Edgar Vicente Macías-Melo

Dr. Edgar Vicente Macías-Melo


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
MRMaría Magdalena Villar Ramos
María Magdalena Villar Ramos
Iván Hernández-PérezIván Hernández-Pérez
Iván Hernández-Pérez
KCKarla María Aguilar Castro
Karla María Aguilar Castro
IZIvett Zavala-Guillén
Ivett Zavala-Guillén
EMEdgar Vicente Macías-Melo
Edgar Vicente Macías-Melo
Juan Serrano-ArellanoJuan Serrano-Arellano
Juan Serrano-Arellano
Among the alternatives for improving the thermal comfort conditions inside buildings are the thermally activated building systems (TABS). They are embedded in different building components to improve the indoor air temperature. In this work, a review and analysis of the state of the art of TABS was carried out to identify their potential to improve thermal comfort conditions and provide energy savings. Furthermore, this study presents the gaps identified in the literature so that researchers can develop future studies on TABS. The articles found were classified and analyzed in four sections, considering their implementation in roofs, walls, floors, and the whole envelope. In addition, aspects related to the configuration of the TABS and the fluid (speed, temperature, and mass flow rate) were analyzed. It was found that when TABS are implemented in roofs, walls, and floors, a reduction in the indoor temperature of a building of up to 14.4 °C can be obtained. Within the limitations of the TABS, the complexity and costs of their implementation compared to the use of air conditioning systems are reported. However, the TABS can provide energy savings of up to 50%.

8 January 2020 in Energies
Verified
Journal Article
Open access
PDF file
HDHeidi Paola Díaz-Hernández
Heidi Paola Díaz-Hernández
PTPablo René Torres-Hernández
Pablo René Torres-Hernández
KCKarla María Aguilar Castro
Karla María Aguilar Castro
EMEdgar Vicente Macías-Melo
Edgar Vicente Macías-Melo
MJMaría José Jiménez
María José Jiménez
This paper reports the application of RC dynamic models (network of resistances and capacitances analogous to electrical networks) to obtain the heat loss coefficient (HLC) from a dynamic test campaign carried out in an in-use building. It is a well-insulated building located in Gainsborough, U.K. This case study and data were made available to participants in the IEA–EBC Annex 71 project Building Energy Performance Assessment Based on In-Situ Measurements. The analysis reported in this paper is mainly focused on the identification of the main heat transfer contributions and also on the translation of these phenomena to the RC models used to obtain the required HLC. First pre-processing and qualitative analysis were carried out. Afterwards several candidate models were constructed according to different plausible assumptions and approximations. The validity of the results obtained using these models has been evaluated taking into account the agreement among different data series and also the levels of the residuals obtained using the different models. The work concludes obtaining accurate estimates of the HLC from the energy balance including the following relevant contributions: space heating, solar gains, internal gains due to appliances, and internal gains due to metabolic activity. These terms were modelled using the following driving variables: consumption of gas and water, electricity production by the photovoltaic (PV) panels and electricity consumption (modelling internal gains due to appliances and occupancy patterns).

18 November 2018 in Energies
Verified
Journal Article
Open access
PDF file
LMLuis Manuel Lopez Manrique
Luis Manuel Lopez Manrique
EMEdgar Vicente Macías-Melo
Edgar Vicente Macías-Melo
Oscar May TzucOscar May Tzuc
Oscar May Tzuc
Bassam AliBassam Ali
Bassam Ali
KCKarla María Aguilar Castro
Karla María Aguilar Castro
Iván Hernández-PérezIván Hernández-Pérez
Iván Hernández-Pérez
This work studies the characteristics of the wind resource for a location in the north zone of Tehuantepec isthmus. The study was conducted using climatic data from Cuauhtemotzin, Mexico, measured at different altitudes above the ground level. The measured data allowed establishing the profile of wind speeds as well as the analysis of its availability. Analysis results conclude that the behavior of the wind speed presents a bimodal distribution with dominant northeast wind direction (wind flow of sea–land). In addition, the area was identified as feasible for the use of low speed power wind turbines. On the other hand, the application of a new approach for very short-term wind speed forecast (10 min) applying multi-gene genetic programming and global sensitivity analysis is also presented. Using a computational methodology, an exogenous time series with fast computation time and good accuracy was developed for the forecast of the wind speed. The results presented in this work complement the panorama for the evaluation of the resource in an area recognized worldwide for its vast potential for wind power.

