 000 cattle and a dairy farm of ∼ 7400 cattle; the pooled rate of 11.8 ± 2.0 gNH3 h−1 head−1 is compatible with the upper range of literature values. At this emission rate the NH3 source from cattle in Weld County, CO (535 766 cattle), could be underestimated by a factor of 2–10. CAFO soils are found to be a significant source of NOx. The NOx source accounts for ∼ 1.2 % of the N flux in NH3 and has the potential to add ∼ 10 % to the overall NOx emissions in Weld County and double the NOx source in remote areas. This potential of CAFO to influence ambient NOx concentrations on the regional scale is relevant because O3 formation is NOx sensitive in the Colorado Front Range. Emissions of NH3 and NOx are relevant for the photochemical O3 and secondary aerosol formation.

1 January 2019 in Elementa: Science of the Anthropocene
Verified
Journal Article
Open access
PDF file
IMIngrid Mielke-Maday
Ingrid Mielke-Maday
SSStefan Schwietzke
Stefan Schwietzke
TYTara Irene Yacovitch
Tara Irene Yacovitch
BMBenjamin Miller
Benjamin Miller
SCSteve Conley
Steve Conley
GPGabrielle Pétron
Gabrielle Pétron
An intensive coordinated airborne and ground-based measurement study was conducted in the Fayetteville Shale in northwestern Arkansas during September and October 2015 to compare and explain potential discrepancies between top-down and bottom-up estimates of regional natural gas (NG) methane (CH4) emissions. In situ mobile downwind measurements are used to document the ethane to methane enhancement ratios (ERs) in emission plumes from NG operations in the region. Enhancement ratios are low (<2% for 87% of NG sources sampled) in this dry gas-producing region and normally distributed around 1.3% in the western half of the study area. A few sampled landfills emitted CH4 but no ethane (C2H6). Sampling drives around large chicken farms, prevalent in the region, did not detect significant downwind CH4 enhancements. In situ airborne measurements of C2H6 and CH4 from area-scale surveys over and downwind of the region documented the resulting ERs from a mix of CH4 sources. Based on these measurements, we show that on average during the measurement windows 85–95% of total CH4 emissions in the western half of the Fayetteville Shale originated from NG sources, which agrees well with bottom-up estimates from the same field study. Lower mixing ratios measured over the eastern half of the region did not support the ER analysis due to the low signal-to-noise on C2H6 measurements.

20 February 2025 in Remote Sensing
Verified
Journal Article
Open access
PDF file
MSMahesh Kumar Sha
Mahesh Kumar Sha
SDSaswati Das
Saswati Das
MFMatthias Max Frey
Matthias Max Frey
DDDarko Dubravica
Darko Dubravica
CACarlos Alberti
Carlos Alberti
MZMinqiang Zhou
Minqiang Zhou
The COllaborative Carbon Column Observing Network has become a reliable source of high-quality ground-based remote sensing network data that provide column-averaged dry-air mole fractions of carbon dioxide (XCO2), methane (XCH4), and carbon monoxide (XCO). The fiducial reference measurements of these gases from the COCCON complement the TCCON and NDACC-IRWG data. This study shows the application of COCCON data for the validation of existing greenhouse gas satellite products. This study includes the validation of XCH4 and XCO products from the European Copernicus Sentinel-5 Precursor (S5P) mission, XCO2 products from the American Orbiting Carbon Observatory-2 (OCO-2) mission, and XCO2 and XCH4 products from the Japanese Greenhouse gases Observing SATellite (GOSAT). A total of 27 datasets contributed to this study; some of these were collected in the framework of campaign activities and covered only a short time period. In addition, several permanent stations provided long-term observations. The random uncertainties in the validation results, specifically for S5P with a lot of coincidences pairs, are found to be similar to the comparison with the TCCON. The comparison results of OCO-2 land nadir and land glint observation modes to the COCCON on a global scale, despite limited coincidences, are very promising. The stations can, therefore, expand on the coverage of the already existing ground-based reference remote sensing sites from the TCCON and the NDACC network. The COCCON data can be used for future satellite and model validation studies and carbon cycle studies.

