James Thomas Moulton

Dr. James Thomas Moulton


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Barry LavineBarry Lavine
Barry Lavine
NKNecati Kaval
Necati Kaval
LOLeah Oxenford
Leah Oxenford
MKMariya Kim
Mariya Kim
KDKaushalya Sharma Dahal
Kaushalya Sharma Dahal
Richard A. BunceRichard A. Bunce
Richard A. Bunce
Swellable polymer microspheres that respond to pH were prepared by free radical dispersion polymerization using N-isopropylacrylamide (NIPA), N,N′-methylenebisacrylamide (MBA), 2,2-dimethoxy-2-phenylacetylphenone, N-tert-butylacrylamide (NTBA), and a pH-sensitive functional comonomer (acrylic acid, methacrylic acid, ethacrylic acid, or propacrylic acid). The diameter of the microspheres was between 0.5 and 1.0 μm. These microspheres were cast into hydrogel membranes prepared by mixing the pH-sensitive swellable polymer particles with aqueous polyvinyl alcohol (PVA) solutions followed by crosslinking with glutaric dialdehyde for use as pH sensors. Large changes in the turbidity of the PVA membrane were observed as the pH of the buffer solution in contact with the membrane was varied. These changes were monitored by UV–visible absorbance spectroscopy. Polymer swelling of many NIPA copolymers was reversible and independent of the ionic strength of the buffer solution in contact with the membrane. Both the degree of swelling and the apparent pKa of the polymer microspheres increased with temperature. Furthermore, the apparent pKa of the polymer particles could be tuned to respond sharply to pH in a broad range (pH 4.0–7.0) by varying the amount of crosslinker (MBA) and transition temperature modifier (NTBA), and the amount, pKa, and hydrophobicity of the pH-sensitive functional comonomer (alkyl acrylic acid) used in the formulation. Potential applications of these polymer particles include fiber optic pH sensing where the pH-sensitive material can be immobilized on the distol end of an optical fiber.

22 March 2025 in Molecules
Verified
Journal Article
Open access
PDF file
JMJames Thomas Moulton
James Thomas Moulton
DBDavid Bruce
David Bruce
Richard A. BunceRichard A. Bunce
Richard A. Bunce
MKMariya Kim
Mariya Kim
LSLeah Oxenford Snyder
Leah Oxenford Snyder
Barry LavineBarry Lavine
Barry Lavine
Copolymers of N-isopropylacrylamide (NIPA) and alkyl acrylic acids that swell and shrink in response to pH were prepared by dispersion polymerization at 35 °C using N-isopropylacrylamide (transduction monomer), methylenebisacrylamide (crosslinker), 2-dimethoxy-2-phenyl-acetophenone (initiator), N-tert-butylacrylamide (transition temperature modifier), and acrylic acid, methacrylic acid, ethacrylic acid, and propacrylic acid (functional comonomer). The diameter of the microspheres of the copolymer varied between 0.5 µm and 1.0 µm. These microspheres were cast into hydrogel membranes prepared by mixing the pH-sensitive swellable polymer particles with aqueous polyvinyl alcohol solutions followed by crosslinking the polyvinyl alcohol with glutaric dialdehyde for use as pH sensors. Large changes in the turbidity of the polyvinyl alcohol membrane monitored using a Cary 6000 UV–visible absorbance spectrometer were observed as the pH of the buffer solution in contact with the membrane was varied. Polymer swelling was reversible for many of these NIPA-based copolymers. The buffer capacity, ionic strength, pH, and temperature of the buffer solution in contact with the membrane were systematically varied to provide an in-depth pH profile of each copolymer. A unique aspect of this study was the investigation of the response of the NIPA-based polymers to changes in the pH of the solution in contact with the membrane at low buffer concentrations (0.5 mM). The response rate and the reversibility of polymer swelling even at low buffer capacity suggest that NIPA-based copolymers can be coupled to an optical fiber for pH sensing in the environment. We envision using these polymers to monitor rising acidity levels in the ocean due to water that has become enriched in carbon dioxide that endangers shell-building organisms by reducing the amount of carbonate available to them.