20 October 2022 in Journal of Building Physics
Verified
Journal Article
Closed access
CACarlos Enrique Torres Aguilar
Carlos Enrique Torres Aguilar
JAJ Arce
J Arce
JXJ Xamán
J Xamán
EMEdgar Vicente Macías-Melo
Edgar Vicente Macías-Melo
Solar chimneys provide natural ventilation for buildings, reducing the energy consumption of mechanical systems. Therefore, analyzing energy losses through solar chimney components and inlet/outlet of air channel is critical to develop a suitable design for this passive ventilation system. In this study, the performance and energy losses analysis of a single-channel solar chimney (SC-SOCH) is described; a parametric study under laboratory conditions was conducted regarding the air gap (0.10, 0.15, and 0.20 m) and heat flux of absorber plate (100, 200, 300, 400, and 500 Wm−2). The energy losses were analyzed with temperature sensors, heat flow transducers, and a net radiation transfer model. The parametric study results showed that between 10% and 15% of the total energy supplied to the absorber plate was dissipated to the laboratory environment through the glass cover. Furthermore, combining the different thermal insulation layers on the backside of the absorber plate and sidewalls of the air channel permitted only energy losses below 8% of the total energy supplied. The highest energy losses occurred due to radiative exchange; the radiative losses through the inlet and outlet of the air channel were between 9.38% and 25.78% of the total energy supplied. However, the radiative energy loss rate decreased as airflow increased; the volumetric flow rate was from 34.11 to 94.92 m3h−1, which was enough to satisfy the requirements of total ventilation rate for spaces of 9, 18, and 36 m2 according to ASHRAE 62.2–2019. Therefore, solar chimney designs must be optimized to minimize energy losses and increase airflow for natural ventilation.

11 December 2019 in Energy & Environment
Verified
Journal Article
Closed access
PDF file
LMLuis Manuel Lopez Manrique
Luis Manuel Lopez Manrique
EMEdgar Vicente Macías-Melo
Edgar Vicente Macías-Melo
KAKm Aguilar-Castro
Km Aguilar-Castro
Iván Hernández-PérezIván Hernández-Pérez
Iván Hernández-Pérez
HDHp Díaz-Hernández
Hp Díaz-Hernández
In this study, we present a review of articles that address the state of the art in wind energy from different perspectives, specifically focusing on the criteria used for wind energy assessment and wind turbine standards, along with an overview of the technologies necessary to make reliable Wind Power-Grid penetration more efficient. Wind power dynamics are also considered from the perspective of their intermittency and the nature of wind speed variability in order to establish appropriate sampling times for measurements and monitoring. The literature discussed is representative of the technological and methodological advances dedicated to the development, adaptation and application of statistical, computational, numerical and artificial intelligence tools for an assessment of wind energy and wind power forecasting. These applications and methodologies commonly use data registers measured in very short, short, medium and long-term measurement campaigns. Finally, literature on wind power social, environmental and economic policies and trends in costs-capacity-addition and their impact are reviewed from a global perspective. In light of today’s concerns with global warming, it is essential that wind energy interact steadily on the grid with experienced operators and high automatic-control technology worldwide.

15 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
Juan Serrano-ArellanoJuan Serrano-Arellano
Juan Serrano-Arellano
Juan Manuel BelmanJuan Manuel Belman
Juan Manuel Belman
JXJesús Xamán
Jesús Xamán
KCKarla María Aguilar Castro
Karla María Aguilar Castro
EMEdgar Vicente Macías-Melo
Edgar Vicente Macías-Melo
A study was conducted on the double diffusion by natural convection because of the effects of heat and pollutant sources placed at one third of the closed cavity’s height. The heat and pollution sources were analyzed separately and simultaneously. The study was considered for the Rayleigh number interval 10 4   ≤   R a   ≤   10 10 . Three case studies were analyzed: (1) differentially heated closed cavity with only heat sources; (2) differentially heated closed cavity with only pollutant sources; and (3) differentially heated closed cavity with heat and pollutant sources. The governing equations of the system were solved through the finite volume technique. The turbulence solution was done with the k-ε model. The dominant influence of the buoyancy forces was found due to the pollutant diffusion on the flow pattern, and an internal temperature increase was observed with the simple diffusion. The most critical case was obtained through the double diffusive convection with an average temperature value of 32.57 °C. Finally, the Nusselt number increased as the Rayleigh number increased; however, the Sherwood number either increased or decreased when the Rayleigh number increased. The highest mean concentration recorded was 2808 ppm; this was found with the value R a = 10 6 .