Shane Fitzgerald

Dr. Shane Fitzgerald


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
DVDiana Varaden
Diana Varaden
BBBenjamin Barratt
Benjamin Barratt
MDMargaret J. Dallman
Margaret J. Dallman
ASAdam Skillern
Adam Skillern
MEMunira Suleiman Elmi
Munira Suleiman Elmi
FKFrank J. Kelly
Frank J. Kelly
The relationship between indoor air quality and public health remains under-researched. WellHome is a transdisciplinary community-based study that will engage with residents to co-design feasible and acceptable research to quantify air pollution exposure in 100 homes in West London and examine its potential to exacerbate asthma symptoms in children. Sampling strategies such as using air quality monitors and passive samplers placed in kitchens, children’s bedrooms, and living rooms, will be developed in collaboration with local ambassadors and participating households to measure multiple physical, chemical, microplastic, and biological contaminants. This will provide a comprehensive understanding of indoor air quality across the city’s socio-economic gradient. Other data collected will include housing types and tenure, ventilation practices, occupant behaviours, time-activity, and airway symptoms. Epidemiological analysis will examine air pollution exposure impacts on children’s respiratory health. The particulate mixture’s relative hazard will be evaluated in toxicity studies based on source profiles and activity patterns of participants, focusing on asthma exacerbation related pathways. The study’s findings will be communicated to participants through co-designed reports and inform evidence-based recommendations for reducing indoor air pollution in London and urban areas worldwide. By raising awareness and providing actionable insights, WellHome seeks to contribute to global efforts to improve the health and well-being of vulnerable communities.

24 April 2026 in Biomolecules
Verified
Journal Article
Open access
PDF file
SFShane Fitzgerald
Shane Fitzgerald
LHLinda Holland
Linda Holland
MFMelissa Finnegan
Melissa Finnegan
KFKellie Fortune
Kellie Fortune
BCBrid Cooney
Brid Cooney
AMAoife Morrin
Aoife Morrin
Infections of chronic wounds are a major healthcare burden worldwide and can lead to poor health outcomes such as amputations of limbs and death. Detecting infections early significantly increases the effectiveness of therapeutic interventions. Screening of volatile organic compounds (VOCs) emitted from wound swab samples can potentially serve as a highly specific indicator of infection. Profiling of VOCs from infected and non-infected wounds was carried out. Swab samples were collected from 26 wounds from 23 patients (n = 20 diabetic patients; n = 3 non-diabetic patients). There were 16 wounds sampled that were clinically determined as infected, and 10 as non-infected. Headspace-solid phase microextraction gas chromatography-mass spectrometry (HS-GC-MS) was used to rapidly sample and detect VOCs from the swabs following a short incubation period. A total of 42 compounds were identified and included for analysis. Infected wounds emitted more diverse VOCs compared to non-infected wounds. Higher numbers of compounds with significantly higher abundances were detected from severely infected wounds compared to less severely infected wounds. Abundances of short-chain fatty acids (SCFAs) and branched-chain fatty acids (BCFAs) were found to be the strongest discriminators of infected from non-infected wounds. Further validation is needed, but the results of this pilot study highlight the potential of detecting these compounds as a highly specific and targeted route to predicting or detecting wound infections in the future.

30 September 2021
Verified
Conference Paper
Open access
PDF file
SFShane Fitzgerald
Shane Fitzgerald
TBTom Beattie
Tom Beattie
Background Bacterial meningitis (BM) is rarer in developed countries due to effective immunisation strategies. Distinguishing viral from BM is also challenging. Culture of cerebrospinal fluid (CSF) is the current gold standard for diagnosis, but delays in reporting results remain a problem. The BioFire Film-Array Meningitis/Encephalitis panel, is a laboratory based multiple analyser which offers rapid, simultaneous PCR-based detection of 14 pathogens responsible for CNS infections. The panel includes 6 bacterial targets, HiB, N.Meningitidis, S.Pneumoniae, S.Agalactiae, L.Monocytogenes, and E.Coli K1, as well as 7 viral targets and 1 fungal analyte. This study aims to review the potential utility of this array panel as a rapid diagnostic tool for early detection of bacterial infection of CSF in the Paediatric Emergency Setting. Objectives Our outcome measure was to determine the diagnostic accuracy of the FA-M/E panel in detecting bacterial isolates in children suspected of having Central Nervous System (CNS) infections, compared to standard reference testing (ie specific laboratory PCR testing or bacterial culture) as reported in the literature. Methods A literature review was performed to identify papers which identified true positive (TP) bacterial isolates (as confirmed by reference testing) detected by the FA-M/E panel in children with suspected BM. Studies published in English between January 2013 and December 2020 were included. Results Of 1995 abstract titles screened for suitability, 8 papers met inclusion criteria. In the 8 studies identified, 256 positive results from 1249 CSF samples tested using FA-M/E technology. Of the positive analyses, 50 (19.5%) were bacterial and 206 (80.5%) were viral/fungal pathogens. 41/50 (82%) bacterial isolates were TP and 6/50 (12%) False Positives (FP) and 3 unconfirmed by reference tests. The bacterial analytes detected include S.Pneumonia 19 (15 TP, 2 FP, 2 unconfirmed) S.Agalactiae 13 (11 TP, 2 FP), E.Coli K1 13 (11TP, 1 FP, 1 unconfirmed), HiB 3 (2 TP, 1 FP), N. Meningitidis 1 (1 TP), L. Monocytogenes 1 (1 TP). 41/50 (82%) bacterial isolates were TP’s confirmed by reference testing, 6/50 (12%) were FP and 3/50 (6%) were unconfirmed by reference testing. Conclusions The FA-M/E panel can detect 6 common bacterial organisms in the CSF with a TP rate of 82% and a FP rate of 12%. The PCR panels ability to rapidly identify CNS pathogens within 60 minutes makes it a useful diagnostic tool in emergency settings. However five out of eight studies included were retrospective and as a result clinical data may had been lost, some samples were retrospectively tested after 2 years, thus we cannot determine the exact impact the FA-M/E would have on clinical outcomes. Due to study design or insufficient CSF volume, many samples did not undergo adjudicatory testing to validate FA-M/E panel results. The FA-M/E panel and rapid PCR panels are feasible adjuncts to conventional testing but larger studies in different settings are required before they can replace current practice.

Verified
Journal Article
Open access
PDF file
HWHolly Mia Walder
Holly Mia Walder
SFShane Fitzgerald
Shane Fitzgerald
LBLeon Barron
Leon Barron
IMIan Stanley Mudway
Ian Stanley Mudway
Understanding indoor and outdoor airborne organic mixtures, including semi-volatile organic compounds (sVOCs), remains challenging as quantitative monitoring is often costly and difficult to scale across buildings and individuals. Here we present a low-cost, miniaturised passive sampler-based methodology for static and wearable deployment to generate time-integrated chemical fingerprints and source prioritisation. New sampler devices containing replicate 9 mm sorbent discs (Tenax® TA and/or polydimethylsiloxane) were deployed for 28 days in indoor (kitchen, bedroom) and outdoor (roadside) environments and worn by five participants; extracts were analysed by liquid extraction and gas chromatography–mass spectrometry (GC-MS) using conservative, transparent criteria for tentative compound identification. Across the household deployments, 52 compounds met inclusion criteria and distinct room-specific and outdoor chemical signatures were observed. Wearable deployments also produced differentiable chemical profiles, with greater similarity among co-inhabitants, but still could differentiate co-habitant activities based on exposure. These results demonstrate the feasibility of using miniature passive samplers to obtain reproducible, information-rich profiles that can help discriminate environments and exposure scenarios.