17 November 2025 in Environmental Science & Technology
Verified
Journal Article
Closed access
FPFabien Paulot
Fabien Paulot
GPGabrielle Pétron
Gabrielle Pétron
ACAndrew Crotwell
Andrew Crotwell
MCMolly Crotwell
Molly Crotwell
PHPhilip Logan Handley
Philip Logan Handley
AAArlyn Andrews
Arlyn Andrews

14 November 2025
Verified
Other
Open access
PDF file
YLYunsong Liu
Yunsong Liu
NMNatasha Miles
Natasha Miles
SRScott James Richardson
Scott James Richardson
ZBZachary Robert Barkley
Zachary Robert Barkley
DMDavid Owen Miller
David Owen Miller
KDKenneth James Davis
Kenneth James Davis
Concurrent measurements of methane (CH4) and ethane (C2H6) can be used to identify and separate methane sources, as ethane is present in thermogenic sources (e.g., oil and natural gas) but not in biogenic sources (e.g., agriculture). In this study, we evaluated the performance of multiple Aeris MIRA Ultra instruments (Versions 1 and 2) through controlled laboratory tests and tower-based deployments under field conditions. The systems were modified with an external pump, flow control, a Nafion dryer, and a custom-built auxiliary box to automate the system and transmit near real-time data. We determined the best calibration approach for our application, given practical limitations, to be a full calibration cycle (with ambient and high calibration cylinders) about once per day and an ambient calibration cylinder sampled hourly. Measurement uncertainty was assessed, including the uncertainty due to instrument noise as a function of calibration frequency, uncertainty in the water vapor correction, and cylinder assignment uncertainty. Instrument noise was the dominant source of uncertainty for C2H6, while the water vapor correction dominated the CH4 uncertainty. For Version 2 systems with hourly calibrations and a Nafion dryer with counterflow, the mean total uncertainty, including both systematic errors and noise, of hourly averages was 0.8–3.0 ppb CH4 and 0.35–0.37 ppb C2H6. Laboratory intercomparisons showed network compatibility within 1.2 ppb CH4 and 0.23 ppb C2H6, and a collocated deployment with a NOAA Picarro system agreed within 1.8 ppb CH4. Instrument noise varied substantially amongst the instruments, with errors reaching up to 11 ppb CH4 and 2 ppb C2H6 for hourly means, with similar variability indicated in a 50-h cylinder test. With appropriate engineering and calibration, the Aeris MIRAUltra shows the capability to measure ethane and methane with sufficient stability to distinguish regional methane emission sources in many field settings.

3 January 2026
Verified
Other
Open access
PDF file
YLYunsong Liu
Yunsong Liu
NMNatasha Miles
Natasha Miles
SRScott James Richardson
Scott James Richardson
ZBZachary Robert Barkley
Zachary Robert Barkley
DMDavid Owen Miller
David Owen Miller
KDKenneth James Davis
Kenneth James Davis
Concurrent measurements of methane (CH4) and ethane (C2H6) can be used to identify and separate methane sources, as ethane is present in thermogenic sources (e.g., oil and natural gas) but not in biogenic sources (e.g., agriculture). In this study, we evaluated the performance of multiple Aeris MIRA Ultra instruments (Versions 1 and 2) through controlled laboratory tests and tower-based deployments under field conditions. The systems were modified with an external pump, flow control, a Nafion dryer, and a custom-built auxiliary box to automate the system and transmit near real-time data. We determined the best calibration approach for our application, given practical limitations, to be a full calibration cycle (with ambient and high calibration cylinders) about once per day and an ambient calibration cylinder sampled hourly. Measurement uncertainty was assessed, including the uncertainty due to instrument noise as a function of calibration frequency, uncertainty in the water vapor correction, and cylinder assignment uncertainty. Instrument noise was the dominant source of uncertainty for C2H6, while the water vapor correction dominated the CH4 uncertainty. For Version 2 systems with hourly calibrations and a Nafion dryer with counterflow, the mean total uncertainty, including both systematic errors and noise, of hourly averages was 0.8–3.0 ppb CH4 and 0.35–0.37 ppb C2H6. Laboratory intercomparisons showed network compatibility within 1.2 ppb CH4 and 0.23 ppb C2H6, and a collocated deployment with a NOAA Picarro system agreed within 1.8 ppb CH4. Instrument noise varied substantially amongst the instruments, with errors reaching up to 11 ppb CH4 and 2 ppb C2H6 for hourly means, with similar variability indicated in a 50-h cylinder test. With appropriate engineering and calibration, the Aeris MIRAUltra shows the capability to measure ethane and methane with sufficient stability to distinguish regional methane emission sources in many field settings.