Karla María Aguilar Castro

Dr. Karla María Aguilar Castro


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
MRMaría Magdalena Villar Ramos
María Magdalena Villar Ramos
Iván Hernández-PérezIván Hernández-Pérez
Iván Hernández-Pérez
KCKarla María Aguilar Castro
Karla María Aguilar Castro
IZIvett Zavala-Guillén
Ivett Zavala-Guillén
EMEdgar Vicente Macías-Melo
Edgar Vicente Macías-Melo
Juan Serrano-ArellanoJuan Serrano-Arellano
Juan Serrano-Arellano
Among the alternatives for improving the thermal comfort conditions inside buildings are the thermally activated building systems (TABS). They are embedded in different building components to improve the indoor air temperature. In this work, a review and analysis of the state of the art of TABS was carried out to identify their potential to improve thermal comfort conditions and provide energy savings. Furthermore, this study presents the gaps identified in the literature so that researchers can develop future studies on TABS. The articles found were classified and analyzed in four sections, considering their implementation in roofs, walls, floors, and the whole envelope. In addition, aspects related to the configuration of the TABS and the fluid (speed, temperature, and mass flow rate) were analyzed. It was found that when TABS are implemented in roofs, walls, and floors, a reduction in the indoor temperature of a building of up to 14.4 °C can be obtained. Within the limitations of the TABS, the complexity and costs of their implementation compared to the use of air conditioning systems are reported. However, the TABS can provide energy savings of up to 50%.

3 August 2022 in Buildings
Verified
Journal Article
Open access
PDF file
STS. G. Mengual Torres
S. G. Mengual Torres
Oscar May TzucOscar May Tzuc
Oscar May Tzuc
KCKarla María Aguilar Castro
Karla María Aguilar Castro
MTMARGARITA TÉLLEZ
MARGARITA TÉLLEZ
JSJ. Ovando Sierra
J. Ovando Sierra
FBFrancisco Javier Barrera
Francisco Javier Barrera
This study assessed the energy-use index and carbon-footprint performance of nine medium-category Mexican hotels (two–four stars) located in tropical-climate regions. The consumption of electrical and thermal energies of each hotel was collected during audits. Based on this, various scenarios of the partial replacement of the most energy-consuming devices were evaluated and synthesized in an expert model based on artificial neural networks. The artificial-intelligence model was designed to simultaneously associate the energy-consumption indicators, environmental impact, and economic savings of hotels based on their category, location, room number, number of existing electrical or thermal devices, and their percentage of substitution with more energy-efficient technologies. The model was used to compare the various partial-technology-substitution alternatives in each hotel that could reduce energy consumption and CO2 emissions based on the current values reported by the energy-use and environmental-impact indicators. The results of the proposed approach showed that even without making total replacements of equipment such as interior and exterior lighting or air conditioners, it was possible to identify configurations that could reduce the hotels’ energy use per room-year by 9–12%. In the environmental case, using more efficient technologies could reduce environmental mitigation. The proposed methodology represents an attractive option to facilitate the analyses and the decision making of administrators according to the needs of the type of hotel to improve its performance, which also affects the reduction in operating costs.

8 January 2020 in Energies
Verified
Journal Article
Open access
PDF file
HDHeidi Paola Díaz-Hernández
Heidi Paola Díaz-Hernández
PTPablo René Torres-Hernández
Pablo René Torres-Hernández
KCKarla María Aguilar Castro
Karla María Aguilar Castro
EMEdgar Vicente Macías-Melo
Edgar Vicente Macías-Melo
MJMaría José Jiménez
María José Jiménez
This paper reports the application of RC dynamic models (network of resistances and capacitances analogous to electrical networks) to obtain the heat loss coefficient (HLC) from a dynamic test campaign carried out in an in-use building. It is a well-insulated building located in Gainsborough, U.K. This case study and data were made available to participants in the IEA–EBC Annex 71 project Building Energy Performance Assessment Based on In-Situ Measurements. The analysis reported in this paper is mainly focused on the identification of the main heat transfer contributions and also on the translation of these phenomena to the RC models used to obtain the required HLC. First pre-processing and qualitative analysis were carried out. Afterwards several candidate models were constructed according to different plausible assumptions and approximations. The validity of the results obtained using these models has been evaluated taking into account the agreement among different data series and also the levels of the residuals obtained using the different models. The work concludes obtaining accurate estimates of the HLC from the energy balance including the following relevant contributions: space heating, solar gains, internal gains due to appliances, and internal gains due to metabolic activity. These terms were modelled using the following driving variables: consumption of gas and water, electricity production by the photovoltaic (PV) panels and electricity consumption (modelling internal gains due to appliances and occupancy patterns).

