Despite attempts in a number of studies to utilize muscle tissue and cells as microactuators, all of the biohybrid microdevices have been operable only in the culture medium and none have worked in air due to the dry environment. This paper demonstrates an atmospheric-operable bioactuator (AOB) fabricated by packaging an insect dorsal vessel (DV) tissue with a small amount of culture medium inside a capsule. The AOB, consisting of microtweezers and the capsule, was designed based on a structural simulation that took into account the capillary effect. The base part of the microtweezers was deformed by spontaneous contractions of the DV tissue in the medium inside the capsule, by which the front edges of the microtweezer arms projecting above the medium surface were also deformed. First, we confirmed in the medium that the DV tissue was able to reduce the gap between the arm tips of the microtweezers. After taking the AOB out of the medium, as we expected, the AOB continued to work in air at room temperature. The gap reduction in air became larger than the one in the medium due to a surface tension effect, which was consistent with the simulation findings on the surface tension by the phase-field method. Second, we demonstrated that the AOB deformed a thin-wall ring placed between its tips in air. Third, we measured the lifetime of the AOB. The AOB kept working for around 40 minutes in air, but eventually stopped due to medium evaporation. As the evaporation progressed, the microtweezers were pressed onto the capsule wall by the surface tension and opening and closing stopped. Finally, we attempted to prevent the medium from evaporating by pouring liquid paraffin (l-paraffin) over the medium after lipophilic coating of the capsule. As a result, we succeeded in prolonging the AOB lifetime to more than five days. In this study, we demonstrated the significant potential of insect muscle tissue and cells as a bioactuator in air and at room temperature. By integrating insect tissue and cells not only into a microspace but also onto a substrate, we expect to realize a biohybrid MEMS device with various functions in the near future.
Living muscle tissues and cells have been attracting attention as potential actuator candidates. In particular, insect dorsal vessel tissue (DVT) seems to be well suited for a bio-actuator since it is capable of contracting autonomously and the tissue itself and its cells are more environmentally robust under culturing conditions compared with mammalian tissues and cells. Here we demonstrate an autonomously moving polypod microrobot (PMR) powered by DVT excised from an inchworm. We fabricated a prototype of the PMR by assembling a whole DVT onto an inverted two-row micropillar array. The prototype moved autonomously at a velocity of 3.5×10−2 µm/s, and the contracting force of the whole DVT was calculated as 20 µN. Based on the results obtained by the prototype, we then designed and fabricated an actual PMR. We were able to increase the velocity significantly for the actual PMR which could move autonomously at a velocity of 3.5 µm/s. These results indicate that insect DVT has sufficient potential as the driving force for a bio-microrobot that can be utilized in microspaces.
This article describes contractile performance and controllability using different stimulation strategies of a bioactuator made from dorsal vessel (DV) tissue harvested from an insect (final stage moth larva). This insect tissue is an excellent bioactuator because of its high robustness; an accurate adjustment of culturing conditions such as temperature and pH necessary for culturing mammalian living tissues and cells is unnecessary for the DV tissue. There are no reports that measure contractile force of the DV tissue directly or measure response of the DV tissue when stimulated by different strategies systematically. To this aim, a force measurement system, which can measure contractile force directly and allows adjustment for the DV tissue length, was constructed, and the contractile properties of the DV tissue when stimulated by tensile, thermal, electrical, and chemical (crustacean cardioactive peptide [CCAP]) stimulations were evaluated with a force transducer. It was found that the tensile response could control contractile force. The thermal response could tune the contractile force and contractile frequency and there was no thermal damage up to 35°C. The electrical stimulation could control contractile force. The CCAP chemical stimulation could control contractile frequency; the CCAP effective concentration was 10−6 M. It was concluded that the contractile properties of the DV tissue could be controlled using different stimulation strategies.