Ludovico La Grutta

Prof. Dr. Ludovico La Grutta

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2016 in European Journal of Radiology
Verified
Journal Article
Closed access
Domenico AlbanoDomenico Albano
Domenico Albano
CPCaterina Patti
Caterina Patti
LGLudovico La Grutta
Ludovico La Grutta
FAFrancesco Agnello
Francesco Agnello
EGEmanuele Grassedonio
Emanuele Grassedonio
MGMassimo Galia
Massimo Galia

Verified
Journal Article
Open access
PDF file
Filippo CademartiriFilippo Cademartiri
Filippo Cademartiri
Antonella MeloniAntonella Meloni
Antonella Meloni
Laura PistoiaLaura Pistoia
Laura Pistoia
GDGiulia Degiorgi
Giulia Degiorgi
ACAlberto Clemente
Alberto Clemente
EMErica Maffei
Erica Maffei
The photon-counting detector (PCD) is a new computed tomography detector technology (photon-counting computed tomography, PCCT) that provides substantial benefits for cardiac and coronary artery imaging. Compared with conventional CT, PCCT has multi-energy capability, increased spatial resolution and soft tissue contrast with near-null electronic noise, reduced radiation exposure, and optimization of the use of contrast agents. This new technology promises to overcome several limitations of traditional cardiac and coronary CT angiography (CCT/CCTA) including reduction in blooming artifacts in heavy calcified coronary plaques or beam-hardening artifacts in patients with coronary stents, and a more precise assessment of the degree of stenosis and plaque characteristic thanks to its better spatial resolution. Another potential application of PCCT is the use of a double-contrast agent to characterize myocardial tissue. In this current overview of the existing PCCT literature, we describe the strengths, limitations, recent applications, and promising developments of employing PCCT technology in CCT.

1 September 2016 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
Domenico AlbanoDomenico Albano
Domenico Albano
LGLudovico La Grutta
Ludovico La Grutta
EGEmanuele Grassedonio
Emanuele Grassedonio
CPCaterina Patti
Caterina Patti
RLRoberto Lagalla
Roberto Lagalla
MGMassimo Galia
Massimo Galia

13 July 2017 in British Journal of Radiology
Verified
Journal Article
Closed access
MGMassimo Galia
Massimo Galia
Domenico AlbanoDomenico Albano
Domenico Albano
ABAlberto Bruno
Alberto Bruno
AAAntonino Agrusa
Antonino Agrusa
GRGiorgio Romano
Giorgio Romano
RLRoberto Lagalla
Roberto Lagalla
The widespread use of abdominal imaging techniques has increased the detection of solid renal masses over the past years. Imaging plays a crucial role in the management and surveillance and in determining which lesions need treatment. The “classical angiomyolipoma” is the only benign solid renal mass that can be characterized with confidence by imaging through the detection of a fat-containing lesion without calcifications. There is a large overlap of imaging features between benign and malignant renal masses that often makes difficult a correct characterization of these lesions. In this review, we discuss the imaging features of the main solid renal masses that may suggest a likely benign diagnosis.

20 August 2009 in La radiologia medica
Verified
Journal Article
Closed access
PDF file
LGLudovico La Grutta
Ludovico La Grutta
GRG. Runza
G. Runza
GRGiuseppe Lo Re
Giuseppe Lo Re
MGMassimo Galia
Massimo Galia
VAV. Alaimo
V. Alaimo
MMM. Midiri
M. Midiri

1 June 2016 in British Journal of Radiology
Verified
Journal Article
Closed access
LGLudovico La Grutta
Ludovico La Grutta
PTPatrizia Toia
Patrizia Toia
AFAlfonso Farruggia
Alfonso Farruggia
Domenico AlbanoDomenico Albano
Domenico Albano
EGEmanuele Grassedonio
Emanuele Grassedonio
MMMassimo Midiri
Massimo Midiri
Objectives:The aim of the study was to compare epicardial adipose tissue (EAT) characteristics assessed with coronary calcium score (CS) and CT coronary angiography (CTCA) image datasets.Methods:In 76 patients (mean age 59±13 years) who underwent CS and CTCA due to suspected coronary artery disease (CAD), EAT was quantified in terms of density (HU), thickness, and volume. The EAT volume was extracted with a semiautomatic software.Results:A moderate correlation was found between EAT density in CS and CTCA image datasets (-100±19HU vs. -70±24HU, p0.05, r=0.76). The EAT volume resulted 122±50 cm3 in CS and 86±40 cm3 in CTCA (Δ=30%, p<0.05, r=0.92). After adjustment for post-contrast EAT attenuation difference (Δ=30HU), the volume was 101±47 cm3 (Δ=17%, p<0.05, r=0.92). Based on EAT volume median values, no differences were found between groups with...