18 November 2018 in Energies
Verified
Journal Article
Open access
PDF file
LMLuis Manuel Lopez Manrique
Luis Manuel Lopez Manrique
EMEdgar Vicente Macías-Melo
Edgar Vicente Macías-Melo
Oscar May TzucOscar May Tzuc
Oscar May Tzuc
Bassam AliBassam Ali
Bassam Ali
KCKarla María Aguilar Castro
Karla María Aguilar Castro
Iván Hernández-PérezIván Hernández-Pérez
Iván Hernández-Pérez
This work studies the characteristics of the wind resource for a location in the north zone of Tehuantepec isthmus. The study was conducted using climatic data from Cuauhtemotzin, Mexico, measured at different altitudes above the ground level. The measured data allowed establishing the profile of wind speeds as well as the analysis of its availability. Analysis results conclude that the behavior of the wind speed presents a bimodal distribution with dominant northeast wind direction (wind flow of sea–land). In addition, the area was identified as feasible for the use of low speed power wind turbines. On the other hand, the application of a new approach for very short-term wind speed forecast (10 min) applying multi-gene genetic programming and global sensitivity analysis is also presented. Using a computational methodology, an exogenous time series with fast computation time and good accuracy was developed for the forecast of the wind speed. The results presented in this work complement the panorama for the evaluation of the resource in an area recognized worldwide for its vast potential for wind power.

11 April 2018 in Journal of Building Physics
Verified
Journal Article
Closed access
EMEv Macias-Melo
Ev Macias-Melo
KCKarla María Aguilar Castro
Karla María Aguilar Castro
JXJ Xamán
J Xamán
Iván Hernández-PérezIván Hernández-Pérez
Iván Hernández-Pérez
This work presents the design, construction, and evaluation of a rectangular ventilated cavity. The cavity has a heated wall, a fixed air inlet port, and an air outlet port that can change in four different configurations: C-1, the outlet gap is on the upper side of the left wall; C-2, the outlet is on left of the top wall; C-3, the outlet is in the middle of the top wall; and C-4, the outlet is on right of the top wall of the cavity. The experimental tests were carried out with a heating power of 200 and 400 W. The measured indoor air temperatures in nine points, the wall surface temperatures, and heat flows are reported for validation of computer codes. Then, the numerical modeling for the ventilated cavity was done with an in-house code based on the finite volume method to show the relevance of the experimental data. From experimental result for a heating power of 400 W, the configuration C-4 presented the smallest air temperature increment of 3.3°C and the lower average indoor air temperature. In addition, configuration C-4 was more efficient to remove heat than the other configurations, with a maximum percentage of heat removed being 4.75%, 4.32%, and 2.11% more than configurations C-1, C-2, and C-3, respectively. From the validation, the maximum error was 9.9% and 11.5% for the test of 400 and 200 W, respectively. In general, most comparison points had an error smaller than 5%. From both comparisons, it can be concluded that numerical results have an acceptable quantitative approximation.

1 September 2015 in ISA Transactions
Verified
Journal Article
Closed access
EME.V. Macias-Melo
E.V. Macias-Melo
KCKarla María Aguilar Castro
Karla María Aguilar Castro
MAMayra Alvarez
Mayra Alvarez
FJFlores-Prieto Jose Jasson
Flores-Prieto Jose Jasson